Your browser doesn't support javascript.
loading
Construction of an immunosensor based on Cys/Au@TiO2 modification for the detection of liver cancer marker PIVKA-II.
Gong, Lvhong; Wu, Shengxi; Liu, Junjie; Zhang, Mingjun; Zhuang, Jinghao; Xu, Doudou.
Afiliación
  • Gong L; School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing 400054, China.
  • Wu S; School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing 400054, China. Electronic address: sxwu2004@cqut.edu.cn.
  • Liu J; School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing 400054, China.
  • Zhang M; Laboratory Department of Chongqing Jiulongpo District People's Hospital, Chongqing, 400050, China.
  • Zhuang J; Department of Physics and Energy, Chongqing University of Technology, Chongqing 400054, China.
  • Xu D; NMPA Key Laboratory for Quality Monitoring of Narcotic Drugs and Psychotropic Substances, Chongqing Institute for Food and Drug Control, Chongqing, 401121, China. Electronic address: xudoudou@cqifdc.org.cn.
Talanta ; 275: 126082, 2024 Aug 01.
Article en En | MEDLINE | ID: mdl-38677167
ABSTRACT
An ultrasensitive immunosensor of Cys/Au@TiO2 based on disposable screen-printed electrodes (SPE) for PIVKA-II detection for hepatocellular carcinoma (HCC) diagnosis was developed by utilizing Cystine (Cys) and nanocomposite Au@TiO2. Firstly, HAuCl4 underwent a reduction reaction with NaBH4, then Au nanoparticles were coated onto TiO2 nanoparticles. Followed, Cys/Au@TiO2 was formed through self-assembly of cysteine to allow the monoclonal antibody of abnormal thrombospondin to bound to the amino group on the surface of the composite by covalent bonding. The mechanism is to determine the changes in the current of the sensor caused by the specific binding of the abnormal prothrombin monoclonal antibody adsorbed by the complex with its antigen. The Cys/Au@TiO2 immunosensor was fully characterized by various analytical approaches and it showed a wide linear testing range of 1-10000 pg mL-1 (R2 = 0.991) and the limit of detection down to 0.77 pg ml-1, with highly sensitivity and specificity. The results showed that the developed immunosensor platform can effectively detect trace amounts of PIVKA-II protein and has potent clinical application for HCC diagnosis.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Titanio / Protrombina / Técnicas Biosensibles / Biomarcadores de Tumor / Cisteína / Oro / Neoplasias Hepáticas Límite: Humans Idioma: En Revista: Talanta Año: 2024 Tipo del documento: Article País de afiliación: China