Your browser doesn't support javascript.
loading
Probe fusion all-optic OCT-PAM dual-mode imaging system for biomedical imaging.
Ding, Ning; Jiang, Huiwen; Xiang, Ben; Yu, Yao; Ji, Cheng; Liu, Jian; Zhao, Yuqian; Luan, Jingmin; Yang, Yanqiu; Wang, Yi; Ma, Zhenhe.
Afiliación
  • Ding N; College of Information Science and Engineering, Northeastern University, Shenyang 110819, China.
  • Jiang H; College of Information Science and Engineering, Northeastern University, Shenyang 110819, China.
  • Xiang B; College of Information Science and Engineering, Northeastern University, Shenyang 110819, China.
  • Yu Y; School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, china.
  • Ji C; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao 066004, China.
  • Liu J; Qinhuangdao Haigang Hospital, Qinhuangdao 066004, China.
  • Zhao Y; School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, china.
  • Luan J; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao 066004, China.
  • Yang Y; School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, china.
  • Wang Y; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao 066004, China.
  • Ma Z; School of Computer and Communication Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Photoacoustics ; 38: 100631, 2024 Aug.
Article en En | MEDLINE | ID: mdl-39055738
ABSTRACT
We proposed a non-contact photoacoustic (PA) detection method using spectral domain optical coherence tomography (SDOCT). Two interference spectrums (A-lines) were acquired before and after the PA excitation with SDOCT. PA signal propagated within the sample causing the vibration. The vibration inner the sample introduced phase change between the acquired two A-lines. Thus, the PA signal can be detected by evaluating the difference in phase between the two A-lines. Based on the method, an OCT-PAM dual-mode imaging system was constructed. In the system, SDOCT served as the detection unit for PAM. Thus, the combination of the two imaging modalities was simplified. Another advantage of the system is that it realizes non-contact all-optic detection, which is attractive for biomedical imaging. Using the system, we imaged phantoms of carbon fibers, asparagus leaves and human hairs. Furthermore, the cortical vasculature of rat was imaged in vivo and the flow status was evaluated quantitatively.
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Photoacoustics Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Idioma: En Revista: Photoacoustics Año: 2024 Tipo del documento: Article