Your browser doesn't support javascript.
loading
Rapid detection of ceftriaxone-resistant Salmonella by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry combined with the ratio of optical density.
Fang, Chao; Zhou, Zheng; Zhou, Mingming; Li, Jianping.
Afiliación
  • Fang C; Department of Clinical Laboratory, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, No. 3333 Binsheng road, Hangzhou, Zhejiang Province, China. 6513067@zju.edu.cn.
  • Zhou Z; Department of Clinical Laboratory, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, No. 3333 Binsheng road, Hangzhou, Zhejiang Province, China.
  • Zhou M; Department of Clinical Laboratory, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, No. 3333 Binsheng road, Hangzhou, Zhejiang Province, China.
  • Li J; Department of Clinical Laboratory, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, No. 3333 Binsheng road, Hangzhou, Zhejiang Province, China.
Ann Clin Microbiol Antimicrob ; 23(1): 70, 2024 Aug 07.
Article en En | MEDLINE | ID: mdl-39113073
ABSTRACT

BACKGROUND:

The increased resistance rate of Salmonella to third-generation cephalosporins represented by ceftriaxone (CRO) may result in the failure of the empirical use of third-generation cephalosporins for the treatment of Salmonella infection in children. The present study was conducted to evaluate a novel method for the rapid detection of CRO-resistant Salmonella (CRS).

METHODS:

We introduced the concept of the ratio of optical density (ROD) with and without CRO and combined it with matrix-assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF MS) to establish a new protocol for the rapid detection of CRS.

RESULTS:

The optimal incubation time and CRO concentration determined by the model strain test were 2 h and 8 µg/ml, respectively. We then conducted confirmatory tests on 120 clinical strains. According to the receiver operating characteristic curve analysis, the ROD cutoff value for distinguishing CRS and non-CRS strains was 0.818 [area under the curve 1.000; 95% confidence interval 0.970-1.000; sensitivity 100.00%; specificity 100%; P < 10- 3].

CONCLUSIONS:

In conclusion, the protocol for the combined ROD and MALDI-TOF MS represents a rapid, accurate, and economical method for the detection of CRS.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Salmonella / Infecciones por Salmonella / Ceftriaxona / Pruebas de Sensibilidad Microbiana / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción / Antibacterianos Límite: Humans Idioma: En Revista: Ann Clin Microbiol Antimicrob Asunto de la revista: MICROBIOLOGIA / TERAPIA POR MEDICAMENTOS Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Salmonella / Infecciones por Salmonella / Ceftriaxona / Pruebas de Sensibilidad Microbiana / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción / Antibacterianos Límite: Humans Idioma: En Revista: Ann Clin Microbiol Antimicrob Asunto de la revista: MICROBIOLOGIA / TERAPIA POR MEDICAMENTOS Año: 2024 Tipo del documento: Article País de afiliación: China