Your browser doesn't support javascript.
loading
Preoperative computed tomography-imaging with patient-specific computer simulation in transcatheter aortic valve implantation: Design and rationale of the GUIDE-TAVI trial.
Hegeman, Romy R M J J; van Ginkel, Dirk-Jan; Laengle, Severin; Timmers, Leo; Rensing, Benno J W M; de Kroon, Thomas L; Sonker, Uday; Kelder, Johannes C; Mach, Markus; Andreas, Martin; Swaans, Martin J; Ten Berg, Jurriën M; Klein, Patrick.
Afiliación
  • Hegeman RRMJJ; Department of Cardiothoracic Surgery, Sint Antonius Hospital, Nieuwegein, The Netherlands; Department of Cardiothoracic Surgery, Amsterdam University Medical Center, Amsterdam, the Netherlands. Electronic address: r.hegeman@antoniusziekenhuis.nl.
  • van Ginkel DJ; Department of Cardiology, Sint Antonius Hospital, Nieuwegein, The Netherlands.
  • Laengle S; Department of Cardiothoracic Surgery, Medical University of Vienna, Vienna, Austria.
  • Timmers L; Department of Cardiology, Sint Antonius Hospital, Nieuwegein, The Netherlands.
  • Rensing BJWM; Department of Cardiology, Sint Antonius Hospital, Nieuwegein, The Netherlands.
  • de Kroon TL; Department of Cardiothoracic Surgery, Sint Antonius Hospital, Nieuwegein, The Netherlands.
  • Sonker U; Department of Cardiothoracic Surgery, Sint Antonius Hospital, Nieuwegein, The Netherlands.
  • Kelder JC; Department of Epidemiology, Sint Antonius Hospital, Nieuwegein, The Netherlands.
  • Mach M; Department of Cardiothoracic Surgery, Medical University of Vienna, Vienna, Austria; Department of Cardiovascular Surgery, Heart Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Andreas M; Department of Cardiothoracic Surgery, Medical University of Vienna, Vienna, Austria.
  • Swaans MJ; Department of Cardiology, Sint Antonius Hospital, Nieuwegein, The Netherlands.
  • Ten Berg JM; Department of Cardiology, Sint Antonius Hospital, Nieuwegein, The Netherlands; Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands.
  • Klein P; Department of Cardiothoracic Surgery, Sint Antonius Hospital, Nieuwegein, The Netherlands; Department of Cardiothoracic Surgery, Amsterdam University Medical Center, Amsterdam, the Netherlands.
Am Heart J ; 269: 158-166, 2024 03.
Article en En | MEDLINE | ID: mdl-38163616
ABSTRACT

BACKGROUND:

Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI.

METHODS:

The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life.

CONCLUSIONS:

The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.
Asunto(s)

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Estenosis de la Válvula Aórtica / Prótesis Valvulares Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Humans Idioma: En Revista: Am Heart J Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Estenosis de la Válvula Aórtica / Prótesis Valvulares Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Humans Idioma: En Revista: Am Heart J Año: 2024 Tipo del documento: Article