Design and Control of Upper Limb Rehabilitation Training Robot Based on a Magnetorheological Joint Damper.
Zhu, Jintao; Hu, Hongsheng; Zhao, Wei; Yang, Jiabin; Ouyang, Qing.
Afiliación
  • Zhu J; College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China.
  • Hu H; College of Information Science and Engineering, Jiaxing University, Jiaxing 314001, China.
  • Zhao W; College of Information Science and Engineering, Jiaxing University, Jiaxing 314001, China.
  • Yang J; College of Information Science and Engineering, Jiaxing University, Jiaxing 314001, China.
  • Ouyang Q; College of Information Science and Engineering, Jiaxing University, Jiaxing 314001, China.
Micromachines (Basel) ; 15(3)2024 Feb 22.
Article en En | MEDLINE | ID: mdl-38542548
ABSTRACT
In recent years, rehabilitation robots have been developed and used in rehabilitation training for patients with hemiplegia. In this paper, a rehabilitation training robot with variable damping is designed to train patients with hemiplegia to recover upper limb function. Firstly, a magnetorheological joint damper (MR joint damper) is designed for the rehabilitation training robot, and its structural design and dynamic model are tested theoretically and experimentally. Secondly, the rehabilitation robot is simplified into a spring-damping system, and the rehabilitation training controller for human movement is designed. The rehabilitation robot dynamically adjusts the excitation current according to the feedback speed and human-machine interaction torque, so that the rehabilitation robot always outputs a stable torque. The magnetorheological joint damper acts as a clutch to transmit torque safely and stably to the robot joint. Finally, the upper limb rehabilitation device is tested. The expected torque is set to 20 N, and the average value of the output expected torque during operation is 20.02 N, and the standard deviation is 0.635 N. The output torque has good stability. A fast (0.5 s) response can be achieved in response to a sudden motor speed change, and the average expected output torque is 20.38 N and the standard deviation is 0.645 N, which can still maintain the stability of the output torque.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Micromachines (Basel) Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Micromachines (Basel) Año: 2024 Tipo del documento: Article País de afiliación: China