Your browser doesn't support javascript.
loading
LIQ HD (Lick Instance Quantifier Home Cage Device): An Open-Source Tool for Recording Undisturbed Two-Bottle Drinking Behavior in a Home Cage Environment.
Petersen, Nicholas; Adank, Danielle N; Raghavan, Ritika; Winder, Danny G; Doyle, Marie A.
Afiliación
  • Petersen N; Vanderbilt Brain Institute, Vanderbilt University School of Medicine, Nashville, TN 37232.
  • Adank DN; Vanderbilt Center for Addiction Research, Vanderbilt University School of Medicine, Nashville, TN 37232.
  • Raghavan R; Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN 37232.
  • Winder DG; Vanderbilt Brain Institute, Vanderbilt University School of Medicine, Nashville, TN 37232.
  • Doyle MA; Vanderbilt Center for Addiction Research, Vanderbilt University School of Medicine, Nashville, TN 37232.
eNeuro ; 10(4)2023 04.
Article en En | MEDLINE | ID: mdl-36997312
ABSTRACT
Investigation of rodent drinking behavior has provided insight into drivers of thirst, circadian rhythms, anhedonia, and drug and ethanol consumption. Traditional methods of recording fluid intake involve weighing bottles, which is cumbersome and lacks temporal resolution. Several open-source devices have been designed to improve drink monitoring, particularly for two-bottle choice tasks. However, beam-break sensors lack the ability to detect individual licks for bout microstructure analysis. Thus, we designed LIQ HD (Lick Instance Quantifier Home cage Device) with the goal of using capacitive sensors to increase accuracy and analyze lick microstructure, building a device compatible with ventilated home cages, increasing scale with prolonged undisturbed recordings, and creating a design that is easy to build and use with an intuitive touchscreen graphical user interface. The system tracks two-bottle choice licking behavior in up to 18 rodent cages, or 36 single bottles, on a minute-to-minute timescale controlled by a single Arduino microcontroller. The data are logged to a single SD card, allowing for efficient downstream analysis. LIQ HD accuracy was validated with sucrose, quinine, and ethanol two-bottle choice tasks. The system measures preference over time and changes in bout microstructure, with undisturbed recordings tested up to 7 d. All designs and software are open-source to allow other researchers to build on the system and adapt LIQ HD to their animal home cages.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Conducta Animal / Consumo de Bebidas Alcohólicas Límite: Animals Idioma: En Revista: ENeuro Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Conducta Animal / Consumo de Bebidas Alcohólicas Límite: Animals Idioma: En Revista: ENeuro Año: 2023 Tipo del documento: Article