Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Electrophoresis ; 45(11-12): 1041-1053, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38477690

RESUMO

In this paper, the development and application of a multiple heart-cutting achiral-chiral LC-LC method (mLC-LC) for the analysis of dansylated (Dns) branched-chain amino acids in commercial tablets are described. In the first dimension, a Waters Xbridge RP C18 achiral column was used under gradient conditions with buffered aqueous solution and acetonitrile. The elution order Dns-valine (Dns-Val) < Dns-isoleucine (Dns-Ile) < Dns-leucine (Dns-Leu) turned out with full resolution between adjacent peaks: 7.25 and 1.50 for the Val/Ile and the Ile/Leu pairs, respectively. A "research" validation study was performed, revealing high accuracy (Recovery%) and precision (RSD%) using two external set solutions, respectively, in the range 93.7%-104.1% and 0.4%-3.2%. The C18 column was connected via a two-position six-port switching valve to the quinidine-based Chiralpak quinidine-anion-exchange chiral column. A water/acetonitrile, 30/70 (v/v) with 50 mM ammonium acetate (apparent pH of 5.5) eluent allowed getting the three enantiomers' pairs resolved: RS equal to 4.3 for Dns-Val and Dns-Ile, and 1.7 for Dns-Leu. The application of the mLC-LC method confirmed that the content of Val, Ile, and Leu in the tablets was compliant with that labeled by the producer. Only l-enantiomers were found in the food supplement, as confirmed by LC-MS/MS analysis.


Assuntos
Aminoácidos de Cadeia Ramificada , Comprimidos , Comprimidos/química , Aminoácidos de Cadeia Ramificada/análise , Aminoácidos de Cadeia Ramificada/química , Estereoisomerismo , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Compostos de Dansil/química , Espectrometria de Massas em Tandem/métodos , Modelos Lineares
2.
J Sep Sci ; 46(18): e2300346, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37438993

RESUMO

A fast HPLC method was developed to study the hydrophobicity extent of pharmaceutically relevant molecular fragments. By this strategy, the reduced amount of sample available for physico-chemical evaluations in early-phase drug discovery programs does not represent a limiting factor. The sixteen acid fragments investigated were previously synthesized also determining potentiometrically their experimental log D values. For four fragments it was not possible to determine such property since their values were outside of the instrumental working range (2 < pKa  < 12). An RP-HPLC method was therefore optimized. For each scrutinized method, some derived chromatographic indices were calculated, and Pearson's correlation coefficient (r) allowed to select the so-called "φ0 index" as the best correlating with the log D. The w s p H ${}_w/pH$ was fixed at 3.5 and a modification of some variables [organic modifier (methanol vs. ACN), stationary phase (octyl vs. octadecyl), presence/absence of the additives n-octanol, n-butylamine, and n-octylamine], allowed to select the best correlation conditions, producing a r = 0.94 (p < 0.001). Importantly, the φ0 index enabled the estimation of log D values for four fragments which were unattainable by potentiometric titration. Moreover, a series of molecular descriptors were calculated to identify the chemical characteristics of the fragments explaining the obtained φ0 . The number of hydrogen bond donors and the index of cohesive interaction correlated with the experimental data.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA