Your browser doesn't support javascript.
loading
Succinimide-Functionalized Reduced Graphene Oxide Nanosheets: A High-throughput Resistive Sensing Platform for Age-Related Macular Degeneration Biomarker Determination Using Human Tears.
Ghosh, Tanmoya Nemai; Rotake, Dinesh Ramkrushna; Singh, Shiv Govind.
Afiliación
  • Ghosh TN; Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Sangareddy 502284, India.
  • Rotake DR; Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Sangareddy 502284, India.
  • Singh SG; Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Sangareddy 502284, India.
ACS Appl Bio Mater ; 7(9): 6014-6024, 2024 Sep 16.
Article en En | MEDLINE | ID: mdl-39141809
ABSTRACT
Age-related macular degeneration (AMD) is a well-recognized affliction among the elderly, causing vision impairment ranging from blurred vision to complete blindness. This underscores the critical need for accurate, precise, and early detection methods. Herein, we developed a noninvasive, label-free electrical biosensor, constructed on an economical printed circuit board (PCB) substrate, designed specifically for the precise quantification of AMD biomarker complement component III (C3). The hydrothermally reduced graphene oxide (rGO) was deposited between gold-interdigitated microelectrodes, forming a conductive channel. The fabricated C3 biosensor exhibits a low detection limit of 0.4342 ng/mL and an impressive sensitivity of 9.238 ((ΔR/R)/ng.mL-1)/cm2 with a regression coefficient of 0.9815 calibrated within the clinical C3 range of 10-30 ng/mL. This excellent performance is ascribed to the synergistic effects of 1-pyrenebutanoic acid succinimidyl ester (PBASE) linker and conducting properties of rGO as they generate large active sites for higher anti-C3 antibody immobilization, thereby enhancing sensitivity and specificity. Furthermore, the performance of this proposed C3 sensor chip was validated with enzyme-linked immunosorbent assay (ELISA) using five human tear samples exhibiting an outstanding correlation of a regression value of 0.9774. The unparalleled merits of this newly crafted C3 biosensor transcend those of preceding platforms, boasting superior accuracy and precision in quantifying C3 levels in human tears, accelerated operational speed with results attainable within a mere 15 min, cost-effectiveness, and excellent sensitivity.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Succinimidas / Lágrimas / Biomarcadores / Técnicas Biosensibles / Grafito / Degeneración Macular Límite: Humans Idioma: En Revista: ACS Appl Bio Mater Año: 2024 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Succinimidas / Lágrimas / Biomarcadores / Técnicas Biosensibles / Grafito / Degeneración Macular Límite: Humans Idioma: En Revista: ACS Appl Bio Mater Año: 2024 Tipo del documento: Article País de afiliación: India