Your browser doesn't support javascript.
loading
Predictors of pacing-induced cardiomyopathy detection and outcomes demonstration after conduction system pacing upgrade on patients with long-term persistent atrial fibrillation.
Wang, Nan; Ma, Pei-Pei; Jing, Zhao-Meng; Chen, Ying; Jia, Jing-Jing; Zhao, Fu-Lu; Zhao, Yan-Ni; Xiao, Xian-Jie; Li, Guo-Cao; Yang, Yi-Heng; Ma, Cheng-Ming; Gao, Lian-Jun; Xia, Yun-Long; Yang, Yan-Zong; Dong, Ying-Xue.
Afiliación
  • Wang N; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Ma PP; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Jing ZM; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Chen Y; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Jia JJ; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Zhao FL; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Zhao YN; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Xiao XJ; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Li GC; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Yang YH; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Ma CM; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Gao LJ; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Xia YL; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Yang YZ; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Dong YX; Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
Pacing Clin Electrophysiol ; 46(7): 684-692, 2023 07.
Article en En | MEDLINE | ID: mdl-37345321
ABSTRACT

OBJECTIVE:

To identify the predictors of pacing-induced cardiomyopathy (PICM) and illustrate the safety and feasibility of conduction system pacing (CSP) upgrade on patients with long-term persistent atrial fibrillation (AF).

METHODS:

All patients with long-term persistent AF and normal left ventricular ejection fraction (LVEF) ≥50% were consecutively enrolled from January 2008 to December 2017, and all the patients with atrioventricular block (AVB) and high right ventricular pacing (RVP) percentage of at least 40%. The predictors of PICM were identified, and patients with PICM were followed up for at least 1 year regardless of CSP upgrade. Cardiac performances and lead outcomes were investigated in all patients before and after CSP upgrade.

RESULTS:

The present study included 139 patients, out of which 37 (26.62%) developed PICM, resulting in a significant decrease in the left ventricular ejection fraction (LVEF) from 56.11 ± 2.56% to 38.10 ± 5.81% (p< .01). The median duration for the development of PICM was 5.43 years. Lower LVEF (≤52.50%), longer paced QRS duration (≥175 ms), and higher RVP percentage (≥96.80%) were identified as independent predictors of PICM. Furthermore, the morbidity of PICM progressively increased with an increased number of predictors. The paced QRS duration (183.90 ± 22.34 ms vs. 136.57 ± 20.71 ms, p < .01), LVEF (39.35 ± 2.71% vs. 47.50 ± 7.43%, p < .01), and left ventricular end-diastolic diameter (LVEDD) (55.53 ± 5.67 mm vs. 53.20 ± 5.78 mm, p = .03) improved significantly on patients accepting CSP upgrade. CSP responses and complete reverse remodeling (LVEF ≥50% and LVEDD < 50 mm) were detected in 80.95% (17/21) and 42.9% (9/21) of patients. The pacing threshold (1.52 ± 0.78 V/0.4 ms vs. 1.27 ± 0.59 V/0.4 ms, p = .16) was stable after follow-up.

CONCLUSION:

PICM is very common in patients with long-term persistent AF, and CSP upgrade was favorable for better cardiac performance in this patient population.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Fibrilación Atrial / Cardiomiopatías Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Pacing Clin Electrophysiol Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Fibrilación Atrial / Cardiomiopatías Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Pacing Clin Electrophysiol Año: 2023 Tipo del documento: Article País de afiliación: China