1.
J Biomed Mater Res B Appl Biomater ; 79(2): 263-7, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16649169

RESUMO

The use of new materials in knee arthroplasty demands a way in which to accurately quantify wear in retrieved components. Methods such as damage scoring, coordinate measurement, and in vivo wear analysis have been used in the past. The limitations in these methods illustrate a need for a different methodology that can accurately quantify wear, which is relatively easy to perform and uses a minimal amount of expensive equipment. Off-the-shelf digital photogrammetry represents a potentially quick and easy alternative to what is readily available. Eighty tibial inserts were visually examined for front and backside wear and digitally photographed in the presence of two calibrated reference fields. All images were segmented (via manual and automated algorithms) using Adobe Photoshop and National Institute of Health ImageJ. Finally, wear was determined using ImageJ and Rhinoceros software. The absolute accuracy of the method and repeatability/reproducibility by different observers were measured in order to determine the uncertainty of wear measurements. To determine if variation in wear measurements was due to implant design, 35 implants of the three most prevalent designs were subjected to retrieval analysis. The overall accuracy of area measurements was 97.8%. The error in automated segmentation was found to be significantly lower than that of manual segmentation. The photogrammetry method was found to be reasonably accurate and repeatable in measuring 2-D areas and applicable to determining wear. There was no significant variation in uncertainty detected among different implant designs. Photogrammetry has a broad range of applicability since it is size- and design-independent. A minimal amount of off-the-shelf equipment is needed for the procedure and no proprietary knowledge of the implant is needed.


Assuntos
Materiais Biocompatíveis , Prótese do Joelho , Fotogrametria , Humanos , Teste de Materiais , Polietilenos
2.
J Biomech ; 22(6-7): 583-95, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2808442

RESUMO

We have developed a system to measure initial conditions in the javelin throw rapidly enough to be used by the thrower for feedback in performance improvement. The system consists of three subsystems whose main tasks are: (A) acquisition of automatically digitized high speed (200 Hz) video x, y position data for the first 0.1-0.2 s of the javelin flight after release (B) estimation of five javelin release conditions from the x, y position data and (C) graphical presentation to the thrower of these release conditions and a simulation of the subsequent flight together with optimal conditions and flight for the sam release velocity. The estimation scheme relies on a simulation model and is at least an order of magnitude more accurate than previously reported measurements of javelin release conditions. The system provides, for the first time ever in any throwing event, the ability to critique nearly instantly in a precise, quantitative manner the crucial factors in the throw which determine the range. This should be expected to much greater control and consistency of throwing variables by athletes who use system and could even lead to an evolution of new throwing techniques.


Assuntos
Ergonomia , Atletismo , Algoritmos , Fenômenos Biomecânicos , Simulação por Computador , Retroalimentação , Humanos , Modelos Biológicos , Estudos de Tempo e Movimento , Gravação de Videoteipe
3.
J Sports Sci ; 19(5): 349-58, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11354614

RESUMO

The aim of this study was to develop a new method for the determination of lift on spinning baseballs. Inertial trajectories of (a) ball surface markers during the first metre of flight and (b) the centre of mass trajectory near home-plate were measured in a pitch using high-speed video. A theoretical model was developed, incorporating aerodynamic Magnus-Robins lift, drag and cross forces, which predicts the centre of mass and marker trajectories. Parameters including initial conditions and aerodynamic coefficients were estimated iteratively by minimizing the error between predicted and measured trajectories. We compare the resulting lift coefficients and spin parameter values with those of previous studies. Lift on four-seam pitches can be as much as three times that of two-seam pitches, although this disparity is reduced for spin parameters greater than 0.4.


Assuntos
Beisebol , Física , Equipamentos Esportivos , Modelos Teóricos , Física/estatística & dados numéricos , Projetos de Pesquisa , Estatística como Assunto