Your browser doesn't support javascript.
loading
Clinical performance of a smartphone-based low vision aid.
Yeo, Joon Hyung; Bae, Seon Ha; Lee, Seung Hyeun; Kim, Kyoung Woo; Moon, Nam Ju.
Afiliación
  • Yeo JH; Department of Ophthalmology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Republic of Korea.
  • Bae SH; Department of Ophthalmology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
  • Lee SH; Department of Ophthalmology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
  • Kim KW; Department of Ophthalmology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
  • Moon NJ; Department of Ophthalmology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea. njmoon@cau.ac.kr.
Sci Rep ; 12(1): 10752, 2022 06 24.
Article en En | MEDLINE | ID: mdl-35750770
ABSTRACT
Real-time digital image processing to optimally enhance low vision is now realizable with recent advances in personal computers. This study aimed to evaluate the efficacy of a wearable smartphone-based low vision aid (LVA) with customizable vision enhancement in patients with visual impairment. We recruited 35 subjects with visual impairment and who were literate and cognitively capable. The subjects completed a training session and were provided a smartphone-based LVA for a 4-week use. Visual functions including binocular best-corrected distance, intermediate, and near visual acuities; reading performance (reading speed and accuracy); and facial recognition performance were measured at baseline and after 4-weeks use. All subjects also completed the Low Vision Quality of Life (LVQOL) Questionnaire. Thirty-four subjects (mean age, 43.82 ± 15.06 years) completed the study. Significant improvements in binocular best-corrected distance, intermediate, and near visual acuities were observed after smartphone-based LVA use (all p < 0.001). Reading accuracy and facial recognition performance also improved significantly (p = 0.009 and p < 0.001, respectively), but reading speed did not. LVQOL scores significantly improved after 4 weeks of use in subjects aged < 40 years (p = 0.024), but not in subjects aged ≥ 40 years (p = 0.653). Ocular and non-ocular adverse events were infrequent and resolved when the device was removed. The smartphone-based LVA with customizable vision enhancement could provide clinically significant improvements in the visual function of patients with visual impairment and was generally well tolerated. This study suggests that the smartphone-based LVA would be beneficial for visual rehabilitation.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Baja Visión Límite: Adult / Humans / Middle aged Idioma: En Revista: Sci Rep Año: 2022 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Baja Visión Límite: Adult / Humans / Middle aged Idioma: En Revista: Sci Rep Año: 2022 Tipo del documento: Article