Your browser doesn't support javascript.
loading
A high-power long lifetime beam dump for the Thomson scattering diagnostic system in the XuanLong-50 experiment.
Liu, J H; Li, S J; Li, H Y; Xie, Q F; Bai, R H; Bo, X K; Deng, B H.
Afiliación
  • Liu JH; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China and ENN Science and Technology Development Co., Ltd., Langfang 065001, China.
  • Li SJ; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China and ENN Science and Technology Development Co., Ltd., Langfang 065001, China.
  • Li HY; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China and ENN Science and Technology Development Co., Ltd., Langfang 065001, China.
  • Xie QF; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China and ENN Science and Technology Development Co., Ltd., Langfang 065001, China.
  • Bai RH; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China and ENN Science and Technology Development Co., Ltd., Langfang 065001, China.
  • Bo XK; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China and ENN Science and Technology Development Co., Ltd., Langfang 065001, China.
  • Deng BH; Hebei Key Laboratory of Compact Fusion, Langfang 065001, China and ENN Science and Technology Development Co., Ltd., Langfang 065001, China.
Rev Sci Instrum ; 93(9): 093505, 2022 Sep 01.
Article en En | MEDLINE | ID: mdl-36182501
ABSTRACT
The Energy iNNovation's XuanLong-50 is a spherical torus experiment with up to 10 s plasma operation duration. A 3 J/50 Hz pulsed laser is used in the Thomson scattering diagnostic system that is developed to measure the time evolutions of plasma electron temperature and density profiles. The expected laser pulse number is about 7.5 × 106/year with a power load of 150 W. To meet at least 1-year lifetime requirement, a Chevron type beam dump with polished molybdenum plates is designed and fabricated, which absorbs the laser beam energy in a 3D structure to reduce the laser fluence deposited on the material surface. To prevent the backscattered stray light from interfering with the Thomson scattering measurements, a 7.5 m beam path with folding mirrors is set between the beam dump and the plasma scattering volumes. Details of the beam dump design procedure including the laser beam profile control, multi-pulse laser damage threshold, heat dissipation, Zemax modeling, folding mirror selection, and beam path enclosure are presented together with the testing results.

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: China