[Low-dose CT reconstruction based on high-dimensional partial differential equation projection recovery].
Niu, S; Tang, S; Huang, S; Liang, L; Li, S; Liu, H.
Afiliación
  • Niu S; School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China.
  • Tang S; Ganzhou Key Laboratory of Computational Imaging, Gannan Normal University, Ganzhou 341000, China.
  • Huang S; School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China.
  • Liang L; School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China.
  • Li S; School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China.
  • Liu H; School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(4): 682-688, 2024 Apr 20.
Article en Zh | MEDLINE | ID: mdl-38708501
ABSTRACT

OBJECTIVE:

We propose a low-dose CT reconstruction method using partial differential equation (PDE) denoising under high-dimensional constraints.

METHODS:

The projection data were mapped into a high-dimensional space to construct a high-dimensional representation of the data, which were updated by moving the points in the high-dimensional space. The data were denoised using partial differential equations and the CT image was reconstructed using the FBP algorithm.

RESULTS:

Compared with those by FBP, PWLS-QM and TGV-WLS methods, the relative root mean square error of the Shepp-Logan image reconstructed by the proposed method were reduced by 68.87%, 50.15% and 27.36%, the structural similarity values were increased by 23.50%, 8.83% and 1.62%, and the feature similarity values were increased by 17.30%, 2.71% and 2.82%, respectively. For clinical image reconstruction, the proposed method, as compared with FBP, PWLS-QM and TGV-WLS methods, resulted in reduction of the relative root mean square error by 42.09%, 31.04% and 21.93%, increased the structural similarity values by 18.33%, 13.45% and 4.63%, and increased the feature similarity values by 3.13%, 1.46% and 1.10%, respectively.

CONCLUSION:

The new method can effectively reduce the streak artifacts and noises while maintaining the spatial resolution in reconstructed low-dose CT images.