Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Catheter Cardiovasc Interv ; 99(7): 2125-2130, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35420254

RESUMO

INTRODUCTION: The preferred approach for transcatheter aortic valve replacement (TAVR) is transfemoral. There has been widespread adoption of the Perclose ProglideTM device for vascular closure. Typically, two devices are deployed before upsizing the access sheath in the "preclose technique." Prior investigations have compared the use of a single device versus double device technique, but none have shown significant clinical benefit to either approach. METHODS: Five hundred and six patients underwent transfemoral TAVR (TF-TAVR) with single or double Perclose devices for vascular closure from July 2015 to February 2020. A retrospective review was conducted, and propensity-matched analyses were used to account for differences in baseline characteristics. RESULTS: In the matched analysis, there were 251 patients in the single Perclose group and 238 in the double. There was a statistically significant improvement in overall procedural success using the single closure device (94.6% vs. 88.5%, p = 0.009) This was defined as intraprocedural hemostatic control, lack of contrast extravasation, arterial dissection, occlusion, or stenosis >50% in the final crossover angiogram, as well as unimpaired limb perfusion without claudication throughout the index hospitalization. There was also a significant improvement in arterial dissection rates (0.6% vs. 4.6%, p = 0.004), stenosis >50% (1.3% vs. 4.4%, p = 0.028), and Valve Academic Research Consortium major vascular complications (1.8% vs. 4.9%, p = 0.038). CONCLUSION: A single Perclose device is a safe means of vascular closure during TF-TAVR and may have important clinical benefits compared to the commonly used two-device technique.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Constrição Patológica/complicações , Constrição Patológica/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Técnicas Hemostáticas/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 97(7): E956-E966, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33241630

RESUMO

Extrinsic compression of the left main coronary artery (LMCA) by a dilated pulmonary artery (PA) in the setting of pulmonary arterial hypertension (PAH) is an increasingly recognized disease entity. LMCA compression has been associated with angina, arrhythmia, heart failure, and sudden cardiac death in patients with PAH. Recent studies suggest that at least 6% of patients with PAH have significant LMCA compression. Screening for LMCA compression can be achieved with computed coronary tomography angiography, with a particular emphasis on assessment of PA size and any associated downward displacement and reduced takeoff angle of the LMCA. Indeed, evidence of a dilated PA (>40 mm), a reduced LMCA takeoff angle (<60°), and/or LMCA stenosis on CCTA imaging should prompt further diagnostic evaluation. Coronary angiography in conjunction with intravascular imaging has proven effective in diagnosing LMCA compression and guiding subsequent treatment. While optimal medical therapy and surgical correction remain in the clinician's arsenal, percutaneous coronary intervention has emerged as an effective treatment for LMCA compression. Given the prevalence of LMCA compression, its associated morbidity, and mortality, and the wide array of successful treatment strategies, maintaining a high degree of suspicion for this condition, and understanding the potential treatment strategies is critical.


Assuntos
Angioplastia Coronária com Balão , Estenose Coronária , Hipertensão Pulmonar , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Artéria Pulmonar/diagnóstico por imagem , Stents , Resultado do Tratamento
3.
Curr Cardiol Rep ; 22(12): 166, 2020 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-33037927

RESUMO

PURPOSE OF REVIEW: With increasing use of prosthetic valves to treat degenerative valvular heart disease (VHD) in an aging population, the incidence and adverse consequences of paravalvular leaks (PVL) are better recognized. The present work aims to provide a cohesive review of the available literature in order to better guide the evaluation and management of PVL. RECENT FINDINGS: Despite gains in operator experience and design innovation, significant PVL remains a significant complication that may present with congestive heart failure and/or hemolytic anemia. To date, clear consensus or guidelines on the evaluation and management of PVL remain lacking. Although the evolution of transcatheter valve therapies has had a tremendous impact on the management of patients with VHD, the limitations and complications of such techniques, including PVL, present further challenges. Incidence of PVL, graded as moderate or greater, ranges from 4 to 7.4% in surgical and transcatheter valve replacements, respectively. Improved imaging modalities and the advent of novel surgical and percutaneous therapies have undoubtedly yielded a better understanding of PVL including its anatomical location, mechanism, severity, and treatment options. Echocardiography, used in conjunction with cardiac computed tomography and cardiac magnetic resonance, provides essential details for diagnosis and management of PVL. Transcatheter intervention has become a favored approach in lieu of surgical intervention in select patients after previous surgical or percutaneous valve replacement. PVL treatment with vascular plugs, balloon post-dilation, and the valve-in-valve methods have shown technical success with promising clinical outcomes in appropriately selected patients.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Falha de Prótese , Resultado do Tratamento
4.
J Card Fail ; 25(3): 166-172, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30412734

RESUMO

BACKGROUND: Adverse cardiovascular events after liver transplantation (LT) are relatively common and are a significant source of early mortality. Although new-onset systolic dysfunction after LT is a reported phenomenon, there is little data regarding its incidence, risk factors, and outcomes. METHODS AND RESULTS: This single-center retrospective study included all adult patients from January 2002 to March 2015 with deceased-donor LT and available preoperative transthoracic echocardiograms (TTEs). In total, 1,760 patients were included in the study, 602 (34.2%) of whom had a postoperative TTE. The primary end point was development of new-onset cardiomyopathy, defined as a new left ventricular ejection fraction (LVEF) of <40% within 180days of transplant. Sixty-nine (11.4%) of the patients who received post-LT TTE had a reduction in LVEF to <40% within 6 months. Clinical parameters of donor and recipient did not show significant impact on development of post-LT LV systolic dysfunction (LVSD). Presence of wall motion abnormalities (P = .004) on preoperative TTE was predictive of development of post-LT LVSD. These patients did not have longer hospitalizations, but they had worse survival. CONCLUSIONS: Post-LT LV systolic dysfunction occurs at higher rates than previously suspected and may develop more frequently in patients with underlying cardiac structural abnormalities, which appear to adversely affect post-LT survival.


Assuntos
Transplante de Fígado/efeitos adversos , Transplante de Fígado/tendências , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/epidemiologia , Adulto , Estudos de Coortes , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
5.
Radiology ; 286(1): 326-337, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29040038

RESUMO

Purpose To assess the technical feasibility of the use of ferumoxytol-enhanced (FE) magnetic resonance (MR) angiography for vascular mapping before transcatheter aortic valve replacement in patients with renal impairment. Materials and Methods This was an institutional review board-approved and HIPAA-compliant study. FE MR angiography was performed at 3.0 T or 1.5 T. Unenhanced computed tomographic (CT) images were used to overlay vascular calcification on FE MR angiographic images as composite fused three-dimensional data. Image quality of the subclavian and aortoiliofemoral arterial tree and confidence in the assessment of calcification were evaluated by using a four-point scale (4 = excellent vascular definition or strong confidence). Signal intensity nonuniformity as reflected by the heterogeneity index (ratio between the mean standard deviation of luminal signal intensity and the mean luminal signal intensity), signal-to-noise ratio, and consistency of luminal diameter measurements were quantified. Findings at FE MR angiography were compared with pelvic angiograms. Results Twenty-six patients underwent FE MR angiography without adverse events. A total of 286 named vascular segments were scored. The image quality score was 4 for 99% (283 of 286) of the segments (κ = 0.9). There was moderate to strong confidence in the ability to assess vascular calcific morphology in all studies with complementary unenhanced CT. The steady-state luminal heterogeneity index was low, and signal-to-noise ratio was high. Interobserver luminal measurements were reliable (intraclass correlation coefficient, 0.98; 95% confidence interval: 0.98, 0.99). FE MR angiographic findings were consistent with correlative pelvic angiograms in all 16 patients for whom the latter were available. Conclusion In patients with renal impairment undergoing transcatheter aortic valve replacement, FE MR angiography is technically feasible and offers reliable vascular mapping without exposure to iodine- or gadolinium-based contrast agents. Thus, the total cumulative dose of iodine-based contrast material is minimized and the risk of acute nephropathy is reduced. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Óxido Ferroso-Férrico/uso terapêutico , Nefropatias/complicações , Angiografia por Ressonância Magnética/métodos , Medicina de Precisão/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
6.
J Surg Res ; 221: 304-310, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29229143

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has greatly expanded the treatment options available for patients with severe aortic stenosis at high surgical risk. MATERIALS AND METHODS: We compared changes in myocardial function in TAVR with a transfemoral (TF) versus a transapical (TA) approach at a major tertiary hospital from 2012-2016. Traditional echocardiographic measures of cardiac structure and function were tracked, alongside the use of two-dimensional speckle tracking echocardiography to measure myocardial strain and strain rates. RESULTS: For the entire cohort with complete data at all time points (n = 42), between the pre-TAVR baseline (mean: 20.1 d) and the post-TAVR 1-mo follow-up (mean: 32.7 d), global longitudinal strain significantly increased (from -15.6% to -18.2%, P < 0.001). When comparing the TF (n = 31) and TA (n = 11) groups, TA patients showed persistently impaired apical longitudinal strain at the 1-mo follow-up (-15.9% versus -22.3%, P < 0.05). In terms of clinical outcomes, both groups (n = 131 for TF, n = 53 for TA) were similar in terms of 30-d mortality, readmission rate, and risk of post-TAVR acute kidney injury. However, TA patients experienced significantly longer length of hospitalization (7.58 versus 3.92 d, P = 0.02), intensive care unit hours (105.4 versus 47.1 h, P = 0.02), and were at a greater risk of long-term (>72 h) intensive care unit stay (45% versus 25%, P = 0.01). CONCLUSIONS: Patients undergoing TA-TAVR exhibit impaired apical longitudinal strain, although global myocardial function is similar to TF-TAVR otherwise. Myocardial strain measured by two-dimensional speckle tracking echocardiography appears to be a sensitive method to detect subtle cardiac remodeling after TAVR.


Assuntos
Coração/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 85(3): 490-6, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25367712

RESUMO

BACKGROUND: The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. METHODS: All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine-angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) - (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group. RESULTS: Among the 23 mm valves, the mean (standard deviation-SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (P = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (P = 0.01). Multivariable linear regression analysis demonstrated significantly greater adjusted recoil in the SAPIEN XT valves as compared to the SAPIEN valves by 1.43% [(95% CI: 0.69-2.17), P < 0.001]. However, the residual peak gradient was less for SAPIEN XT compared to SAPIEN valves [18.86 mm Hg versus 23.53 mm Hg (P = 0.01)]. Additionally, no difference in paravalvular leak was noted between the two valve types (P = 0.78). CONCLUSIONS: The SAPIEN XT valves had significantly greater acute recoil after deployment compared to the SAPIEN valves. Implications of this difference in acute recoil on valve performance need to be investigated in future studies.


Assuntos
Valva Aórtica , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Artéria Femoral , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Ligas de Cromo , Cineangiografia , Elasticidade , Feminino , Humanos , Modelos Lineares , Masculino , Análise Multivariada , Ohio , Desenho de Prótese , Punções , Sistema de Registros , Aço Inoxidável , Resultado do Tratamento
8.
Med Sci Monit ; 21: 2116-24, 2015 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-26198682

RESUMO

BACKGROUND: Although myocardial bridging (MB) is defined as an angiographic phenomenon with a benign course, it has also been associated with adverse cardiovascular events. The effects of exercise on myocardial repolarization in patients with MB were tested in this study, with Tp-e and Tp-e/QT repolarization indexes. MATERIAL AND METHODS: A total of 50 patients in whom isolated MB was diagnosed at coronary angiography (CAG) (Group I) and 48 patients with normal CAG results (Group II) were included in this study. The participants underwent treadmill exercise stress testing according to the Bruce protocol. QT dispersion (QTd) was defined as the minimum QT interval subtracted from the maximum. The Tp-e interval was defined as the difference between the QT and the QT peak time period. QTd and Tp-e intervals were calculated for all patients before and after exercise testing and differences between groups were compared. RESULTS: At peak exercise, QTd and cQTd showed a significant increase in comparison to baseline values in the group of patients with myocardial bridges. Significant increases were also found with exercise in the Tp-e, cTp-e durations and Tp-e/QT ratio of the MB patient group in comparison to the baseline values. On the other hand, significant differences in QTd, cQTd, Tp-e, cTp-e intervals, and Tp-e/QT ratio during peak exercise in comparison with baseline values were not detected in the control group (p>0.05). CONCLUSIONS: Significant increases in QTd, cQTd, Tp-e and cTp-e intervals and Tp-e/QT ratio were detected in the MB patients during exercise testing.


Assuntos
Exercício Físico/fisiologia , Ponte Miocárdica/patologia , Ponte Miocárdica/fisiopatologia , Idoso , Estudos de Casos e Controles , Angiografia Coronária , Eletrocardiografia , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Estudos Prospectivos
9.
Ann Intern Med ; 161(10): 699-710, 2014 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-25402513

RESUMO

BACKGROUND: Data are lacking on the effect of renin-angiotensin system (RAS) blockade therapy with angiotensin-converting enzyme inhibitors or angiotensin-receptor blockers after surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS). OBJECTIVE: To investigate the association between RAS blockade therapy and outcomes after SAVR for severe AS. DESIGN: Retrospective study. SETTING: Single tertiary referral care center. PATIENTS: Patients who were prescribed angiotensin-converting enzyme inhibitors or angiotensin-receptor blockers after SAVR for severe AS between 1991 and 2010 who had at least 2 refills 90 days apart and at least a 6-month follow-up constituted the RAS blockade group (n = 741). Patients who did not receive these prescriptions were in the untreated group (n = 1011). Unadjusted and propensity-matched analyses (594 matched pairs of treated and untreated patients) were performed. MEASUREMENTS: The primary outcome was survival rates after SAVR. Secondary end points were changes in left ventricular mass index, left ventricular ejection fraction, and left atrial size. RESULTS: Overall unadjusted estimated survival rates at 1, 5, and 10 years were significantly greater in the RAS blockade group than in the non-RAS blockade group (99%, 90%, and 60% vs. 99%, 81%, and 53%, respectively; P < 0.001). Among propensity-matched patients, estimated survival rates at 1, 5, and 10 years remained significantly greater in the RAS blockade group than in the non-RAS blockade group (99%, 90%, and 71% vs. 96%, 78%, and 49%, respectively; P < 0.001). For the matched cohorts, the groups did not significantly differ in the change in left ventricular mass index (P = 0.37), left ventricular ejection fraction (P = 0.67), or left atrial size (P = 0.43) after SAVR on echocardiographic analysis. LIMITATION: Retrospective, single-center analysis. CONCLUSION: Renin-angiotensin system blockade therapy is associated with increased survival rates in patients after SAVR for severe AS. A randomized trial of RAS blockade therapy after SAVR should be considered. PRIMARY FUNDING SOURCE: None.


Assuntos
Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Sistema Renina-Angiotensina/efeitos dos fármacos , Idoso , Antagonistas de Receptores de Angiotensina/farmacologia , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Feminino , Seguimentos , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Retrospectivos , Taxa de Sobrevida , Ultrassonografia
10.
Artigo em Inglês | MEDLINE | ID: mdl-38904608

RESUMO

BACKGROUND: The optimal timing of noncardiac surgery (NCS) following transcatheter aortic valve replacement (TAVR) for aortic stenosis has not been elucidated by current national guidelines. OBJECTIVES: The aim of this study was to evaluate the effect of the time interval between TAVR and NCS (Δt) on the perioperative risk of major adverse events (MAEs). METHODS: All adult admissions for isolated TAVR for aortic stenosis were identified in the 2016 to 2020 Nationwide Readmissions Database. Patients who received NCS on subsequent admission were included for analysis and grouped by Δt as follows: ≤30, 31 to 60, 61 to 90, and >90 days. Multivariable regression models were constructed to examine the association of Δt with ensuing outcomes. RESULTS: Of 3,098 patients (median age = 79 years, 41.6% female), 19.1% underwent NCS at ≤30 days, 22.9% at 31 to 60 days, 16.7% at 61 to 90 days, and 41.3% at >90 days. After adjustment, the odds of MAEs were similar for operations performed at ≤30 days (adjusted OR [AOR]: 1.05; 95% confidence interval [CI]: 0.74-1.50), 31 to 60 days (AOR: 0.97; 95% CI: 0.71-1.31), and 61 to 90 days (AOR: 0.95; 95% CI: 0.67-1.34), with those at >90 days as reference. When examining the average marginal effect of the interval to surgery, risk-adjusted MAE rates were statistically similar across Δt groups for elective status and NCS risk category combinations. CONCLUSIONS: NCS within 30, 31 to 60, or 61 to 90 days after TAVR was not associated with increased odds of MAEs compared with operations after 90 days irrespective of NCS risk category or elective status. Our findings suggest that the interval between NCS and TAVR may not be an accurate predictor of MAE risk in this population.

11.
Circulation ; 125(8): 1005-13, 2012 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-22282327

RESUMO

BACKGROUND: With the availability of transcatheter aortic valve replacement, management of coronary artery disease in patients with severe aortic stenosis (AS) is posing challenges. Outcomes of percutaneous coronary intervention (PCI) in patients with severe AS and coronary artery disease remain unknown. We sought to compare the short-term outcomes of PCI in patients with and without AS. METHODS AND RESULTS: From our PCI database, we identified 254 patients with severe AS who underwent PCI between 1998 and 2008. Using propensity matching, we found 508 patients without AS who underwent PCI in the same period. The primary end point of 30-day mortality after PCI was similar in patients with and without severe AS (4.3% [11 of 254] versus 4.7% [24 of 508]; hazard ratio, 0.93; 95% confidence interval, 0.51-1.69; P=0.2). Patients with low ejection fraction (≤30%) and severe AS had a higher 30-day post-PCI mortality compared with those with an ejection fraction >30% (5.4% [7 of 45] versus 1.2% [4 of 209]; P<0.001). In addition, AS patients with high Society of Thoracic Surgeons score (≥10) had a higher 30-day post-PCI mortality than those with a Society of Thoracic Surgeons score <10 (10.4% [10 of 96] versus 0%; P<0.001). CONCLUSIONS: PCI can be performed in patients with severe symptomatic AS and coronary artery disease without an increased risk of short-term mortality compared with propensity-matched patients without AS. Patients with ejection fraction ≤30% and Society of Thoracic Surgeons score ≥10% are at a highest risk of 30-day mortality after PCI. This finding has significant implications in the management of severe coronary artery disease in high-risk severe symptomatic AS patients being considered for transcatheter aortic valve replacement.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/mortalidade , Índice de Gravidade de Doença , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Sociedades Médicas/normas , Cirurgia Torácica/normas
12.
Catheter Cardiovasc Interv ; 81(1): E1-8, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22508442

RESUMO

OBJECTIVES: To determine the role of percutaneous coronary intervention (PCI) and its impact on mortality in coronary artery disease (CAD). BACKGROUND: It's unclear whether PCI provides benefit in patients with CAD outside of acute settings. We sought to determine the role of PCI and its effect on mortality in patients with similar entry criteria to prior RCTs and compare outcomes with medical treatment. METHODS: Using institutional diagnostic catheterization database of consecutive patients undergoing coronary angiography from 1/2004 to 1/2010, we examined records for patients with a positive stress test and >70% coronary stenosis or symptoms of angina and >80% coronary stenosis. We excluded those with acute coronary syndromes, low ejection fraction (EF), history of CABG, and CABG following index catheterization. We stratified patients by treatment and performed unadjusted and propensity matched analyses. The outcome was all-cause mortality obtained from the social security death index. RESULTS: We identified 3,375 patients using study inclusion criteria. Mean age was 65 ± 11 years and 69% (n = 2,332) were men. Mean EF was 55% ± 8%. In the unadjusted cohort, 1,265 patients received medical management and 2,110 received PCI. The unadjusted analysis revealed significantly better survival in PCI patients (P < 0.0001) (HR: 0.51; 95% confidence interval (CI), 0.41-0.63). Propensity matching was performed for 1,580 patients and analysis showed better survival among patients receiving PCI (0 = 0.04) (HR: 0.74; 95% CI, 0.55-0.98). PCI continued to show better survival after excluding patients with malignancy (P = 0.03) and unstable angina (P = 0.007). CONCLUSIONS: This single center registry analysis demonstrated better survival in stable CAD patients undergoing PCI compared to medical management alone. These data suggest there may be a benefit of PCI beyond symptom relief. Future randomized trials are needed to further understand the role of PCI in broader patient populations.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Fatores Etários , Idoso , Angioplastia Coronária com Balão/mortalidade , Angioplastia Coronária com Balão/estatística & dados numéricos , Fármacos Cardiovasculares/uso terapêutico , Estudos de Casos e Controles , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Bases de Dados Factuais , Feminino , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores Sexuais , Stents , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos
13.
J Biomech ; 156: 111663, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37295168

RESUMO

With the current advances and expertise in biomedical device technologies, transcatheter heart valves (THVs) have been drawing significant attention. Various studies have been carried out on their durability and damage by dynamic loading in operational conditions. However, very few numerical investigations have been conducted to understand the effects of leaflet curvature and thickness on the crimping stresses which arise during the surgical preparation processes. In order to contribute to the current state of the art, a full heart valve model was presented, the leaflet curvature and thickness of which were then parameterized so as to understand the stress generation as a result of the crimping procedure during the surgical preparations. The results show that the existence of stresses is inevitable during the crimping procedure, which is a reduction factor for valve durability. Especially, stresses on the leaflets at the suture sites connected with the skirt were deduced to be critical and may result in leaflet ruptures after THV implantation.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Desenho de Prótese
14.
Eur Heart J Case Rep ; 7(9): ytad427, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37719001

RESUMO

Background: Bioprosthetic mitral valves on average have a median durability between 8 and 10 years. After the failure of a bioprosthetic valve, surgical replacement is often indicated. However, the options for those patients at high or prohibitive surgical risks are limited. Here, we describe a case of a successful trans-catheter mitral valve-in-valve (TMViV) replacement on venoarterial extracorporeal membrane oxygenation (VA-ECMO). Case summary: We describe a case of a 39-year-old female with a history notable for systemic lupus erythematosus, severe pulmonary arterial hypertension (now mixed pre and post) thought to be secondary to prior substance use, and infective endocarditis complicated by severe mitral stenosis status post-bioprosthetic mitral valve replacement who presented with symptoms of acute hypoxic respiratory failure secondary to severe bioprosthetic mitral valve stenosis. The patient had a prolonged hospital course complicated by a pulseless electrical activity arrest, (continuous renal replacement therapy) for acute renal failure, and hypertonic saline due to cerebral oedema. Due to her significant co-morbidities and haemodynamic instability with acute kidney injury and recent neurologic insult, the patient was thought not to be a good surgical candidate. However, given her young age and overall improved neurologic status, it was thought the patient could benefit from a TMViV with bi-ventricular support given her right- and left-sided heart failure and was placed on VA-ECMO in anticipation of a TMViV procedure for circulatory support. The patient underwent a successful TMViV replacement using a trans-septal approach with a 26 mm SAPIEN 3 valve and atrial septal defect closure with a 14 mm Amplatzer device on hospital Day 12. The patient was successfully de-cannulated from VA-ECMO on hospital Day 13. The patient had a prolonged hospital course but eventually had renal recovery and tracheostomy de-cannulation. A trans-thoracic echocardiogram prior to discharge was notable for a well-functioning valve and normal ejection fraction. The patient was discharged to a nursing home for further rehabilitation. Discussion: The gold standard for bioprosthetic mitral valve stenosis is surgical replacement of the valve. However, the options for those at high or prohibitive surgical risk are lacking. Recent studies have demonstrated TMViV is a safe alternative to surgical mitral valve redo cases in high-risk patients. To our knowledge, there are limited data on trans-catheter valve placement while on VA-ECMO. Successful implantation in our patient suggests that TMViV in a stenotic bioprosthesis is feasible in very high-risk patients with the use of VA-ECMO to support haemodynamics.

15.
JACC Case Rep ; 16: 101888, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37396330

RESUMO

We show the virtual simulation of the fluoroscopic location of the membranous septum using preprocedural cardiac computed tomographic data sets. Recognizing the risk distance before the procedure can help individualize implantation strategy to reduce the risk of atrioventricular conduction axis damage during transcatheter aortic valve replacement. (Level of Difficulty: Advanced.).

16.
Am J Cardiol ; 205: 120-125, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37597486

RESUMO

Asian American/Pacific Islanders (AAPIs) and Hispanics are growing minority United States populations, but are poorly represented in the cardiovascular literature. This study examines guideline adherence and outcomes in AAPIs and Hispanics compared with non-Hispanic Whites (NHWs) in a quaternary care center after inpatient percutaneous coronary intervention (PCI). The primary end points were inpatient post-PCI bleed, heart failure, cardiogenic shock, and all-cause mortality, whereas the secondary end point was the prescription rate of post-PCI guideline-directed medical therapy including aspirin, statins, P2Y12 receptor blockers, and cardiopulmonary rehabilitation. Intergroup differences were assessed through analysis of variance or two-way chi-square tests, and the association of race with binary outcomes was examined through logistic regression with NHW as the reference group. Compared with NHW, AAPIs, and Hispanics had higher odds of diabetes mellitus, and AAPIs had higher odds of hypertension and being on dialysis. Hispanics had higher odds of post-PCI mortality versus NHW, both in acute coronary syndrome (odds ratio [OR] 2.04, p = 0.03) and elective PCI (OR 2.51, p = 0.04). AAPI also trended toward higher mortality than NHW in both categories. AAPIs were found to have higher odds of statin prescription (OR 1.91, p = 0.04). Hispanics had lower odds of ticagrelor prescription versus NHW (OR 0.65, p = 0.04), and AAPIs trended toward such. No differences were found for cardiopulmonary rehabilitation prescriptions in groups. This study suggests that despite quality improvement efforts, disparities remain in postprocedural outcomes in minority groups in comparison with NHW.


Assuntos
Síndrome Coronariana Aguda , Insuficiência Cardíaca , Inibidores de Hidroximetilglutaril-CoA Redutases , Intervenção Coronária Percutânea , Humanos , Choque Cardiogênico , Síndrome Coronariana Aguda/cirurgia , Nativo Asiático-Americano do Havaí e das Ilhas do Pacífico , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico
17.
Tex Heart Inst J ; 50(1)2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36695735

RESUMO

BACKGROUND: Aortic valve replacement improves survival for patients with low-gradient aortic valve stenosis, but there is a paucity of data on postoperative quality of life for this population. METHODS: In a single-center retrospective analysis of 304 patients with severe aortic valve stenosis who underwent transcatheter aortic valve replacement, patients were divided into 4 groups based on mean pressure gradient, left ventricular ejection fraction, and stroke volume index. Using the Kansas City Cardiomyopathy Questionnaire-12, quality of life was assessed immediately before and 1 month after transcatheter aortic valve replacement. RESULTS: Most patients in the low-flow, low-gradient group were men; this group had higher relative rates of cardiovascular disease and type 2 diabetes than the paradoxical low-flow, low-gradient group; the normal-flow, low-gradient group; and the high-gradient group. All-cause mortality did not differ significantly among the groups at 1 month after surgery, and all groups experienced a significant improvement in quality-of-life scores after surgery. The mean improvement was 27 points in the low-flow, low-gradient group, 25 points in the paradoxical low-flow, low-gradient group, 30 points in the normal-flow, low-gradient group, and 30 points in the high-gradient group (all P < .001). CONCLUSION: Quality of life improves significantly across all subgroups of aortic valve stenosis after trans-catheter aortic valve replacement, regardless of flow characteristics or aortic valve gradients.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus Tipo 2 , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
18.
Chest ; 163(1): 216-225, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35926721

RESUMO

BACKGROUND: The sex differences in use, safety outcomes, and health-care resource use of patients with pulmonary embolism (PE) undergoing percutaneous pulmonary artery thrombectomy are not well characterized. RESEARCH QUESTION: What are the sex differences in outcomes for patients diagnosed with PE who undergo percutaneous pulmonary artery thrombectomy? STUDY DESIGN AND METHODS: This retrospective cross-sectional study used national inpatient claims data to identify patients in the United States with a discharge diagnosis of PE who underwent percutaneous thrombectomy between January 2016 and December 2018. We evaluated the demographics, comorbidities, safety outcomes (in-hospital mortality), and health-care resource use (discharge to home, length of stay, and hospital charges) of patients with PE undergoing percutaneous thrombectomy. RESULTS: Among 1,128,904 patients with a diagnosis of PE between 2016 and 2018, 5,160 patients (0.5%) underwent percutaneous pulmonary artery thrombectomy. When compared with male patients, female patients showed higher procedural bleeding (16.9% vs 11.2%; P < .05), required more blood transfusions (11.9% vs 5.7%; P < .05), and experienced more vascular complications (5.0% vs 1.5%; P < .05). Women experienced higher in-hospital mortality (16.9% vs 9.3%; adjusted OR, 1.9; 95% CI, 1.2-3.0; P = .003) when compared with men. Although length of stay and hospital charges were similar to those of men, women were less likely to be discharged home after surviving hospitalization (47.9% vs 60.3%; adjusted OR, 0.7; 95% CI, 0.50-0.99; P = .04). INTERPRETATION: In this large nationwide cohort, women with PE who underwent percutaneous thrombectomy showed higher morbidity and in-hospital mortality compared with men.


Assuntos
Artéria Pulmonar , Embolia Pulmonar , Humanos , Feminino , Masculino , Estados Unidos/epidemiologia , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Estudos Transversais , Caracteres Sexuais , Resultado do Tratamento , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/cirurgia , Embolia Pulmonar/etiologia , Trombectomia/efeitos adversos
19.
Clin Cardiol ; 45(10): 977-985, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36193709

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly offered for aortic stenosis (AS) treatment in patients with a history of cancer. The impact of frailty on outcomes in this specific patient population is not well described. HYPOTHESIS: Frailty is associated with mortality and poorer quality of life (QOL) outcomes in patients undergoing TAVR with a history of cancer. METHODS: This retrospective single center cohort study included AS patients who underwent TAVR from August 1, 2012 to May 15, 2020. Frailty was measured using serum albumin, hemoglobin, gait speed, functional dependence, and cognitive impairment. The primary outcome was a composite of all-cause mortality and QOL at 1 year. A poor primary outcome was defined as either all-cause mortality, Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS) score <45 or a KCCQ-OS score decline of ≥10 points from baseline. Regression analysis was used to determine the impact of frailty on the primary outcome. RESULTS: The study population was stratified into active/recent cancer (n = 107), remote cancer (n = 85), and non-cancer (n = 448). Univariate analysis of each cohort showed that frailty was associated with the primary outcome only in the non-cancer cohort (p = .004). Multivariate analysis showed that cancer history was not associated with a poor primary outcome, whereas frailty was (1.7 odds ratio, 95% confidence interval [CI]: 1.1-2.8; p = .028). CONCLUSIONS: Frailty is associated with mortality and poor QOL in the overall and non-cancer cohorts. Further investigation is warranted to understand frailty's effect on the cancer population. Frailty should be heavily considered during TAVR evaluation.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Neoplasias , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Fragilidade/complicações , Fragilidade/diagnóstico , Humanos , Neoplasias/complicações , Qualidade de Vida , Estudos Retrospectivos , Fatores de Risco , Albumina Sérica , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Am J Cardiol ; 166: 122-126, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34949471

RESUMO

Fractional flow reserve (FFR) determines the functional significance of epicardial stenoses assuming negligible venous pressure (Pv) and microvascular resistance. However, these assumptions may be invalid in end-stage liver disease (ESLD) because of fluctuating Pv and vasodilation. Accordingly, all patients with ESLD who underwent right-sided cardiac catheterization and coronary angiography with FFR as part of their orthotopic liver transplantation evaluation between 2013 and 2018 were included in the present study. Resting mean distal coronary pressure (Pd)/mean aortic pressure (Pa), FFR, and Pv were measured. FFR accounting for Pv (FFR - Pv) was defined as (Pd - Pv)/(Pa - Pv). The hyperemic effect of adenosine was defined as resting Pd/Pa - FFR. The primary outcome was all-cause mortality at 1 year. In 42 patients with ESLD, 49 stenoses were interrogated by FFR (90% were <70% diameter stenosis). Overall, the median model for ESLD score was 16.5 (10.8 to 25.5), FFR was 0.87 (0.81 to 0.94), Pv was 8 mm Hg (4 to 14), FFR-Pv was 0.86 (0.80 to 0.94), and hyperemic effect of adenosine was 0.06 (0.02 to 0.08). FFR-Pv led to the reclassification of 1 stenosis as functionally significant. There was no significant correlation between the median model for ESLD score and the hyperemic effect of adenosine (R = 0.10). At 1 year, 13 patients had died (92% noncardiac in etiology), and patients with FFR ≤0.80 had significantly higher all-cause mortality (73% vs 17%, p = 0.001. In conclusion, in patients with ESLD who underwent orthotopic liver transplantation evaluation, Pv has minimal impact on FFR, and the hyperemic effect of adenosine is preserved. Furthermore, even in patients with the predominantly angiographically-intermediate disease, FFR ≤0.80 was an independent predictor of all-cause mortality.


Assuntos
Estenose Coronária , Doença Hepática Terminal , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Adenosina , Cateterismo Cardíaco , Constrição Patológica , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/cirurgia , Vasos Coronários , Doença Hepática Terminal/cirurgia , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA