Your browser doesn't support javascript.
loading
Study protocol: diagnostic accuracy study comparing Cy-Tb and STANDARD F TB-Feron FIA tests for tuberculosis infection diagnosis in Vietnam.
Nguyen, Han Thi; Vo, Luan Nguyen Quang; Codlin, Andrew; Forse, Rachel; Wingfield, Tom; Sidney, Kristi; MacLean, Emily Lai-Ho; Creswell, Jacob; Kirubi, Beatrice; Davies Forsman, Lina.
Afiliación
  • Nguyen HT; Department of Medicine, Unit of Infectious Disease, Karolinska Institute, Stockholm, Sweden han.nguyen.2@ki.se.
  • Vo LNQ; Friends for International Tuberculosis Relief, Ha Noi, Vietnam.
  • Codlin A; Friends for International TB Relief (FIT), Ho Chi Minh City, Vietnam.
  • Forse R; Department of Global Public Health, Karolinska Institute, Stockholm, Sweden.
  • Wingfield T; Friends for International TB Relief (FIT), Ho Chi Minh City, Vietnam.
  • Sidney K; Department of Global Public Health, Karolinska Institute, Stockholm, Sweden.
  • MacLean EL; Friends for International TB Relief (FIT), Ho Chi Minh City, Vietnam.
  • Creswell J; Department of Global Public Health, The Health and Social Protection Action Research & Knowledge Sharing Network (SPARKS), Karolinska Institutet, Stockholm, Sweden.
  • Kirubi B; Department of Global Public Health, Karolinska Institute, Stockholm, Sweden.
  • Davies Forsman L; Department of International Public Health and Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, UK.
BMJ Open ; 14(8): e085614, 2024 Aug 09.
Article en En | MEDLINE | ID: mdl-39122402
ABSTRACT

INTRODUCTION:

The large reservoir of tuberculosis (TB) infections is one of the main reasons for the persistent incidence of TB. Accurate diagnostic tests are crucial to correctly identify and treat people with TB infection, which is vital to eliminate TB globally. The rdESAT-6 and rCFP-10 (Cy-Tb) injection ('Cy-Tb'), a TB-specific antigen skin test and STANDARD F TB-Feron FIA ('Standard F TB') measuring interferon-gamma by fluorescence immunoassay assay are two novel tools for the diagnosis of TB infection which offer advantages compared with current tests in low-resource settings and reduced costs to both health systems and TB-affected people. The proposed study aims to evaluate the diagnostic accuracy of these two new tests for TB infection diagnosis. METHODS AND

ANALYSIS:

This cross-sectional study aims to assess the diagnostic accuracy for TB infection of the Cy-Tb skin test and Standard F TB assay (investigational tests) compared with the QuantiFERON-TB Gold Plus (QFT-Plus) assay as the immunological reference standard. Three different cohorts of study participants will be recruited at the Vietnam National Lung Hospital adults with bacteriologically confirmed pulmonary TB (n=100), household contacts of people with TB (n=200) and people without TB infection (n=50). All consenting participants will undergo simultaneous testing with Cy-Tb, Standard F TB and QFT-Plus. The primary endpoint is the diagnostic accuracy of the Cy-Tb skin test and Standard F TB assay, expressed as sensitivity and specificity against the reference standard. ETHICS AND DISSEMINATION Ethical approval was granted by the Vietnam National Lung Hospital Institutional Review Board (65/23/CN-HDDD-BVPTU) and the Swedish Ethical Review Authority (Dnr 2023-04271-01). Study results will be disseminated to the scientific community and policymakers through scientific publications. TRIAL REGISTRATION NUMBER NCT06221735.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Tuberculosis / Prueba de Tuberculina / Ensayos de Liberación de Interferón gamma Límite: Adult / Humans País/Región como asunto: Asia Idioma: En Revista: BMJ Open Año: 2024 Tipo del documento: Article País de afiliación: Suecia

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Tuberculosis / Prueba de Tuberculina / Ensayos de Liberación de Interferón gamma Límite: Adult / Humans País/Región como asunto: Asia Idioma: En Revista: BMJ Open Año: 2024 Tipo del documento: Article País de afiliación: Suecia