Your browser doesn't support javascript.
loading
Usefulness of Impulse Oscillometry in Predicting the Severity of Bronchiectasis.
Choi, Ji Soo; Kwak, Se Hyun; Kim, Min Chul; Seol, Chang Hwan; Heo, Seok-Jae; Kim, Sung Ryeol; Lee, Eun Hye.
Afiliación
  • Choi JS; Division of Pulmonology, Allergy and Critical Care Medicine, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea.
  • Kwak SH; Division of Pulmonology, Allergy and Critical Care Medicine, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea.
  • Kim MC; Division of Pulmonology, Allergy and Critical Care Medicine, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea.
  • Seol CH; Division of Pulmonology, Allergy and Critical Care Medicine, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea.
  • Heo SJ; Division of Biostatistics, Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Kim SR; Division of Pulmonology, Allergy and Critical Care Medicine, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea.
  • Lee EH; Division of Pulmonology, Allergy and Critical Care Medicine, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea.
Tuberc Respir Dis (Seoul) ; 87(3): 368-377, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38783483
ABSTRACT

BACKGROUND:

Bronchiectasis is a chronic respiratory disease that leads to airway inflammation, destruction, and airflow limitation, which reflects its severity. Impulse oscillometry (IOS) is a non-invasive method that uses sound waves to estimate lung function and airway resistance. The aim of this study was to assess the usefulness of IOS in predicting the severity of bronchiectasis.

METHODS:

We retrospectively reviewed the IOS parameters and clinical characteristics in 145 patients diagnosed with bronchiectasis between March 2020 and May 2021. Disease severity was evaluated using the FACED score, and patients were divided into mild and moderate/severe groups.

RESULTS:

Forty-four patients (30.3%) were in the moderate/severe group, and 101 (69.7%) were in the mild group. Patients with moderate/severe bronchiectasis had a higher airway resistance at 5 Hz (R5), a higher difference between the resistance at 5 and 20 Hz (R5-R20), a higher resonant frequency (Fres), and a higher area of reactance (AX) than patients with mild bronchiectasis. R5 ≥0.43, resistance at 20 Hz (R20) ≥0.234, R5-R20 ≥28.3, AX ≥1.02, reactance at 5 Hz (X5) ≤-0.238, and Fres ≥20.88 revealed significant univariable relationships with bronchiectasis severity (p<0.05). Among these, only X5 ≤-0.238 exhibited a significant multivariable relationship with bronchiectasis severity (p=0.039). The receiver operating characteristic curve for predicting moderate- to-severe bronchiectasis of FACED score based on IOS parameters exhibited an area under the curve of 0.809.

CONCLUSION:

The IOS assessed by the disease severity of FACED score can effectively reflect airway resistance and elasticity in bronchiectasis patients and serve as valuable tools for predicting bronchiectasis severity.