Your browser doesn't support javascript.
loading
A Copper-Based Biosensor for Dual-Mode Glucose Detection.
Li, Kai; Xu, Xiaoyu; Liu, Wanshan; Yang, Shouzhi; Huang, Lin; Tang, Shuai; Zhang, Ziyue; Wang, Yuning; Chen, Fangmin; Qian, Kun.
Afiliación
  • Li K; Department of Urology, Tianjin Third Central Hospital Affiliated to Nankai University, Tianjin, China.
  • Xu X; State Key Laboratory for Oncogenes and Related Genes, School of Biomedical Engineering, Institute of Medical Robotics and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
  • Liu W; Division of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
  • Yang S; State Key Laboratory for Oncogenes and Related Genes, School of Biomedical Engineering, Institute of Medical Robotics and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
  • Huang L; Division of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
  • Tang S; State Key Laboratory for Oncogenes and Related Genes, School of Biomedical Engineering, Institute of Medical Robotics and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
  • Zhang Z; Division of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
  • Wang Y; Department of Clinical Laboratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Chen F; Department of Urology, Tianjin Third Central Hospital Affiliated to Nankai University, Tianjin, China.
  • Qian K; State Key Laboratory for Oncogenes and Related Genes, School of Biomedical Engineering, Institute of Medical Robotics and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
Front Chem ; 10: 861353, 2022.
Article en En | MEDLINE | ID: mdl-35444996
Glucose is a source of energy for daily activities of the human body and is regarded as a clinical biomarker, due to the abnormal glucose level in the blood leading to many endocrine metabolic diseases. Thus, it is indispensable to develop simple, accurate, and sensitive methods for glucose detection. However, the current methods mainly depend on natural enzymes, which are unstable, hard to prepare, and expensive, limiting the extensive applications in clinics. Herein, we propose a dual-mode Cu2O nanoparticles (NPs) based biosensor for glucose analysis based on colorimetric assay and laser desorption/ionization mass spectrometry (LDI MS). Cu2O NPs exhibited excellent peroxidase-like activity and served as a matrix for LDI MS analysis, achieving visual and accurate quantitative analysis of glucose in serum. Our proposed method possesses promising application values in clinical disease diagnostics and monitoring.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Front Chem Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Front Chem Año: 2022 Tipo del documento: Article País de afiliación: China