Fracture Risk Associated with Different Numbers and Combinations of Lumbar Vertebrae: The Manitoba BMD Registry.
J Clin Densitom
; 27(3): 101502, 2024.
Article
en En
| MEDLINE
| ID: mdl-38723458
ABSTRACT
Bone mineral density (BMD) is widely used for assessment of fracture risk. For the lumbar spine, BMD is typically measured from L1-L4 as it provides the largest area for assessment with the best measurement precision. Structural artifact often confounds spine BMD in clinical practice, and the International Society for Clinical Densitometry (ISCD) recommends removing vertebrae with artifact when reporting spine BMD. In its most recent position statements, the ISCD recommended against the use of a single vertebra when reporting spine BMD but stated that further studies should be done. The current analysis was performed to compare the performance of BMD from different numbers and combination of vertebral levels on fracture prediction in a large clinical registry of DXA tests for the Province of Manitoba, Canada. The study population comprised 39,727 individuals aged 40 years and older (mean age 62.7 years, 91.0â¯% female) with baseline DXA after excluding those with evidence of structural artifact. Mean follow-up for ascertaining fracture outcomes was 8.7 years. Area under the curve (AUC) for incident fracture risk stratification was statistically significant regardless of the BMD measurement site or fracture outcome. AUC differences with the various numbers and combinations of vertebral levels including a single vertebral body were small (less than or equal to 0.01). More substantial AUC differences were seen for femoral neck and total hip BMD versus L1-L4 BMD, approaching 0.1 for hip fracture stratification. In summary, we found that using combinations of fewer than 4 vertebrae including individual lumbar vertebrae predicted incident fractures. Importantly, differences between these different combinations were small when compared with L1-L4. Spine BMD was a better predictor of incident spine fracture compared to the hip, whereas the hip was better for hip fracture and overall fracture prediction.
Palabras clave
Texto completo:
1
Base de datos:
MEDLINE
Asunto principal:
Absorciometría de Fotón
/
Densidad Ósea
/
Sistema de Registros
/
Vértebras Lumbares
Límite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
País/Región como asunto:
America do norte
Idioma:
En
Revista:
J Clin Densitom
Asunto de la revista:
ORTOPEDIA
Año:
2024
Tipo del documento:
Article
País de afiliación:
Canadá