Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Med Genet A ; 176(3): 733-738, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29392821

RESUMO

Congenital Hemidysplasia with Ichthyosiform nevus and Limb Defects (CHILD syndrome) is a rare X-linked dominant genodermatosis caused by mutations in the NAD(P) dependent steroid dehydrogenase-like protein gene. Its defect leads to accumulation of toxic metabolic intermediates upstream from the pathway block and to the deficiency of bulk cholesterol, probably leading to altered keratinocyte membrane function, resulting in the phenotype seen in CHILD syndrome. Symptomatic treatment using emollients and retinoids to reduce scaling has long been used until recently, whereby new therapeutic means based on the pathogenesis-targeted therapy have been developed. We subsequently chose to use the same pathogenesis-based therapy using a 2% cholesterol and 2% lovastatin cream with or without glycolic acid in two of our patients. Improvement in CHILD skin lesions was seen as early as 4 weeks after initiation. The addition of glycolic acid helped improve the penetrance of the cholesterol and lovastatin cream into the thick waxy scales. Our study confirms the efficacy of the pathogenesis-targeted therapy and introduces the possibility of modifying its formula by adding glycolic acid in order to improve the treatment.


Assuntos
Anormalidades Múltiplas/diagnóstico , Anormalidades Múltiplas/genética , Doenças Genéticas Ligadas ao Cromossomo X/diagnóstico , Doenças Genéticas Ligadas ao Cromossomo X/genética , Eritrodermia Ictiosiforme Congênita/diagnóstico , Eritrodermia Ictiosiforme Congênita/genética , Deformidades Congênitas dos Membros/diagnóstico , Deformidades Congênitas dos Membros/genética , 3-Hidroxiesteroide Desidrogenases/genética , Anormalidades Múltiplas/terapia , Biópsia , Criança , Colesterol/administração & dosagem , Feminino , Doenças Genéticas Ligadas ao Cromossomo X/terapia , Humanos , Eritrodermia Ictiosiforme Congênita/terapia , Deformidades Congênitas dos Membros/terapia , Lovastatina/administração & dosagem , Mutação , Fenótipo , Pele/patologia , Resultado do Tratamento
2.
Patient Prefer Adherence ; 18: 531-541, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38444755

RESUMO

Purpose: Typical barriers to venous blood collection for wellness testing include discomfort, time spent, and collection site accessibility. This study assessed individuals' experience, satisfaction, and preference associated with a FDA-cleared blood-collection device, the BD MiniDraw™ Capillary Blood Collection System (BD MiniDraw), in retail locations. Patients and Methods: A total of 113 individuals (≥18 years) with venous blood collection experience were enrolled; 107 completed the study. A pre-collection survey gathered information on demographics and past experiences with healthcare and venous blood collection settings. BD MiniDraw collection was conducted at three retail sites (two pharmacies and one grocery store) by trained healthcare workers using the Babson BetterWay blood testing service model. A follow up survey was performed two weeks later to determine experience with, and preference for, BD MiniDraw in terms of staff professionalism, blood collection location, blood collection time, and staff trustworthiness. Results: Among the 107 participants, 74 (69%) were female and 33 (31%) were male; the mean age was 49 years (range=18-71 years). Sixty-six (62%) participants viewed their prior venipuncture experience as "somewhat" or "very" positive. Following capillary collection, 96 (90%) participants expressed a "somewhat" or "very" positive experience with BD MiniDraw at a retail location. In particular, "very satisfied" responses were given for location (87/107; 81%) and collection time (78/1407; 73%). In a subset of respondents (n=89), those reasons (location and time savings) were most frequent for likelihood of future use. Ninety-nine participants (92%) rated the retail blood collection team as "very" or "extremely" trustworthy. Overall, 90 participants (84%) "strongly preferred" (56/107; 52%), "somewhat preferred" (14/107; 13%), or had "no preference" (20/107; 19%) for BD MiniDraw, compared to traditional venous blood collection. Conclusion: Most participants conveyed a preference for BD MiniDraw, primarily based on the blood collection retail location, perceived time savings, and professionalism and trustworthiness of the staff.

3.
Am J Med Sci ; 368(4): 274-286, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38636653

RESUMO

Blood tests are vital to prevention, diagnosis, and management of chronic diseases. Despite this, it can be challenging to construct a comprehensive view of the clinical importance of blood testing because relevant literature is typically fragmented across different disease areas and patient populations. This lack of collated evidence can also make it difficult for primary care providers to adhere to best practices for blood testing across different diseases and guidelines. Thus, this review article synthesizes the recommendations for, and importance of, blood testing across several common chronic conditions encountered in primary care and internal medicine, including cardiovascular diseases, diabetes mellitus, chronic kidney disease, vitamin D deficiency, iron deficiency, and rheumatoid arthritis. Future research is needed to continue improving chronic disease management through clearer dissemination and awareness of clinical guidelines among providers, and better access to blood testing for patients (e.g., via pre-visit laboratory testing).


Assuntos
Testes Hematológicos , Humanos , Doença Crônica , Testes Hematológicos/métodos , Doenças Cardiovasculares/prevenção & controle , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/sangue , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/sangue , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/terapia , Diabetes Mellitus/sangue , Gerenciamento Clínico
4.
J Immunol Methods ; 534: 113767, 2024 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-39426789

RESUMO

BACKGROUND: Highly efficient clinical laboratories are essential for monitoring many human illnesses. Ampath Laboratory Services, the largest pathology lab in South Africa, analyzes large numbers of peripheral blood samples for CD4 levels yearly. OBJECTIVE: To assess productivity and quality of a newer integrated automated solution, the BD FACSDuet™ Sample Preparation System/BD FACSLyric™ Flow Cytometer using conventional assessment methods and Lean concepts. MATERIALS AND METHODS: This prospective study compared the performance of the BD FACS™ Sample Preparation Assistant [SPA] III and BD FACSCanto™ II Flow Cytometer with the newly introduced integrated system (BD FACSDuet™/BD FACSLyric™). They were validated for accuracy, precision, and external quality assessment. Process mapping and Lean assessment helped identify steps leading to waste. An economic model was developed to characterize workflow and economic impact associated with total daily hands-on time, processing time, and reworks. RESULTS: Strong linear correlation was present between both systems. Precision and accuracy studies revealed that all coefficient of variation (CV)% values were below 20% of allowable limits. External proficiency assessments were within limits. The fully automated workflow of BD FACSDuet™/BD FACSLyric™ permitted better consistency with significantly shorter processing time and batch processing and reduced operator interventions. Lean assessment identified defects with motion, over-processing, waiting, and non-utilized talent. Significant reductions in hands-on and total daily processing time that could increase daily specimen testing efficiency and fewer reworks were associated with the BD FACSDuet™/BD FACSLyric™. Lean improvements translated to significant economic savings associated with operator costs and unnecessary reagent consumption. CONCLUSION: BD FACSDuet™/BD FACSLyric™ is an accurate, reliable, and cost-effective fully automated system for high-volume flow cytometry labs that perform T-cell enumeration using a single-platform and single-tube approach.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA