Your browser doesn't support javascript.
loading
Rapid Detection of Measles Virus Using Reverse Transcriptase/Recombinase Polymerase Amplification Coupled with CRISPR/Cas12a and a Lateral Flow Detection: A Proof-of-Concept Study.
Pinchon, Elena; Henry, Steven; Leon, Fanny; Fournier-Wirth, Chantal; Foulongne, Vincent; Cantaloube, Jean-François.
Afiliación
  • Pinchon E; Pathogénèse et Contrôle des Infections Chroniques et Emergentes, Etablissement Français du Sang, Université de Montpellier, Inserm, 34184 Montpellier, France.
  • Henry S; Pathogénèse et Contrôle des Infections Chroniques et Emergentes, Etablissement Français du Sang, Université de Montpellier, Inserm, 34184 Montpellier, France.
  • Leon F; Pathogénèse et Contrôle des Infections Chroniques et Emergentes, Etablissement Français du Sang, Université de Montpellier, Inserm, 34184 Montpellier, France.
  • Fournier-Wirth C; Pathogénèse et Contrôle des Infections Chroniques et Emergentes, Etablissement Français du Sang, Université de Montpellier, Inserm, 34184 Montpellier, France.
  • Foulongne V; Pathogénèse et Contrôle des Infections Chroniques et Emergentes, Etablissement Français du Sang, Université de Montpellier, Inserm, 34184 Montpellier, France.
  • Cantaloube JF; Pathogénèse et Contrôle des Infections Chroniques et Emergentes, Etablissement Français du Sang, Université de Montpellier, Inserm, 34184 Montpellier, France.
Diagnostics (Basel) ; 14(5)2024 Feb 29.
Article en En | MEDLINE | ID: mdl-38472989
ABSTRACT
The measles virus is highly contagious, and efforts to simplify its diagnosis are essential. A reverse transcriptase/recombinase polymerase amplification assay coupled with CRISPR/Cas12a and an immunochromatographic lateral flow detection (RT-RPA-CRISPR-LFD) was developed for the simple visual detection of measles virus. The assay was performed in less than 1 h at an optimal temperature of 42 °C. The detection limit of the assay was 31 copies of an RNA standard in the reaction tube. The diagnostic performances were evaluated on a panel of 27 measles virus RT-PCR-positive samples alongside 29 measles virus negative saliva samples. The sensitivity and specificity were 96% (95% CI, 81-99%) and 100% (95% CI, 88-100%), respectively, corresponding to an accuracy of 98% (95% CI, 94-100%; p < 0.0001). This method will open new perspectives in the development of the point-of-care testing diagnosis of measles.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Diagnostics (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Diagnostics (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Francia