Your browser doesn't support javascript.
loading
Comparison of electrocardiogram and blood pressure recording methods in non-rodent toxicology studies: A retrospective analysis.
Pawluk, Emma; Delaunois, Annie; Gamboa, Bastien; Valentin, Jean-Pierre.
Afiliación
  • Pawluk E; UCB Biopharma SRL, Chemin du Foriest, B-1420 Braine-l'Alleud, Belgium. Electronic address: emma.pawluk@ucb.com.
  • Delaunois A; UCB Biopharma SRL, Chemin du Foriest, B-1420 Braine-l'Alleud, Belgium.
  • Gamboa B; UCB Biopharma SRL, Chemin du Foriest, B-1420 Braine-l'Alleud, Belgium.
  • Valentin JP; UCB Biopharma SRL, Chemin du Foriest, B-1420 Braine-l'Alleud, Belgium.
J Pharmacol Toxicol Methods ; 128: 107537, 2024 Jun 30.
Article en En | MEDLINE | ID: mdl-38955286
ABSTRACT
Our study retrospectively examines 51 non-rodent general toxicology studies conducted over the past 8 years to ascertain the influence of recording methodologies on baseline cardiovascular (CV) parameters and statistical sensitivity. Specifically, our work aims to evaluate the frequency of cardiovascular parameter recording categorized by therapeutic modality and study type, to assess the variability in these parameters based on measurement techniques, and to determine the sample sizes needed for detecting relevant changes in heart rate (HR), blood pressure (BP), and QTc interval in non-human primate (NHP) studies. Results indicate that electrocardiogram (ECG) measurements in dogs and NHP were recorded in 63% of studies, combined with BP recording in 18% of studies, while BP was never recorded alone. Trend analysis reveals a decline in the utilisation of restraint-based methods for ECG measurements post-2017, to the benefit of telemetry-based recordings, particularly Jacketed External Telemetry (JET). There was a marked difference in baseline values, with restraint-based methods showing significantly higher HR and QTc values compared to JET, likely linked to animal stress. Further analysis suggests an unrealistic and unethical sample size requirement in NHP studies for detecting biologically meaningful CV parameter changes using restraint-based methods, while JET methods necessitate significantly smaller sample sizes. This retrospective study indicates a notable shift from snapshots short-duration, restraint-based methods towards telemetry approaches over the recent years, especially with an increased usage of implanted telemetry. The transition contributes to potential consensus within industry or regulatory frameworks for optimal practices in assessing ECG, HR, and BP in general toxicology studies.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: J Pharmacol Toxicol Methods Asunto de la revista: FARMACOLOGIA / TOXICOLOGIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: J Pharmacol Toxicol Methods Asunto de la revista: FARMACOLOGIA / TOXICOLOGIA Año: 2024 Tipo del documento: Article