Your browser doesn't support javascript.
loading
Biosensing with Surface-Charge-Modulated Graphene Field-Effect Transistors beyond Nonlinear Electrolytic Screening.
Ushiba, Shota; Nakano, Tomomi; Shinagawa, Ayumi; Miyakawa, Naruto; Kato, Tadashi; Yofu, Katsuyuki; Ono, Takao; Kanai, Yasushi; Tani, Shinsuke; Kimura, Masahiko; Matsumoto, Kazuhiko.
Afiliación
  • Ushiba S; Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan.
  • Nakano T; Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan.
  • Shinagawa A; Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan.
  • Miyakawa N; Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan.
  • Kato T; Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan.
  • Yofu K; Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan.
  • Ono T; Osaka University, Ibaraki, Osaka 567-0047, Japan.
  • Kanai Y; International Center for Synchrotron Radiation Innovation Smart, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai 980-8577, Japan.
  • Tani S; Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan.
  • Kimura M; Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan.
  • Matsumoto K; Osaka University, Ibaraki, Osaka 567-0047, Japan.
ACS Omega ; 8(51): 49270-49277, 2023 Dec 26.
Article en En | MEDLINE | ID: mdl-38162780
ABSTRACT
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits the sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and nonfunctionalized GFETs into a chip and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Screening_studies Idioma: En Revista: ACS Omega Año: 2023 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Screening_studies Idioma: En Revista: ACS Omega Año: 2023 Tipo del documento: Article País de afiliación: Japón