Your browser doesn't support javascript.
loading
Custom Triflange Acetabular Components For Catastrophic Bone Loss: Minimum 5-Year Results.
Alexander, Jacob S; Lombardi, Adolph V; Berend, Keith R; Morris, Michael J; Adams, Joanne B; Crawford, David A.
Afiliación
  • Alexander JS; JIS Orthopedics, New Albany, Ohio.
  • Lombardi AV; JIS Orthopedics, New Albany, Ohio.
  • Berend KR; JIS Orthopedics, New Albany, Ohio.
  • Morris MJ; JIS Orthopedics, New Albany, Ohio.
  • Adams JB; JIS Orthopedics, New Albany, Ohio.
  • Crawford DA; JIS Orthopedics, New Albany, Ohio.
J Arthroplasty ; 38(7): 1330-1334, 2023 07.
Article en En | MEDLINE | ID: mdl-36708935
ABSTRACT

INTRODUCTION:

Custom acetabular components are an increasingly utilized reconstructive option in total hip arthroplasty for catastrophic bone loss and acetabular failure. The purpose of this study was to determine the survivorship of such components for reconstruction due to catastrophic bone loss at a minimum 5-year follow-up.

METHODS:

From August 2003 to July 2016, 64 patients (66 hips) underwent acetabular reconstruction with custom triflange components. All hips were classified as Paprosky 3B or 3C. Harris hip scores were analyzed. Overall survivorship was determined by survival analysis.

RESULTS:

Seventeen patients (18 hips) died prior to returning for 5-year follow-up. One presumed living patient was lost to contact, yielding a cohort of 46 patients (47 hips) who had minimum 5-year follow-up. The mean age was 65 years (range, 46 to 85), mean body mass index was 29.4 (range, 18 to 45), and 72% were women. Mean follow-up was 8 years (range, 5 to 16). There were 3 revisions of the triflange device (6.4%) due to infection. Survivorship to end point of triflange removal for any reason was 94.1% (95% confidence interval ±3.4%) at a mean of 16 years. In the overall series (n = 66), there were 9 (13.6%) additional reoperations as follows 5 incision and debridements, one open reduction internal fixation, two stem revisions for periprosthetic femoral fracture, and one head revision. Harris hip scores improved significantly from a mean of 41 points preoperatively to 64 points postoperatively.

CONCLUSIONS:

Custom acetabular triflange components represent a highly effective tool in a surgeon's armamentarium. These devices are extremely helpful in managing catastrophic bone loss and have a good mean 16-year survival.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Observational_studies / Prognostic_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Observational_studies / Prognostic_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2023 Tipo del documento: Article