Your browser doesn't support javascript.
loading
Three-dimensional volume rendering ultrasound for assessing placenta accreta spectrum severity and discriminating it from simple scar dehiscence.
Adu-Bredu, Theophilus K; Ridwan, Robert; Aditiawarman, Aditiawarman; Ariani, Grace; Collins, Sally L; Aryananda, Rozi A.
Afiliación
  • Adu-Bredu TK; Nuffield Department of Women's and Reproductive Health, University of Oxford, Oxford, United Kingdom (Mr Adu-Bredu and Prof Collins).
  • Ridwan R; Maternal Fetal Medicine, Obstetrics and Gynecology Department, Dr Soetomo Academic General Hospital, Universitas Airlangga, Surabaya, Indonesia (Dr Ridwan, Dr Aditiawarman, and Dr Aryananda).
  • Aditiawarman A; Maternal Fetal Medicine, Obstetrics and Gynecology Department, Dr Soetomo Academic General Hospital, Universitas Airlangga, Surabaya, Indonesia (Dr Ridwan, Dr Aditiawarman, and Dr Aryananda).
  • Ariani G; Anatomical Pathology Department, Dr Soetomo Academic General Hospital, Universitas Airlangga, Surabaya, Indonesia (Dr Ariani).
  • Collins SL; Nuffield Department of Women's and Reproductive Health, University of Oxford, Oxford, United Kingdom (Mr Adu-Bredu and Prof Collins).
  • Aryananda RA; Department of Obstetrics and Gynaecology, Erasmus, University Medical Center, Rotterdam, The Netherlands (Dr Aryananda). Electronic address: rozi.odi@gmail.com.
Am J Obstet Gynecol MFM ; 6(4): 101321, 2024 Apr.
Article en En | MEDLINE | ID: mdl-38460827
ABSTRACT

BACKGROUND:

Prenatal ultrasound discrimination between placenta accreta spectrum and scar dehiscence with underlying nonadherent placenta is challenging both prenatally and intraoperatively, which often leads to overtreatment. In addition, accurate prenatal prediction of surgical difficulty and morbidity in placenta accreta spectrum is difficult, which precludes appropriate multidisciplinary planning. The advent of advanced 3-dimensional volume rendering and contrast enhancement techniques in modern ultrasound systems provides a comprehensive prenatal assessment, revealing details that are not discernible in traditional 2-dimensional imaging.

OBJECTIVE:

This study aimed to evaluate the use of 3-dimensional volume rendering ultrasound techniques in determining the severity of placenta accreta spectrum and distinguishing between placenta accreta spectrum and scar dehiscence with underlying nonadherent placenta. STUDY

DESIGN:

A prospective, cohort study was conducted between July 2022 and July 2023 in the fetal medicine unit of Dr Soetomo Academic General Hospital, Surabaya, Indonesia. All pregnant individuals with anterior low-lying placenta or placenta previa with a previous caesarean section who were referred with suspicion of placenta accreta spectrum were consented and screened using the standardised 2-dimensional and Doppler ultrasound imaging. Additional 3-dimensional volumes were obtained from the sagittal section of the uterus with a filled urinary bladder. These were analyzed by rotating the region of interest to be perpendicular to the uterovesical interface. The primary outcomes were the clinical and histologic severity in the cases of placenta accreta spectrum and correct diagnosis of dehiscence with nonadherent placenta underneath. The strength of association between ultrasound and clinical outcomes was determined. Multivariate logistic regression analyses and diagnostic testing of accuracy were used to analyze the data.

RESULTS:

A total of 70 patients (56 with placenta accreta spectrum and 14 with scar dehiscence) were included in the analysis. Multivariate logistic regression of all 2-dimensional and 3-dimensional signs revealed the 3-dimensional loss of clear zone (P<.001) and the presence of bridging vessels on 2-dimensional Doppler ultrasound (P=.027) as excellent predictors in differentiating scar dehiscence and placenta accreta spectrum. The 3-dimensional loss of clear zone demonstrated a high diagnostic accuracy with an area under the curve of 0.911 (95% confidence interval, 0.819-1.002), with a sensitivity of 89.3% (95% confidence interval, 78.1-95.97%) and specificity of 92.9% (95% confidence interval, 66.1-99.8%). The presence of bridging vessels on 2-dimensional Doppler demonstrated an area under the curve of 0.848 (95% confidence interval, 0.714-0.982) with a sensitivity of 91.1% (95% confidence interval, 80.4-97.0%) and specificity of 78.6% (95% confidence interval, 49.2-95.3%). A subgroup analysis among the placenta accreta spectrum group revealed that the presence of a 3-dimensional disrupted bladder serosa with obliteration of the vesicouterine space was associated with vesicouterine adherence (P<.001).

CONCLUSION:

Three-dimensional volume rendering ultrasound is a promising tool for effective discrimination between scar dehiscence with underlying nonadherent placenta and placenta accreta spectrum. It also shows potential in predicting the clinical severity with urinary bladder involvement in cases of placenta accreta spectrum.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Placenta Accreta / Ultrasonografía Prenatal / Cicatriz / Imagenología Tridimensional Límite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Am J Obstet Gynecol MFM Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Placenta Accreta / Ultrasonografía Prenatal / Cicatriz / Imagenología Tridimensional Límite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Am J Obstet Gynecol MFM Año: 2024 Tipo del documento: Article