BACKGROUND: Despite the potential benefits of ethanol infusion into the vein of Marshall (EIVOM) for atrial fibrillation (AF) ablation, concerns about its reversible and unpredictable effects persist. OBJECTIVE: To assess the effectiveness of EIVOM in the vein of Marshall (VOM) with collateral veins (CVs) during mitral isthmus and AF ablation. METHODS: We included 142 AF patients. EIVOM was performed before radiofrequency ablation, and low-voltage areas (<0.5 mV) were measured before, immediately after, and 1 h after EIVOM. RESULTS: Among the 142 patients, 93 (65%) underwent EIVOM, and among these, 35 (37%) were found to have CVs. In the VOM with CVs group, areas with low voltage measured 0 (0-1.85) cm2 before EIVOM, 6.9 (4.1-11.2) cm2 immediately after EIVOM, and 5.7 (3.5-10.6) cm2 1 h after EIVOM. Conversely, in the group designated as VOM without CVs-from which the nine leakage cases were excluded-the areas measured 0 (0-1.35) cm2 , 5.5 (2.6-11.8) cm2 , and 4.7 (1.8-13.5) cm2 at the respective time points. MI line block was fully achieved in 89% (31/35) of cases in the VOM with CVs group and 88% (44/49) in the VOM without CVs groups (p = .94). There was no significant difference in the outcome of AF ablation between these groups (log-rank p = .73). Additionally, no significant difference was observed between EIVOM (+) and EIVOM (-) groups (log-rank p = .59). CONCLUSION: EIVOM effectively creates MI line block, and its beneficial effects are sustained for at least 1 h after the procedure despite the low-voltage areas showing a slight reduction in size.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Venas Pulmonares / Fibrilación Atrial / Ablación por Catéter / Ablación por Radiofrecuencia Límite: Humans Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Venas Pulmonares / Fibrilación Atrial / Ablación por Catéter / Ablación por Radiofrecuencia Límite: Humans Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón