Your browser doesn't support javascript.
loading
Long-term follow-up of total hip arthroplasty using polyethylene-ceramic composite (sandwich) liner.
Rodríguez-Pérez, Daniel; Carnaval, Thiago; Rodríguez, Marcos-Del-Carmen; Coscujuela-Maña, Antonio; Agulló, José-Luis; Videla, Sebastián.
Afiliación
  • Rodríguez-Pérez D; Orthopaedic Surgery and Traumatology Department, Bellvitge University Hospital, L'Hospitalet de Llobregat, Barcelona, Spain.
  • Carnaval T; Clinical Research Support Unit (HUB-IDIBELL: Bellvitge University Hospital & Bellvitge Biomedical Research Institute), Clinical Pharmacology Department, Bellvitge University Hospital, L'Hospitalet de Llobregat, Barcelona, Spain.
  • Rodríguez MD; Pharmacology Unit, Department of Pathology and Experimental Therapeutics, School of Medicine and Health Sciences, IDIBELL, University of Barcelona, L'Hospitalet de Llobregat, Barcelona, Spain.
  • Coscujuela-Maña A; Orthopaedic Surgery and Traumatology Department, Bellvitge University Hospital, L'Hospitalet de Llobregat, Barcelona, Spain.
  • Agulló JL; Orthopaedic Surgery and Traumatology Department, Bellvitge University Hospital, L'Hospitalet de Llobregat, Barcelona, Spain.
  • Videla S; Orthopaedic Surgery and Traumatology Department, Bellvitge University Hospital, L'Hospitalet de Llobregat, Barcelona, Spain.
Hip Int ; 34(4): 467-475, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38529883
ABSTRACT

INTRODUCTION:

Ceramic-on-ceramic bearings have been widely used since their introduction in the 1970s. First-generation ceramics have very high fracture (breakage) rates. To overcome this, in the 1990s, modular cotyloid insert designs were developed, consisting of a ceramic and polyethylene composite (sandwich-type) liner; however, high implant fracture rates were observed in the medium term. We aimed to estimate the cumulative incidences of revision surgery (implant failure) and implant failure due to fractures, survival rates (time-to-revision surgery and time-to-fracture), and the long-term clinical and radiological outcomes in our series.

METHODS:

This was an observational, longitudinal, ambispective, single-centre study based on patients who underwent primary total hip arthroplasty (THA) using a sandwich-type liner (Cerasul), only available in our tertiary hospital between January 1999 and December 2002. Cumulative incidences were estimated and the 95% confidence interval (95% CI) was calculated. The Kaplan-Meier method was used to assess the time-to-revision surgery and time-to-fracture.

RESULTS:

54 patients (49 men) were included, accounting for 59 sandwich-type linear implants. The mean (range) age was 47.4 (22-57) years. The primary THA indications were osteoarthritis (28 patients), osteonecrosis (14), childhood pathology sequelae (11), and inflammatory arthritis (6). The cumulative incidence of revision surgery by implants was 8.5% (5/59, 95% CI, 3.5-19.2%), 9.3% by patients (5/54, 95% CI, 4.0-19.9%), and 5.1% by implant fractures (3/59, 95%CI, 1.7-13.9%). The median (Interquartile Range, IQR) time-to-revision surgery was 158 (72.5-161) months, and the time to fracture was 182 (138-215) months. All primary THAs had good clinical and long-term survival outcomes. All implants had signs of solid fixation.

CONCLUSIONS:

After a 20-year follow-up period, the polyethylene-ceramic sandwich-type liner showed a long survival rate and low cumulative incidence of implant fracture; however, implant fractures remain the main complication. Orthopaedic surgeons should be aware that some patients still have this type of prosthesis and must be capable of responding quickly if a fracture occurs.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Diseño de Prótesis / Reoperación / Falla de Prótesis / Cerámica / Artroplastia de Reemplazo de Cadera / Polietileno / Prótesis de Cadera Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Hip Int Año: 2024 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Diseño de Prótesis / Reoperación / Falla de Prótesis / Cerámica / Artroplastia de Reemplazo de Cadera / Polietileno / Prótesis de Cadera Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Hip Int Año: 2024 Tipo del documento: Article País de afiliación: España