Improving image quality of sparse-view lung tumor CT images with U-Net.
Ries, Annika; Dorosti, Tina; Thalhammer, Johannes; Sasse, Daniel; Sauter, Andreas; Meurer, Felix; Benne, Ashley; Lasser, Tobias; Pfeiffer, Franz; Schaff, Florian; Pfeiffer, Daniela.
Afiliación
  • Ries A; Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, Garching, 85748, Germany.
  • Dorosti T; Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany.
  • Thalhammer J; Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, Garching, 85748, Germany. tina.dorosti@tum.de.
  • Sasse D; Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany. tina.dorosti@tum.de.
  • Sauter A; Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany. tina.dorosti@tum.de.
  • Meurer F; Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, Garching, 85748, Germany.
  • Benne A; Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany.
  • Lasser T; Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Pfeiffer F; Institute for Advanced Study, Technical University of Munich, 85748, Garching, Germany.
  • Schaff F; Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
  • Pfeiffer D; Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
Eur Radiol Exp ; 8(1): 54, 2024 May 03.
Article en En | MEDLINE | ID: mdl-38698099
ABSTRACT

BACKGROUND:

We aimed to improve the image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determine the best tradeoff between number of views, IQ, and diagnostic confidence.

METHODS:

CT images from 41 subjects aged 62.8 ± 10.6 years (mean ± standard deviation, 23 men), 34 with lung metastasis, 7 healthy, were retrospectively selected (2016-2018) and forward projected onto 2,048-view sinograms. Six corresponding sparse-view CT data subsets at varying levels of undersampling were reconstructed from sinograms using filtered backprojection with 16, 32, 64, 128, 256, and 512 views. A dual-frame U-Net was trained and evaluated for each subsampling level on 8,658 images from 22 diseased subjects. A representative image per scan was selected from 19 subjects (12 diseased, 7 healthy) for a single-blinded multireader study. These slices, for all levels of subsampling, with and without U-Net postprocessing, were presented to three readers. IQ and diagnostic confidence were ranked using predefined scales. Subjective nodule segmentation was evaluated using sensitivity and Dice similarity coefficient (DSC); clustered Wilcoxon signed-rank test was used.

RESULTS:

The 64-projection sparse-view images resulted in 0.89 sensitivity and 0.81 DSC, while their counterparts, postprocessed with the U-Net, had improved metrics (0.94 sensitivity and 0.85 DSC) (p = 0.400). Fewer views led to insufficient IQ for diagnosis. For increased views, no substantial discrepancies were noted between sparse-view and postprocessed images.

CONCLUSIONS:

Projection views can be reduced from 2,048 to 64 while maintaining IQ and the confidence of the radiologists on a satisfactory level. RELEVANCE STATEMENT Our reader study demonstrates the benefit of U-Net postprocessing for regular CT screenings of patients with lung metastasis to increase the IQ and diagnostic confidence while reducing the dose. KEY POINTS • Sparse-projection-view streak artifacts reduce the quality and usability of sparse-view CT images. • U-Net-based postprocessing removes sparse-view artifacts while maintaining diagnostically accurate IQ. • Postprocessed sparse-view CTs drastically increase radiologists' confidence in diagnosing lung metastasis.