Design of High-Precision Parallel AWG Demodulation System.
Jiao, Yunjing; Lin, Qijing; Yao, Kun; Zhao, Na; Xian, Dan; Zhang, Fuzheng; Meng, Qingzhi; Tian, Bian; Jiang, Zhuangde.
Afiliación
  • Jiao Y; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Lin Q; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Yao K; School of Mechanical and Manufacturing Engineering, Xiamen Institute of Technology, Xiamen 361021, China.
  • Zhao N; Shandong Laboratory of Advanced Materials and Green Manufacturing at Yantai, Yantai 264000, China.
  • Xian D; Bright Stone Industrial Technology Research Institute, Yantai 265503, China.
  • Zhang F; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Meng Q; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Tian B; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Jiang Z; State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
Micromachines (Basel) ; 14(9)2023 Aug 25.
Article en En | MEDLINE | ID: mdl-37763825
Here, we present a high-precision demodulation method that supports the arrayed waveguide grating (AWG) system, which includes a 1 × 8 AWG as the primary filter with a 0.5 nm channel spacing and a 1 × 4 AWG as the auxiliary filter with a 1 nm channel spacing. The high precision is achieved through an innovative method of decoupling three channels, involving two adjacent channels of the primary filter and one channel of the secondary auxiliary filter. Simulation results show that the AWGs have a good transmission spectrum with crosstalk below -24.8 dB, non-uniformities below 0.8 dB, insertion loss below -3.7 dB, 3 dB bandwidth of 0.25 nm, and 10 dB bandwidth of 0.43 nm. The interrogation precision can reach 8 pm, with a dynamic range of 0.4 nm, corresponding to a single FBG.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Micromachines (Basel) Año: 2023 Tipo del documento: Article País de afiliación: China