Your browser doesn't support javascript.
loading
An ultrasensitive electrochemical biosensor with dual-amplification mode and enzyme-deposited silver for detection of miR-205-5p.
Xie, Xixiang; Chen, Chunxia; Chen, Wuchao; Qin, Yujuan; Xiang, Shulin; Jiang, Jiajun; Chen, Xiaoyu; Li, Junjun.
Afiliación
  • Xie X; Department of Pharmacy, The People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi Academy of Medical Sciences, Nanning, 530021, Guangxi, China.
  • Chen C; Department of Pharmacy, The People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi Academy of Medical Sciences, Nanning, 530021, Guangxi, China.
  • Chen W; The People's Hospital of Guangxi Zhuang Autonomous Region & Institute of Hospital Management and Medical Prevention Collaborative Innovation, Guangxi Academy of Medical Sciences, Nanning, 530021, Guangxi, China.
  • Qin Y; Institute of Cardiovascular Sciences, Guangxi Academy of Medical Sciences, Nanning, 530021, Guangxi, China.
  • Xiang S; School of Basic Medicine, Youjiang Medical University for Nationalities, Baise, 533000, Guangxi, China.
  • Jiang J; Research Center of Communicable and Severe Diseases, Guangxi Academy of Medical Sciences, Nanning, 530021, Guangxi, China.
  • Chen X; Department of Intensive Care Unit, The Peoples Hospital of Guangxi Zhuang Autonomous Region, Nanning, 530021, Guangxi, China.
  • Li J; Department of Transplantation, The People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi Academy of Medical Sciences, Nanning, 530021, Guangxi, China.
Mikrochim Acta ; 191(9): 545, 2024 08 19.
Article en En | MEDLINE | ID: mdl-39158763
ABSTRACT
An electrochemical biosensor based on dual-amplified nucleic acid mode and biocatalytic silver deposition was constructed using catalytic hairpin assembly-hybrid chain reaction (CHA-HCR). The electrochemical detection of silver on the electrode by linear sweep voltammetry (LSV) can be utilized to quantitatively measure miR-205-5p since the amount of silver deposited on the electrode is proportional to the target nucleic acid. The current response values exhibit strong linearity with the logarithm of miR-205-5p concentrations ranging from 0.1 pM to 10 µM, and the detection limit is 28 fM. A consistent trend was found in the results of the qRT-PCR and electrochemical biosensor techniques, which were employed to determine the total RNA recovered from cells, respectively. Moreover, the constructed sensor was used to assess miR-205-5p on various cell counts, and the outcomes demonstrated the excellent analytical efficiency of the proposed strategy. The recoveries ranged from 97.85% to 115.3% with RSDs of 2.251% to 4.869% in human serum samples. Our electrochemical biosensor for miR-205-5p detection exhibits good specificity, high sensitivity, repeatability, and stability. It is a potentially useful sensing platform for tumor diagnosis and tumor type identification in clinical settings.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Plata / Técnicas Biosensibles / MicroARNs / Técnicas Electroquímicas / Límite de Detección Límite: Humans Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Plata / Técnicas Biosensibles / MicroARNs / Técnicas Electroquímicas / Límite de Detección Límite: Humans Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: China