Your browser doesn't support javascript.
loading
Anatomical Feasibility of Percutaneous Arteriovenous Fistula Formation in Korea.
Moon, Ki Yoon; Jang, Eun Ju; Lee, Seung Hoon; Han, Hong Suk; Park, Sun Cheol; Kim, Jang Yong; Yun, Sang Seob.
Afiliación
  • Moon KY; Division of Vascular and Transplant Surgery, Department of Surgery, College of Medicine, The Catholic University of Korea, Seocho-gu, Republic of Korea.
  • Jang EJ; Division of Vascular and Transplant Surgery, Department of Surgery, College of Medicine, The Catholic University of Korea, Seocho-gu, Republic of Korea.
  • Lee SH; Division of Vascular and Transplant Surgery, Department of Surgery, College of Medicine, The Catholic University of Korea, Seocho-gu, Republic of Korea.
  • Han HS; Division of Vascular and Transplant Surgery, Department of Surgery, College of Medicine, The Catholic University of Korea, Seocho-gu, Republic of Korea.
  • Park SC; Division of Vascular and Transplant Surgery, Department of Surgery, College of Medicine, The Catholic University of Korea, Seocho-gu, Republic of Korea.
  • Kim JY; Division of Vascular and Transplant Surgery, Department of Surgery, College of Medicine, The Catholic University of Korea, Seocho-gu, Republic of Korea.
  • Yun SS; Division of Vascular and Transplant Surgery, Department of Surgery, College of Medicine, The Catholic University of Korea, Seocho-gu, Republic of Korea.
Vasc Endovascular Surg ; 58(8): 841-846, 2024 Nov.
Article en En | MEDLINE | ID: mdl-39174319
ABSTRACT

INTRODUCTION:

Currently, there are two types of percutaneous arteriovenous fistula (pAVF) formation systems approved by the FDA Ellipsys and WavelinQ. Although these systems are already in use in Europe or the United States, they have not been approved for use in Korea yet. For this reason, this study aimed to check anatomical feasibility of these systems for Korean population prior to their actual use.

METHODS:

Consecutive patients who received ultrasound vein mapping for arteriovenous fistula formation from June 2021 to June 2022 were included. The anatomical feasibility of each system was confirmed according to the manufacturer's instructions for use (IFU).

RESULTS:

Upper extremity ultrasonography was performed for a total of 83 patients to determine their feasibility for pAVF formation. Of these patients, 65.1% were feasible for pAVF formation with appropriate deep communicating vein (DCV) and outflow. Among them, 57.8% were feasible for the Ellipsys system and 54.2% were feasible for the WavelinQ system. Most patients who were infeasible for pAVF formation had a DCV of small size. Ulnar vessels were more suitable than radial vessel for WavelinQ (54.2% vs 33.7%, P-value = .012). The most common reason for not meeting the criteria was a small vein size at the access site.

CONCLUSIONS:

More than half of all patients were feasible for pAVF formation in this study. Ellipsys had a higher feasibility than WavelinQ, although they showed no significant difference in the feasibility. If these devices are imported into Korea, it will be a good opportunity for many patients to reduce the surgical burden and create AVFs more easily through these procedures.
Asunto(s)
Palabras clave

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Derivación Arteriovenosa Quirúrgica / Estudios de Factibilidad / Diálisis Renal / Extremidad Superior Límite: Adult / Aged / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Vasc Endovascular Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Base de datos: MEDLINE Asunto principal: Derivación Arteriovenosa Quirúrgica / Estudios de Factibilidad / Diálisis Renal / Extremidad Superior Límite: Adult / Aged / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Vasc Endovascular Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2024 Tipo del documento: Article