Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
J Nucl Cardiol ; 30(5): 2006-2017, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36598748

RESUMO

Dynamic acquisition allows absolute quantification of myocardial perfusion and flow reserve, offering an alternative to overcome the potential limits of relative quantification, especially in patients with balanced multivessel coronary artery disease. SPECT myocardial perfusion is widely available, at lower cost than PET. Dynamic cardiac SPECT is now feasible and has the potential to be the next step of comprehensive perfusion imaging. In order to help nuclear cardiologists potentially interested in using dynamic perfusion SPECT, we sought to review the different steps of acquisition, processing, and reporting of dynamic SPECT studies in order to enlighten the potentially critical pitfalls and artifacts. Both patient-related and technical artifacts are discussed. Key parameters of the acquisition include pharmacological stress, radiopharmaceuticals, and injection device. When it comes to image processing, attention must be paid to image-derived input function, patient motion, and extra-cardiac activity. This review also mentions compartment models, cameras, and attenuation correction. Finally, published data enlighten some facets of dynamic cardiac SPECT while several issues remain. Harmonizing acquisition and quality control procedures will likely improve its performance and clinical strength.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Artefatos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Compostos Radiofarmacêuticos , Perfusão , Imagem de Perfusão do Miocárdio/métodos
2.
J Nucl Cardiol ; 30(4): 1399-1405, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36352084

RESUMO

BACKGROUND: Residual activity in dispensing syringes is a problem that has been sporadically reported with various radiopharmaceuticals. Studies with [99mTc]Tc-tetrofosmin are non-consistent so far. The aim was to quantify the residual activity of [99mTc]Tc-tetrofosmin in different syringes in a clinical setting and to assess its impact on the clinical imaging procedure. METHODS: The residual activity of [99mTc]Tc-tetrofosmin was measured in 3 types of syringes: 3-part lubricated and non-lubricated syringes and 2-part syringe (n ≥ 30 for each syringe). The residual activity was located and quantified using a CzT SPECT camera and radio-counting then was correlated with different clinical parameters and processed by multiple linear regression analysis. RESULTS: Residual activity was different in all syringe types but lubricated syringes showed significantly higher levels with a mean ± SD of 26.12 ± 10.21% (P < .001). For these syringes, the residual activity was mainly located on the lubricated body. They also have a positive and significant impact on the standardized counting duration of patients' acquisitions. CONCLUSION: Lubricated syringes with high residual activity should be avoided as they increase the risk of prolonging patient acquisition time and potentially increasing the risk of poor image quality.


Assuntos
Imagem de Perfusão do Miocárdio , Seringas , Humanos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Compostos Organofosforados , Compostos de Organotecnécio
3.
J Nucl Cardiol ; 29(2): 506-514, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-32715418

RESUMO

BACKGROUND: The aim of this study was to investigate the feasibility of assessing absolute myocardial 99mTc-HMDP uptake in patients with suspected cardiac ATTR using SUV with a whole-body CZT SPECT-CT camera (DNM670CZT). METHODS: Fifteen patients with suspected cardiac ATTR (Perugini ≥ 2) underwent a conventional 99mTc-HMDP planar imaging and a thoracic SPECT/CT using a DNM 670CZT. A control group consisted of 15 patients with negative scintigraphy (Perugini < 2). SUVmax (mg·L-1) and percentage of injected dose (%ID) were calculated in a cardiac volume of interest (VOI) encompassing the left ventricle. VOIs were also placed in the lung, the right pectoris major, and the sternum. A heart-to-lung SUVmax ratio (HLR) was calculated. RESULTS: All ATTR patients demonstrated an increased cardiac HMDP SUVmax (12.2 ± 3.7 mg·L-1) vs controls (3.5 ± 1.2, P < .0001). Percentage of ID, pectoral uptake and HLR were significantly higher in the ATTR group (1.1 ± 0.3 vs 0.15 ± 0.8, P < .0001; 1.5 ± 0.3 vs 0.9 ± 0.3, P < .0001; 9.7 ± 3 vs 4.3 ± 2.2, P < .0001). Bone uptake was not statistically different between the two groups. CONCLUSION: This study demonstrated the feasibility of quantitative 99mTc-HMDP SUVmax measurement using a whole-body SPECT/CT CZT camera in patients with suspected cardiac ATTR.


Assuntos
Amiloidose , Pré-Albumina , Cádmio , Humanos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Telúrio , Zinco
4.
Eur J Nucl Med Mol Imaging ; 48(4): 1040-1069, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33135093

RESUMO

The use of cardiac PET, and in particular of quantitative myocardial perfusion PET, has been growing during the last years, because scanners are becoming widely available and because several studies have convincingly demonstrated the advantages of this imaging approach. Therefore, there is a need of determining the procedural modalities for performing high-quality studies and obtaining from this demanding technique the most in terms of both measurement reliability and clinical data. Although the field is rapidly evolving, with progresses in hardware and software, and the near perspective of new tracers, the EANM Cardiovascular Committee found it reasonable and useful to expose in an updated text the state of the art of quantitative myocardial perfusion PET, in order to establish an effective use of this modality and to help implementing it on a wider basis. Together with the many steps necessary for the correct execution of quantitative measurements, the importance of a multiparametric approach and of a comprehensive and clinically useful report have been stressed.


Assuntos
Sistema Cardiovascular , Imagem de Perfusão do Miocárdio , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Radioisótopos , Reprodutibilidade dos Testes
5.
Eur J Nucl Med Mol Imaging ; 48(13): 4331-4338, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34169368

RESUMO

PURPOSE: The coronavirus disease 2019 (COVID-19) pandemic reshaped the usual risk: benefit equilibrium that became a trade-off between the infection exposure risk for the patient (and for staff) and the risk associated with delaying or cancelling the nuclear medicine examination. This study aimed at quantifying the impact of the first COVID-19 lockdown in France on nuclear medicine examination volume together with volume of examination cancellation and non-attendance. METHODS: We retrospectively assessed the volume of planned examinations from 1 month before to 1 month after the first lockdown in French high-volume nuclear medicine departments (NMD) sharing the same information management system including both university hospitals, UH (n = 7), and cancer centres, CC (n = 2). RESULTS: The study enrolled 31,628 consecutive patients referred for a nuclear medicine examination performed or not (NMEP or NMEnP). The total volume of NMEP significantly dropped by 43.4% between the 4 weeks before and after the starting of the lockdown. The comparison of the percentage of NMEP and NMEnP between UH and CC is significantly different (p < 0.001). The percentage of NMEP during the study was 67.9% in UH vs 84.7% in CC. Percentages of NMEnP in UH and CC were due respectively to cancellation by the patient (14.9 vs 7.4%), cancellation by the NMD (9.5 vs 3.4%), cancellation by the referring physician (5.1 vs 4.4%) and non-attender patients (2.7 vs 0.2%). CONCLUSION: The study underlines the public health issue caused by COVID-19 above the pandemic itself and should be useful in preparing for potential resource utilisation and staffing requirements.


Assuntos
COVID-19 , Medicina Nuclear , Controle de Doenças Transmissíveis , França/epidemiologia , Humanos , Estudos Retrospectivos , SARS-CoV-2
6.
J Nucl Cardiol ; 28(4): 1477-1486, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31452085

RESUMO

BACKGROUND: We compared quantification of MBF and myocardial flow reserve (MFR) with a 99mTc-sestamibi CZT-SPECT to 15O-water PET. METHODS: SPECT MBF for thirty patients in the WATERDAY study was re-analyzed by QPET software with motion correction and optimal placement of the arterial input function. 15O-water PET MBF was re-quantified using dedicated software. Inter-operator variability was assessed using repeatability coefficients (RPC). RESULTS: Significant correlations were observed between global (r = 0.91, P < 0.001) and regional MBF (r = 0.86, P < 0.001) with SPECT compared to PET. Global MBF (rest 0.95 vs 1.05 ml/min/g, P = 0.07; stress 2.62 vs 2.68 mL/min/g, P = 0.17) and MFR (2.65 vs 2.75, P = 0.86) were similar between SPECT and PET. Rest (0.81 vs 0.98 mL/min/g, P = 0.03) and stress MBF (1.98 vs 2.61 mL/min/g, P = 0.01) in right coronary artery (RCA) were lower with SPECT compared to PET. However, MFR in the RCA territory was similar (2.54 vs 2.77, P = 0.21). The SPECT-PET RPC for global MBFs and MFR were 0.95 mL/min/g and 0.94, with inter-observer RPC of 0.59 mL/min/g and 0.74, respectively. CONCLUSIONS: MBF and MFR derived from CZT-SPECT with motion correction and optimal placement of the arterial input function showed good agreement with 15O-water PET, as well as low inter-operator variability.


Assuntos
Cádmio , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Idoso , Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Tecnécio Tc 99m Sestamibi , Água
7.
J Nucl Cardiol ; 28(4): 1490-1503, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31468379

RESUMO

BACKGROUND: To evaluate whether planar 123I-MIBG myocardial scintigraphy predicts risk of death in heart failure (HF) patients up to 5 years after imaging. METHODS AND RESULTS: Subjects from ADMIRE-HF were followed for approximately 5 years after imaging (964 subjects, median follow-up 62.7 months). Subjects were stratified according to the heart/mediastinum (H/M) ratio (< 1.60 vs ≥ 1.60) on planar 123I-MIBG scintigraphic images obtained at baseline in ADMIRE-HF. Cox proportional hazards models and Kaplan-Meier analyses were used to evaluate time to death, cardiac death, or arrhythmic events for subjects stratified by H/M ratio, baseline left ventricular ejection fraction (LVEF: < 25% and 25 to ≤ 35%), and by H/M strata within LVEF strata. All-cause mortality was 38.4% vs 20.9% and cardiac mortality was 16.8% vs 4.5%, in subjects with H/M < 1.60 vs ≥ 1.60, respectively (P < 0.05 for both comparisons). Subjects with preserved sympathetic innervation of the myocardium (H/M ≥ 1.60) were at significantly lower risk of all-cause and cardiac death, arrhythmic events, sudden cardiac death, or potentially life-threatening arrhythmias. Within LVEF strata, a trend toward a higher mortality for subjects with H/M < 1.60 was observed reaching significance for LVEF 25 to ≤ 35% only. CONCLUSIONS: During a median follow-up of 62.7 months, patients with H/M ≥ 1.60 were at significantly lower risk of death and arrhythmic events independently of LVEF values.


Assuntos
3-Iodobenzilguanidina , Insuficiência Cardíaca/diagnóstico por imagem , Coração/inervação , Radioisótopos do Iodo , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Volume Sistólico , Análise de Sobrevida , Sistema Nervoso Simpático/diagnóstico por imagem , Fatores de Tempo
8.
J Nucl Cardiol ; 28(3): 1105-1116, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33521873

RESUMO

BACKGROUND: Positron emission tomography (PET) myocardial perfusion imaging (MPI) with the novel radiopharmaceutical Fluorine-18 Flurpiridaz has been shown in Phase 1, 2, and first Phase 3 clinical studies to be safe and effective in diagnosing coronary artery disease (CAD). We describe the methodology of the second FDA-mandated phase 3 prospective, open-label, international, multi-center trial of F-18 Flurpiridaz PET MPI. METHODS: The primary study end point is to assess the diagnostic efficacy of F-18 Flurpiridaz PET MPI in the detection of significant CAD [≥ 50% by quantitative invasive coronary angiography (ICA)] in patients with suspected CAD. The secondary endpoints are to evaluate the diagnostic efficacy of F-18 Flurpiridaz PET MPI compared to Tc-99 m-labeled SPECT MPI in the detection of CAD in all patients and in the following subgroups: (1) females; (2) patients with body mass index ≥ 30 kg/m2; and (3) diabetic patients. This trial's design differs from the first phase 3 trial in that (1) comparison to SPECT is now a secondary end point; (2) patients with known CAD are excluded; and (3) both SPECT and PET MPI are performed before ICA. CONCLUSIONS: This second phase 3 study will provide additional evidence on the diagnostic efficacy of F-18 Flurpiridaz PET MPI in the detection of significant CAD. TRIAL REGISTRATION NUMBER: NCT03354273.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Piridazinas , Ensaios Clínicos Fase III como Assunto , Humanos , Estudos Multicêntricos como Assunto , Projetos de Pesquisa
9.
J Nucl Cardiol ; 27(6): 2247-2257, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-30515748

RESUMO

BACKGROUND: This study aimed to determine whether the repeatability of dyssynchrony assessment using gated myocardial perfusion SPECT (GSPECT) allows the detection of synchrony reserve during low-dose dobutamine infusion. METHODS AND RESULTS: Sixty-one patients with ischemic cardiomyopathy and LV ejection fraction < 50% were prospectively included in 10 centers. Each patient underwent two consecutive rest GSPECT with 99mTc-labeled tracer (either tetrofosmin or sestamibi) to assess the repeatability of LV function and dyssynchrony parameters, followed by a GSECT acquisition during low-dose dobutamine infusion. LV dyssynchrony was assessed using QGS software through histogram bandwidth (BW), standard deviation of the phase (SD), and entropy. Repeatability was assessed with Lin's concordance correlation coefficient (CCC). Entropy showed a higher CCC (0.80) compared to BW (0.68) and SD (0.75). On average, dobutamine infusion yielded to improve both BW (P = .049) and entropy (P = .04) although significant improvements, setting outside the 95% confidence interval of the repeatability analysis, were documented in only 6 and 4 patients for BW and entropy, respectively. CONCLUSIONS: A synchrony reserve may be documented in patients with ischemic cardiomyopathy through the recording of BW and entropy with low-dose dobutamine GSPECT, with the additional advantage of a higher repeatability for entropy.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Dobutamina/administração & dosagem , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tecnécio/química , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Entropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
10.
Eur J Nucl Med Mol Imaging ; 45(7): 1079-1090, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29497801

RESUMO

PURPOSE: We assessed the feasibility of myocardial blood flow (MBF) and flow reserve (MFR) estimation using dynamic SPECT with a novel CZT camera in patients with stable CAD, in comparison with 15O-water PET and fractional flow reserve (FFR). METHODS: Thirty patients were prospectively included and underwent FFR measurements in the main coronary arteries (LAD, LCx, RCA). A stenosis ≥50% was considered obstructive and a FFR abnormal if ≤0.8. All patients underwent a dynamic rest/stress 99mTc-sestamibi CZT-SPECT and 15O-water PET for MBF and MFR calculation. Net retention kinetic modeling was applied to SPECT data to estimate global uptake values, and MBF was derived using Leppo correction. Ischemia by PET and CZT-SPECT was considered present if MFR was lower than 2 and 2.1, respectively. RESULTS: CZT-SPECT yielded higher stress and rest MBF compared to PET for global and LAD and LCx territories, but not in RCA territory. MFR was similar in global and each vessel territory for both modalities. The sensitivity, specificity, accuracy, positive and negative predictive value of CZT-SPECT were, respectively, 83.3, 95.8, 93.3, 100 and 85.7% for the detection of ischemia and 58.3, 84.6, 81.1, 36.8 and 93% for the detection of hemodynamically significant stenosis (FFR ≤ 0.8). CONCLUSIONS: Dynamic 99mTc-sestamibi CZT-SPECT was technically feasible and provided similar MFR compared to 15O-water PET and high diagnostic value for detecting impaired MFR and abnormal FFR in patients with stable CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Água
11.
J Nucl Cardiol ; 25(5): 1692-1704, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-28275896

RESUMO

BACKGROUND: We studied the impact of simultaneous dual-isotope acquisition on 123I/99mTc mismatch assessment using two CZT cameras (DNM 530c, GE Healthcare and DSPECT, Biosensors International). METHODS: We used an anthropomorphic torso phantom (respectively filled with a solution of 123I alone, 99mTc alone, and a mixture of 123I and 99mTc) and its cardiac insert with two defects mimicking two matched and mismatched defects. Mismatch extent and reconstructed image contrast were evaluated. RESULTS: The acquisition mode (single vs dual) significantly impacted (i) 99mTc (but not 123I) reconstructed segmental activities using both camera (P < .001), and (ii) image contrast (using 123I and DNM 530c, P < .0001; and using both 123I and 99mTc with DSPECT, P < .0001). However, the defect and mismatch size were not impacted by the type of acquisition. With both DNM 530c and DSPECT, Lin's concordance correlation coefficient and Bland-Altman analysis demonstrated an almost perfect concordance and agreement between single- and simultaneous dual-isotope segmental activity (123I and 99mTc). CONCLUSIONS: This study found no impact of the acquisition mode (single vs dual) or the type of camera (DSPECT vs DNM 530c) on 123I and 99mTc defect size and mismatch, providing a new step toward simultaneous dual-isotope acquisition for combined innervation and perfusion assessment.


Assuntos
Coração/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cádmio , Humanos , Radioisótopos do Iodo , Traçadores Radioativos , Tecnécio , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Zinco
12.
Eur J Nucl Med Mol Imaging ; 43(2): 288-295, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26280980

RESUMO

PURPOSE: Myocardial blood flow (MBF) measurement using positron emission tomography (PET) from the washout rate of (15)O-water is theoretically independent of tissue attenuation. The aim of this study was to evaluate the impact of not using attenuation correction in the assessment of coronary endothelial function and myocardial flow reserve (MFR) using (15)O-water PET. METHODS: We retrospectively processed 70 consecutive (15)O-water PET examinations obtained at rest and during cold pressor testing (CPT) in patients with dilated cardiomyopathy (n = 58), or at rest and during adenosine infusion in heart transplant recipients (n = 12). Data were reconstructed with attenuation correction (AC) and without attenuation correction (NAC) using filtered backprojection, and MBF was quantified using a single compartmental model. The agreement between AC and NAC data was assessed using Lin's concordance correlation coefficient followed by Bland-Altman plot analysis. RESULTS: Regarding endothelial function, NAC PET showed poor reproducibility and poor agreement with AC PET data. Conversely, NAC PET demonstrated high reproducibility and a strong agreement with AC PET for the assessment of MFR. CONCLUSION: Non-attenuation-corrected (15)O-water PET provided an accurate measurement of MFR compared to attenuation-corrected PET. However, non-attenuation-corrected PET data were less effective for the assessment of endothelial function using CPT in this population.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Endotélio Vascular/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Endotélio Vascular/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
13.
Eur J Nucl Med Mol Imaging ; 43(8): 1530-45, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26846913

RESUMO

Until recently, PET was regarded as a luxurious way of performing myocardial perfusion scintigraphy, with excellent image quality and diagnostic capabilities that hardly justified the additional cost and procedural effort. Quantitative perfusion PET was considered a major improvement over standard qualitative imaging, because it allows the measurement of parameters not otherwise available, but for many years its use was confined to academic and research settings. In recent years, however, several factors have contributed to the renewal of interest in quantitative perfusion PET, which has become a much more readily accessible technique due to progress in hardware and the availability of dedicated and user-friendly platforms and programs. In spite of this evolution and of the growing evidence that quantitative perfusion PET can play a role in the clinical setting, there are not yet clear indications for its clinical use. Therefore, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, decided to examine the current literature on quantitative perfusion PET to (1) evaluate the rationale for its clinical use, (2) identify the main methodological requirements, (3) identify the remaining technical difficulties, (4) define the most reliable interpretation criteria, and finally (5) tentatively delineate currently acceptable and possibly appropriate clinical indications. The present position paper must be considered as a starting point aiming to promote a wider use of quantitative perfusion PET and to encourage the conception and execution of the studies needed to definitely establish its role in clinical practice.


Assuntos
Medicina Nuclear , Tomografia por Emissão de Pósitrons/métodos , Sociedades Médicas , Sistema Cardiovascular/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Compostos Radiofarmacêuticos
14.
Eur J Nucl Med Mol Imaging ; 43(4): 780-92, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26678270

RESUMO

Cardiovascular diseases are the leading cause of death not only in Europe but also in the rest of the World. Preventive measures, however, often fail and cardiovascular disease may manifest as an acute coronary syndrome, stroke or even sudden death after years of silent progression. Thus, there is a considerable need for innovative diagnostic and therapeutic approaches to improve the quality of care and limit the burden of cardiovascular diseases. During the past 10 years, several retrospective and prospective clinical studies have been published using (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) to quantify inflammation in atherosclerotic plaques. However, the current variety of imaging protocols used for vascular (arterial) imaging with FDG PET considerably limits the ability to compare results between studies and to build large multicentre imaging registries. Based on the existing literature and the experience of the Members of the European Association of Nuclear Medicine (EANM) Cardiovascular Committee, the objective of this position paper was to propose optimized and standardized protocols for imaging and interpretation of PET scans in atherosclerosis. These recommendations do not, however, replace the individual responsibility of healthcare professionals to make appropriate decisions in the circumstances of the individual study protocols used and the individual patient, in consultation with the patient and, where appropriate and necessary, the patient's guardian or carer. These recommendations suffer from the absence of conclusive evidence on many of the recommendations. Therefore, they are not intended and should not be used as "strict guidelines" but should, as already mentioned, provide a basis for standardized clinical atherosclerosis PET imaging protocols, which are subject to further and continuing evaluation and improvement. However, this EANM position paper might indeed be a first step towards "official" guidelines on atherosclerosis imaging with PET.


Assuntos
Aterosclerose/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Humanos , Tomografia por Emissão de Pósitrons/efeitos adversos , Tomografia por Emissão de Pósitrons/normas , Compostos Radiofarmacêuticos
15.
Eur J Nucl Med Mol Imaging ; 43(13): 2423-2432, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27542010

RESUMO

The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.


Assuntos
Técnicas de Imagem Cardíaca/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Cintilografia/métodos , Compostos de Cádmio/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Europa (Continente) , Medicina Baseada em Evidências , Raios gama , Humanos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Telúrio/efeitos da radiação , Zinco/efeitos da radiação
17.
Eur J Nucl Med Mol Imaging ; 42(7): 1043-51, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25626701

RESUMO

PURPOSE: The aim of this study was to determine the potential diagnostic value of regional myocardial adrenergic (123)I-metaiodobenzylguanidine (MIBG) single photon emission computed tomography (SPECT) imaging to identify patients with Lewy body diseases (LBD+). METHODS: Sixty-four consecutive patients who underwent cardiac (123)I-MIBG SPECT to differentiate LBD+, including Parkinson's disease (PD) and dementia with Lewy bodies (DLB), from patients without LBD (LBD-) were retrospectively reviewed. A neurologist expert in memory disorders determined the final clinical diagnosis by using international clinical diagnostic criteria. Planar [heart to mediastinum ratio (HMR)] and (123)I-MIBG SPECT[(innervation defect score (IDS)] using the 17-segment left ventricular model (five-point scale) were obtained 4 h after the injection of (123)I-MIBG on a low-energy high-resolution (LEHR) collimator. Receiver-operating characteristic (ROC) analysis was performed to determine the optimal HMR and IDS cut-off values to discriminate LBD+ from LBD-. RESULTS: Of the 64 patients, 45 (70 %) were diagnosed LBD+ (DLB, n = 27; PD, n = 18) and 19 were diagnosed LBD- (5 other dementias, 14 other parkinsonisms). The HMR and IDS of LBD+ were significantly different from those of LBD- (1.30 ± 0.21 vs 1.65 ± 0.26, p < 0.001; 39 ± 28 vs 8 ± 16, p = 0.001). The optimal HMR and IDS cut-off values to discriminate LBD+ (n = 45) from LBD- (n = 19) were 1.47 and 6/68, providing a sensitivity and specificity of 82.2 and 84.2% and 86.7 and 73.7%, respectively. CONCLUSION: Regional myocardial adrenergic (123)I-MIBG imaging SPECT has a potential diagnostic value to identify LBD+.


Assuntos
3-Iodobenzilguanidina , Doença por Corpos de Lewy/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Doença por Corpos de Lewy/patologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
18.
Eur J Nucl Med Mol Imaging ; 42(12): 1912-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26227533

RESUMO

PURPOSE: Cardiac innervation is assessed using the heart-to-mediastinum ratio (HMR) of metaiodobenzylguanidine (MIBG) on planar imaging using Anger single photon emission computed tomography (A-SPECT). The aim of the study was to determine the HMR of MIBG obtained using a CZT-based camera (D-SPECT; Spectrum Dynamics, Israel) in comparison with that obtained using conventional planar imaging. METHODS: The ADRECARD study prospectively evaluated 44 patients with heart failure. They underwent planar acquisition using the A-SPECT camera 4 h after (123)I-MIBG injection (236.4 ± 39.7 MBq). To localize the heart using D-SPECT, (99m)Tc-tetrofosmin (753 ± 133 MBq) was administered and dual isotope acquisition was performed using the D-SPECT system. HMR was calculated using both planar A-SPECT imaging and front view D-SPECT cine data. In a phantom study, we estimated a model fitting the A-SPECT and the D-SPECT data that was further applied to correct for differences between the cameras. RESULTS: A total of 44 patients (39 men and 5 women, aged 60 ± 11 years) with ischaemic (31 patients) and nonischaemic (13 patients) cardiomyopathy completed the study. Most patients (28 of 44) were NYHA class II, and the mean left ventricular ejection fraction was 33 ± 7 %. The mean HMR values were 1.34 ± 0.15 and 1.45 ± 0.27 from A-SPECT and D-SPECT, respectively (p < 0.0001). After correction, Lin's concordance correlation showed an almost perfect concordance between corrected D-SPECT HMR and A-SPECT HMR, and Bland-Altman analysis demonstrated a high agreement between the two measurements. CONCLUSION: The ADRECARD study demonstrated that determination of late HMR during cardiac MIBG imaging using dual isotope ((123)I and (99m)Tc) acquisition on a CZT camera (D-SPECT) is feasible in patients with heart failure. A linear correction based on the phantom study yielded a high agreement between (123)I MIBG HMR obtained using a CZT camera and that from conventional planar imaging.


Assuntos
3-Iodobenzilguanidina , Câmaras gama , Insuficiência Cardíaca/diagnóstico por imagem , Coração/diagnóstico por imagem , Mediastino/diagnóstico por imagem , Compostos Organofosforados , Compostos de Organotecnécio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
19.
BMC Neurol ; 15: 83, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25971430

RESUMO

BACKGROUND: Different studies have found diminished cardiac metaiodobenzylguanidine (MIBG) uptake in Lewy body (LB) related conditions (Parkinson's disease (PD) and Lewy body dementia (LBD)). However, delayed heart/mediastinum (d-H/M) ratio diagnostic cutoff points are debated in parkinsonian syndromes. METHODS: We performed a monocentric retrospective analysis on 62 consecutive parkinsonian patients who underwent an (123)I-MIBG scintigraphy, brain imaging and dopaminergic imaging using (123)I-Ioflupane single photon emission computed tomography (SPECT) from 2009 to 2013. The optimal d-H/M ratio was determined from a Receiver Operating Characteristic (ROC) curve and the sensitivity (Se), specificity (Sp) and likelihood ratios (LR) were calculated. 42 patients were diagnosed with LB diseases (20 PD, 22 LBD) and 20 patients with other diseases. RESULTS: (123)I-MIBG scintigraphy helped to distinguish PD (p < 0.001) and LBD (p = 0.03) from other diseases. The optimal d-H/M ratio was 1.48 (0.85 area under the ROC curve). Se and Sp were 83.3 %, and 85 % respectively with positive and negative LR of 5.5 and 0.2 respectively. Patients with LBD had a lower d-H/M ratio than patients with PD (result not statistically significant) and a cutoff point at 1.2 could help to differentiate the two diseases. We did not find any correlation between the d-H/M ratio and clinical or (123)I-Ioflupane SPECT data. CONCLUSION: According to our population, the d-H/M ratio at 1.48 led to the best performance diagnosis with good Se, Sp and accuracy. In addition, a d-H/M ratio cutoff at 1.2 could help to differentiate PD from LBD.


Assuntos
Coração/diagnóstico por imagem , Doença por Corpos de Lewy/diagnóstico por imagem , Mediastino/diagnóstico por imagem , Doença de Parkinson/diagnóstico por imagem , Transtornos Parkinsonianos/diagnóstico por imagem , 3-Iodobenzilguanidina/química , Idoso , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Compostos Radiofarmacêuticos/química , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único
20.
Eur J Nucl Med Mol Imaging ; 41(1): 155-66, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24008434

RESUMO

PURPOSE: Giant cell arteritis (GCA) is the most common form of vasculitis in western countries. (18)F-FDG PET has been shown to be a valuable tool for the diagnosis of extracranial GCA, but results of studies are inconsistent due to a lack of standardized (18)F-FDG PET criteria. In this study, we compared different semiquantitative approaches using a controlled design to define the most efficient method. METHODS: All patients with biopsy-proven GCA who had undergone an (18)F-FDG PET/CT scan in our PET unit were reviewed and matched with a control group based on age and sex. Different semiquantitative arterial (ascending and descending thoracic aorta and aortic arch) to background (liver, lung and venous blood pool) SUV ratios were blindly compared between GCA patients and matched controls. RESULTS: We included 11 patients with biopsy-proven GCA cases and 11 matched controls. There were no differences between the groups with regard to body weight, injected radioactivity, blood glucose level or CRP. The arterial to venous blood pool ratios discriminated the two groups better than other methods when applied to the aortic arch and the descending thoracic aorta (p<0.015). In particular, the highest aortic to highest blood pool SUVmax ratio, when applied to the aortic arch, provided optimal diagnostic performance (sensitivity 81.8 %, specificity 91 %, AUC 0.87; p<0.0001) using a cut-off value of 1.53. CONCLUSION: Among all tested (18)F-FDG PET/CT methods, the aortic to blood pool SUVmax ratio outperformed the liver and lung ratios. We suggest the use of this ratio for the assessment of aortic inflammation in GCA patients.


Assuntos
Fluordesoxiglucose F18 , Arterite de Células Gigantes/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Casos e Controles , Arterite de Células Gigantes/patologia , Humanos , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA