Your browser doesn't support javascript.
loading
Establishment of real-time fluorescence and visual LAMP for rapid detection of Escherichia coli O157:H7 and kits construction.
Wang, Zuwei; Cui, Xinping; Hu, Antuo; Lu, Zhaoxin; Meng, Fanqiang; Zhou, Libang; Bie, Xiaomei.
Afiliación
  • Wang Z; Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China.
  • Cui X; Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China.
  • Hu A; Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China.
  • Lu Z; Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China.
  • Meng F; Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China.
  • Zhou L; Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China.
  • Bie X; Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China.
Lett Appl Microbiol ; 76(11)2023 Nov 01.
Article en En | MEDLINE | ID: mdl-37863833
Escherichia coli O157:H7 is a common pathogenic bacterium in food and water that can pose a threat to human health. The aim of this study was to develop loop-mediated isothermal amplification (LAMP) method for the detection of E. coli O157:H7 in food based on the specific gene Ecs_2840 and to construct rapid detection kits based on the established methods. Specifically, we established two methods of real-time fluorescent LAMP (RT-LAMP) and visual LAMP with calcein as an indicator. In pure bacterial culture, the cell sensitivity and genomic sensitivity of the RT-LAMP kit were 8.8 × 100 CFU ml-1 and 4.61 fg µl-1, respectively. The sensitivity of the visual LAMP kit was 2.35 × 100 CFU ml-1 and 4.61 fg µl-1. Both kits had excellent specificity and anti-interference performance. In addition, milk inoculated with 2.26 × 100 CFU ml-1E. coli O157:H7 could be detected within the reaction time after enrichment for 3 h. The results showed that the LAMP kits were rapid, sensitive, and specific for the detection of E. coli O157:H7 in food and had good application prospects in food safety surveillance.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Escherichia coli O157 Límite: Humans Idioma: En Revista: Lett Appl Microbiol Asunto de la revista: MICROBIOLOGIA Año: 2023 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Escherichia coli O157 Límite: Humans Idioma: En Revista: Lett Appl Microbiol Asunto de la revista: MICROBIOLOGIA Año: 2023 Tipo del documento: Article