Your browser doesn't support javascript.
loading
Inconsistent False Lumen Enhancement Predicts Late Aortic Events After Hemiarch Replacement in Acute Type A Aortic Dissection.
Nishida, Hidefumi; Nakamura, Ryota; Tamaki, Rihito; Abe, Kohei.
Afiliación
  • Nishida H; Department of Cardiovascular Surgery, St. Luke's International Hospital, Tokyo, Japan. Electronic address: hidefumi226@gmail.com.
  • Nakamura R; Department of Cardiovascular Surgery, St. Luke's International Hospital, Tokyo, Japan.
  • Tamaki R; Department of Cardiovascular Surgery, St. Luke's International Hospital, Tokyo, Japan.
  • Abe K; Department of Cardiovascular Surgery, St. Luke's International Hospital, Tokyo, Japan.
Am J Cardiol ; 221: 77-83, 2024 06 15.
Article en En | MEDLINE | ID: mdl-38636625
ABSTRACT
The impact of inconsistent enhancement within the patent false lumen on the occurrence of late aortic events remains uncertain. We enrolled 55patients who exhibited a patent false lumen after hemiarch replacement. The Hounsfield unit (HU) measurements in the patent false lumen were obtained at 2 specific locations the aortic arch (a) and the descending aorta (b). The false lumen HU score was calculated as the absolute value of 1 - a/b, representing the discrepancy in HUs within the patent false lumen. We investigated the cut-off value of the false lumen HU score with the receiver operating characteristics curve to predict the incidence of late aortic events. We divided the patients based on the cut-off value and compared the cumulative incidence of the late aortic events. The analysis of the receiver operating characteristics curve showed that the cut-off value of the false lumen HU score was 0.345. Based on this cut-off value, we divided them into 2 groups Group A (score <0.345, n = 26) and Group B (score ≥0.345, n = 29). The baseline characteristics were similar between the 2 groups. The cumulative incidence of the late aortic events was significantly lower in Group A (7.8% at 5 years) than in Group B (39.9% at 5 years) (p = 0.02). The false lumen HU score might be useful to predict the incidence of late aortic events after hemiarch replacement.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Aneurisma de la Aorta Torácica / Disección Aórtica Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Aneurisma de la Aorta Torácica / Disección Aórtica Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Año: 2024 Tipo del documento: Article