Your browser doesn't support javascript.
loading
Optimized scoring of end-to-end dosimetry audits for passive motion management - A simulation study using the IROC thorax phantom.
Burton, Alex; Gaudreault, Mathieu; Hardcastle, Nicholas; Lye, Jessica; Beveridge, Sabeena; Kry, Stephen F; Franich, Rick.
Afiliación
  • Burton A; Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), Yallambie, Victoria 3085, Australia; Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Austr
  • Gaudreault M; Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Australia.
  • Hardcastle N; Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Australia; Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522, Australia.
  • Lye J; Olivia Newton John Cancer Research and Wellness Centre, Heidelberg 3084, Australia.
  • Beveridge S; Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), Yallambie, Victoria 3085, Australia.
  • Kry SF; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; Imaging and Radiation Oncology Core, Houston, TX 77054, USA.
  • Franich R; Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; School of Science, RMIT University, Melbourne, Victoria 3000, Australia.
Phys Med ; 121: 103363, 2024 May.
Article en En | MEDLINE | ID: mdl-38653119
ABSTRACT
Dosimetry audits for passive motion management require dynamically-acquired measurements in a moving phantom to be compared to statically calculated planned doses. This study aimed to characterise the relationship between planning and delivery errors, and the measured dose in the Imaging and Radiation Oncology Core (IROC) thorax phantom, to assess different audit scoring approaches. Treatment plans were created using a 4DCT scan of the IROC phantom, equipped with film and thermoluminescent dosimeters (TLDs). Plans were created on the average intensity projection from all bins. Three levels of aperture complexity were explored dynamic conformal arcs (DCAT), low-, and high-complexity volumetric modulated arcs (VMATLo, VMATHi). Simulated-measured doses were generated by modelling motion using isocenter shifts. Various errors were introduced including incorrect setup position and target delineation. Simulated-measured film doses were scored using gamma analysis and compared within specific regions of interest (ROIs) as well as the entire film plane. Positional offsets were estimated based on isodoses on the film planes, and point doses within TLD contours were compared. Motion-induced differences between planned and simulated-measured doses were evident even without introduced errors Gamma passing rates within target-centred ROIs correlated well with error-induced dose differences, while whole film passing rates did not. Isodose-based setup position measurements demonstrated high sensitivity to errors. Simulated point doses at TLD locations yielded erratic responses to introduced errors. ROI gamma analysis demonstrated enhanced sensitivity to simulated errors compared to whole film analysis. Gamma results may be further contextualized by other metrics such as setup position or maximum gamma.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Tórax / Planificación de la Radioterapia Asistida por Computador / Fantasmas de Imagen / Movimiento Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Tórax / Planificación de la Radioterapia Asistida por Computador / Fantasmas de Imagen / Movimiento Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2024 Tipo del documento: Article