Your browser doesn't support javascript.
loading
Stability indicating high performance thin layer chromatography method development and validation for quantitative determination of tetracycline hydrochloride in tetracycline hydrochloride active pharmaceutical ingredient (API) and its dosage forms.
Gashaw, Misganaw; Layloff, Thomas; Hymete, Ariaya; Ashenef, Ayenew.
Afiliación
  • Gashaw M; Department of Pharmaceutical Chemistry and Pharmacognosy, School of Pharmacy, College of Health Sciences, Addis Ababa University, P.O. Box. 1176, Addis Ababa, Ethiopia.
  • Layloff T; Department of Pharmacy, College of Health Sciences, Debre Markos University, P.O. Box. 269, Debre Markos, Ethiopia.
  • Hymete A; , Granite City, USA.
  • Ashenef A; Department of Pharmaceutical Chemistry and Pharmacognosy, School of Pharmacy, College of Health Sciences, Addis Ababa University, P.O. Box. 1176, Addis Ababa, Ethiopia.
BMC Chem ; 18(1): 82, 2024 Apr 24.
Article en En | MEDLINE | ID: mdl-38659043
ABSTRACT
Simple, quick, cost-effective, and environmentally friendly analytical methods for quality assurance and control roles for different medicines, including Tetrcyclines, are most significantly needed. Also, different thin layer chromatography (TLC)-based methods for tetracycline identification exist, but high performance thin layer chromatography methods based on modern state- of- the art equipment are still nonexistent. Thus, in this study, analytical method development and verification were done by high performance thin layer chromatography (HPTLC) (using an automated equipment model) using glass plates coated with silica gel 60 F254 after treating with 10% Na2EDTA. Validation was carried out according to International Council for Harmonization (ICH) guidelines. A mobile phase formed from ethyl acetate, acetonitrile, methanol, and 1% aqueous ammonia in the composition of 4.419.6106 volume to volume ratio (V/V) was used. Rf value, percentage recoveries, linearity ranges, limit of detection (LOD), and limit of quantitation (LOQ) for the developed HPTLC method were 0.28, 100.83-106.25%, 160-560 ng/band (r2 values of 0.9999), 31.9 ng/band, and 96.7 ng/band, respectively. The results of the sample assays conducted using the new method and the United States Pharmacopoeia (USP) high performance liquid chromatography (HPLC) method were 91.59% to 108.3% and 90.83% to 102.85%, respectively. The F test for the aforementioned methods was 2.01, which is smaller than the tabulated F value of 5.05 with 5 degrees of freedom at a 95% confidence range, proving that the newly developed HPTLC and HPLC pharmacopoeial methods can be used interchangeably.The newly developed HPTLC method is easy, economical, specific, accurate, and roboust, thus it can be employed in a range of settings that require quality control and assurance activities of tetracycline hydrochloride (TC-HCl) in bulk and ointment dosage forms.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: BMC Chem Año: 2024 Tipo del documento: Article País de afiliación: Etiopia

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: BMC Chem Año: 2024 Tipo del documento: Article País de afiliación: Etiopia