Effect of Thermocycling on Shear Bond Strength of PEEK-A Comparative Study of Resin Luting Cements: An In-Vitro Study.
Thapaswini, Yekula; Chary, Nukalamarri O B P; Pardeshi, Kshitij V; Chitumalla, Rajkiran; Cherukuri, Sai A.
Afiliación
  • Nikitha; Department of Prosthodontics, Sri Sai College of Dental Surgery, Vikarabad, Telangana, India.
  • Thapaswini Y; Department of Prosthodontics, Sri Sai College of Dental Surgery, Vikarabad, Telangana, India.
  • Chary NOBP; Department of Prosthodontics, Meghana Institute of Dental Sciences, Nizamabad, Telangana, India.
  • Pardeshi KV; Senior Lecturer, Department of Periodontics, SMBT Institute of Dental Sciences and Research, Nashik, Maharashtra, India.
  • Chitumalla R; Senior Lecture, Department of Prosthodontics King Saud Bin Abdulaziz University for Health Sciences, King Abdullah International Medical Research Center, Riyadh, Saudi Arabia.
  • Cherukuri SA; Department of BDS, Mamata Dental College, Khammam, Telangana, India.
J Pharm Bioallied Sci ; 14(Suppl 1): S679-S682, 2022 Jul.
Article en En | MEDLINE | ID: mdl-36110741
ABSTRACT

Introduction:

Thermocycling is an in-vitro process; it may affect the bonding strength between tooth and resin which is depending upon the adhesive system. Aim and

Objectives:

To evaluate and compare the thermocycling effect on shear bond strength of RelyX Unicem and G-CEM Linkace to polyether ether ketone (PEEK) surface. Materials and

Methods:

A total of 40 PEEK disk-shaped specimens were fabricated with dimensions of 10 × 3 mm and randomly allocated into two groups. Group A was cemented with Rely X Unicem material and Group B was cemented with G-CEM Linkace. About 10 specimens from each group were thermocycled 500 times at 5°C and 55°C. By applying force at the speed of 1 mm/min using a universal testing machine, shear bond strength was measured.

Results:

The mean bond strength was compared using paired t test. There was a significant difference even before and after thermocycling.

Conclusion:

In this experiment, Shear bond strength (SBS) of G-CEM Linkace showed more even before and after thermocycling when compared to RelyX. Also bond strengths of two cements decreased after thermocycling.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: J Pharm Bioallied Sci Año: 2022 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: J Pharm Bioallied Sci Año: 2022 Tipo del documento: Article País de afiliación: India