Incidence and risk factors of blood transfusion after total knee arthroplasty: A retrospective nationwide inpatient sample database study.
Heliyon
; 10(14): e34406, 2024 Jul 30.
Article
en En
| MEDLINE
| ID: mdl-39104503
ABSTRACT
Introduction:
Common postoperative complications of total knee arthroplasty (TKA) include blood transfusion. Although risk factors and incidence of blood transfusion have been studied through national databases, the relative impact of each risk factor needs to be synthesized over a longer time period into a new model need to be revised. Material andmethods:
Patient data were extracted from the National Inpatient Sample (NIS), which is the largest hospital care database in the US, and analyse patient data retrospectively from 2010 through 2019. The final data included the patients undergoing TKA. The final analysis assessed the demographics of patients, type of insurance, type of hospital, length of stay (LOS), preoperative comorbidities, total charge, inpatient mortality, medical-surgical postoperative complications.Results:
After extracting data from the NIS database, a total of 1,250,533 patients with TKA were included in the analysis, and the rate of transfusion was 6.60 %. TKA patients who receive blood transfusion had longer LOS (from 2-3 days to 3-4 days), more preoperative comorbidities, higher inpatient mortality rate, and increased total charge (P < 0.001). Moreover, postoperative complications associated with inpatients included sepsis, acute myocardial infarction and shock. Elective admission and private insurance were also regarded as protective factors.Conclusion:
Blood transfusion could bring postoperative complications to patients, which were also linked to health costs and risks. It was also a common preoperative comorbidities for older patients who underwent TKA. Through better blood management strategies, we could reduce patient transfusion rates and improve clinical outcomes.Level of Evidence Diagnostic Level â ¢.
Texto completo:
1
Base de datos:
MEDLINE
Idioma:
En
Revista:
Heliyon
Año:
2024
Tipo del documento:
Article
País de afiliación:
China