Your browser doesn't support javascript.
loading
A novel method to perform morphological measurements on three-dimensional (3D) models of the calcaneus based on computed tomography (CT)-imaging.
Wakker, Alexander M; Van Lieshout, Esther M M; De Boer, A Siebe; Cornelissen, Bart M W; Verhofstad, Michael H J; Van Walsum, Theo; Visser, Jacob J; Van Vledder, Mark G.
Afiliación
  • Wakker AM; Trauma Research Unit, Department of Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • Van Lieshout EMM; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • De Boer AS; Trauma Research Unit, Department of Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • Cornelissen BMW; Trauma Research Unit, Department of Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • Verhofstad MHJ; Department of Oral and Maxillofacial Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • Van Walsum T; Trauma Research Unit, Department of Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • Visser JJ; Biomedical Imaging Group Rotterdam, Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • Van Vledder MG; Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
Quant Imaging Med Surg ; 14(6): 3778-3788, 2024 Jun 01.
Article en En | MEDLINE | ID: mdl-38846290
ABSTRACT

Background:

While current preoperative and postoperative assessment of the fractured and surgically reconstructed calcaneus relies on computed tomography (CT)-imaging, there are no established methods to quantify calcaneus morphology on CT-images. This study aims to develop a semi-automated method for morphological measurements of the calcaneus on three-dimensional (3D) models derived from CT-imaging.

Methods:

Using CT data, 3D models were created from healthy, fractured, and surgically reconstructed calcanei. Böhler's angle (BA) and Critical angle of Gissane (CAG) were measured on conventional lateral radiographs and corresponding 3D CT reconstructions using a novel point-based method with semi-automatic landmark placement by three observers. Intraobserver and interobserver reliability scores were calculated using intra-class correlation coefficient (ICC). In addition, consensus among observers was calculated for a maximal allowable discrepancy of 5 and 10 degrees for both methods.

Results:

Imaging data from 119 feet were obtained (40 healthy, 39 fractured, 40 reconstructed). Semi-automated measurements on 3D models of BA and CAG showed excellent reliability (ICC 0.87-1.00). The manual measurements on conventional radiographs had a poor-to-excellent reliability (ICC 0.22-0.96). In addition, the percentage of consensus among observers was much higher for the 3D method when compared to conventional two-dimensional (2D) measurements.

Conclusions:

The proposed method enables reliable and reproducible quantification of calcaneus morphology in 3D models of healthy, fractured and reconstructed calcanei.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Quant Imaging Med Surg Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Quant Imaging Med Surg Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos