Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 56(2): 209-215, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29891434

RESUMO

OBJECTIVES: This article reports mid-term results of 41 patients treated by the stent assisted balloon induced intimal disruption and relamination (STABILISE) technique for acute type B aortic dissection. METHODS: Between November 2011 and November 2017, 41 patients (10 male; median age 50 years) underwent proximal descending aortic stent grafting plus stent assisted balloon induced intimal disruption of the thoraco-abdominal aorta for acute type B aortic dissection. Serial computed tomography angiography was used to assess aortic remodelling. RESULTS: There were no intra-procedural complications. Fifteen branch arteries supplied by the false lumen were stented (9% of the visceral branch arteries). The thirty day incidence of death, stroke, and paralysis/visceral ischaemia was 2% (n = 1), 0%, 5% (n = 2), and 2% (n = 1) respectively. During a median follow up of 12 months (range 1-168) eight patients (20%) required re-intervention. Primary visceral stent patency was 93% (n = 14). No aortic related deaths occurred. On the most recent computed tomography angiogram, complete false lumen obliteration and aortic remodelling was obtained in all patients at the thoraco-abdominal level, and in 39% (n = 16) at the unstented infrarenal aorto-iliac level. The maximum aortic diameter increased in only two patients (5%) at the unstented infrarenal level. CONCLUSION: To obtain immediate and durable thoraco-abdominal aortic remodelling in acute type B dissections, the STABILISE technique is safe and reproducible while not compromising the patency of collateral branches.


Assuntos
Angioplastia com Balão/instrumentação , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Angioplastia com Balão/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Circulação Colateral , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Remodelação Vascular
2.
J Vasc Surg ; 59(3): 645-50, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24246535

RESUMO

OBJECTIVE: This study evaluated the safety and effectiveness of the Zenith Dissection Endovascular System (Cook Medical, Bloomington, Ind) in the urgent treatment of acute type B aortic dissections complicated by organ malperfusion. METHODS: Between June 2011 and June 2013, we prospectively enrolled all patients with acute type B dissection (<14 days) complicated by visceral malperfusion and treated by the Zenith Dissection Endovascular System, including a proximal covered stent and a distal noncovered stent. Organ malperfusion was diagnosed during the clinical, biological, and morphologic follow-up of patients admitted to a dedicated intensive care unit (SOS Aorta). End points were 30-day mortality and morbidity, and reoperation rate, survival, and remodelling of the dissected aorta during follow-up. RESULTS: Fifteen patients (11 men; mean age, 60 ± 12 years) were treated in emergency procedures with a median delay of 36 hours. Malperfusions included renal ischemia in all patients, intestinal ischemia in nine, and lower limb ischemia in six. The proximal entry tear in each patient was covered by a stent Zenith TX2 graft (mean diameter, 36 mm; mean length, 170 mm; Cook Medical), supplemented by a noncovered aortic stent (diameter, 36 or 46 mm; length, 164 mm) with a technical success rate of 100%. The left subclavian artery in 10 patients was covered without revascularization. One chimney was necessary to revascularize the left common carotid artery. Six patients required complementary arterial branch stenting for persistent static malperfusion, using eight peripheral stents (five iliacs, three renals). No deaths were recorded during the 30-day postoperative period. Major adverse events were reported in three patients (20%): 1 paraparesis with complete recovery, 1 colonic resection, 1 stroke, and 2 transient renal failures. The mean hospital stay was 14 ± 6 days. During a mean follow-up of 8 ± 3 months, one sudden death, no aortic-related complications, and no reoperations or conversions were recorded. Remodelling with healing of the thoracic false lumen was obtained in 10 patients (67%), and five others had a partially thrombosed false lumen without remodelling. CONCLUSIONS: Used as a treatment for organ malperfusion complicating acute type B dissections, the Zenith Dissection Endovascular System achieved safely and effectively satisfactory clinical results in the short term. The long-term effect of this composite treatment on aortic remodelling remains to be determined.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Isquemia/cirurgia , Stents , Doença Aguda , Idoso , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Emergências , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Isquemia/diagnóstico , Isquemia/etiologia , Isquemia/mortalidade , Isquemia/fisiopatologia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fluxo Sanguíneo Regional , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
J Thorac Cardiovasc Surg ; 156(5): 1787-1793, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29934004

RESUMO

OBJECTIVE: The study objective was to assess the midterm outcomes and aortic remodeling in patients with Marfan syndrome with complicated acute type B aortic dissection treated with stent-assisted, balloon-induced intimal disruption and relamination. METHODS: We reviewed all patients treated with stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection associated with Marfan syndrome according to the revised Ghent criteria. RESULTS: Between 2015 and November 2017, 7 patients with Marfan syndrome underwent stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection. The median age of patients was 47 years (range, 23-70). Four patients had a history of aortic root replacement. Technical success was achieved in 100%. Three patients required an adjunctive procedure for renal artery stenting (n = 2) and iliac artery stenting (n = 1). There was no in-hospital death, 30-day postoperative stroke, spinal cord ischemia, ischemic colitis, or renal failure requiring dialysis. At a median follow-up of 15 months (range, 7-28), 1 patient required aortic arch replacement for aneurysmal degeneration associated with a type Ia endoleak at 2 years, giving a late reintervention rate of 14%. There was no other secondary endoleak. The primary visceral patency rate was 100%. There were no all-cause deaths reported. At last computed tomography scan, all patients had complete aortic remodeling of the treated thoracoabdominal aorta. Distally, at the nonstented infrarenal aortoiliac level, 6 patients had persistent false lumen flow with stable aorto-iliac diameter in 5. One patient had iliac diameter growth (27 mm diameter at last computed tomography scan). CONCLUSIONS: Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome is feasible, safe, and associated with an immediate and midterm persisting thoracoabdominal aortic remodeling.


Assuntos
Angioplastia com Balão/instrumentação , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Síndrome de Marfan/complicações , Stents , Remodelação Vascular , Adulto , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/fisiopatologia , Angioplastia com Balão/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/etiologia , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Feminino , Humanos , Masculino , Síndrome de Marfan/diagnóstico , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA