RESUMO
BACKGROUND: Measuring fluid status during intraoperative hemorrhage is challenging, but detection and quantification of fluid overload is far more difficult. Using a porcine model of hemorrhage and over-resuscitation, it is hypothesized that centrally obtained hemodynamic parameters will predict volume status more accurately than peripherally obtained vital signs. METHODS: Eight anesthetized female pigs were hemorrhaged at 30 ml/min to a blood loss of 400 ml. After each 100 ml of hemorrhage, vital signs (heart rate, systolic blood pressure, mean arterial pressure, diastolic blood pressure, pulse pressure, pulse pressure variation) and centrally obtained hemodynamic parameters (mean pulmonary artery pressure, pulmonary capillary wedge pressure, central venous pressure, cardiac output) were obtained. Blood volume was restored, and the pigs were over-resuscitated with 2,500 ml of crystalloid, collecting parameters after each 500-ml bolus. Hemorrhage and resuscitation phases were analyzed separately to determine differences among parameters over the range of volume. Conformity of parameters during hemorrhage or over-resuscitation was assessed. RESULTS: During the course of hemorrhage, changes from baseline euvolemia were observed in vital signs (systolic blood pressure, diastolic blood pressure, and mean arterial pressure) after 100 ml of blood loss. Central hemodynamic parameters (mean pulmonary artery pressure and pulmonary capillary wedge pressure) were changed after 200 ml of blood loss, and central venous pressure after 300 ml of blood loss. During the course of resuscitative volume overload, changes were observed from baseline euvolemia in mean pulmonary artery pressure and central venous pressure after 500-ml resuscitation, in pulmonary capillary wedge pressure after 1,000-ml resuscitation, and cardiac output after 2,500-ml resuscitation. In contrast to hemorrhage, vital sign parameters did not change during over-resuscitation. The strongest linear correlation was observed with pulmonary capillary wedge pressure in both hemorrhage (r2 = 0.99) and volume overload (r2 = 0.98). CONCLUSIONS: Pulmonary capillary wedge pressure is the most accurate parameter to track both hemorrhage and over-resuscitation, demonstrating the unmet clinical need for a less invasive pulmonary capillary wedge pressure equivalent.
Assuntos
Soluções Cristaloides/administração & dosagem , Hidratação/efeitos adversos , Hemodinâmica , Hemorragia/fisiopatologia , Animais , Volume Sanguíneo , Modelos Animais de Doenças , Feminino , Ressuscitação , Suínos , Sinais VitaisRESUMO
BACKGROUND: A perioperative surgical home, the Anesthesia Perioperative Care Service (APCS), was created to execute enhanced recovery after surgery pathways for total knee and total hip arthroplasty patients at the Tennessee Valley Health System Nashville VA Medical Center. We hypothesized that the APCS would be associated with reduced length of stay, in-hospital and post-discharge opioid exposure, costs, and hospital readmissions. METHODS: Data were collected for all patients admitted to the Nashville VA Medical Center following their respective surgery, for 400 days after the initiation of the APCS and for a 400-day period prior. This cohort study was based on a quality improvement project set up at the initiation of the service. The adjusted effect on each quantitative outcome was evaluated using proportional odds logistic regression methods. In addition, each regression analysis was performed in segmented regression fashion to identify changes in the outcomes over time. RESULTS: We included 282 patients in our cohort-96 prior and 186 post-implementation. Median hospital length of stay, intravenous (IV) and per os (PO) inpatient opioid administration, outpatient opioid quantity, and total days of supply were all reduced in the cohort cared for by the APCS. After adjusting for potential cofounders and evaluated outcome over time, the APCS remained independently associated with a reduction of hospital length of stay of one day (95% confidence interval, 0.09 to 1.97; P = 0.05) and with decreased IV and PO inpatient opioid administration, while continuing to show no increase in hospital readmissions. CONCLUSIONS: This cohort study showed significant improvements in important post-surgical outcomes after total knee and hip arthroplasty that were associated with the implementation of an APCS.
RéSUMé: CONTEXTE: Un centre de soins chirurgicaux périopératoires (perioperative surgical home), le Service de soins périopératoires en anesthésie (SSPA), a été créé pour mettre en Åuvre des trajectoires de soins de récupération rapide après la chirurgie pour les patients ayant subi une arthroplastie totale du genou ou de la hanche au centre médical Tennessee Valley Health System Nashville VA Medical Center. Nous avons émis l'hypothèse que le SSPA serait associé à une réduction de la durée du séjour, de l'exposition aux opioïdes à l'hôpital et après le congé, ainsi qu'à une diminution des coûts et des réadmissions à l'hôpital. MéTHODE: Les données ont été recueillies pour tous les patients admis au centre médical Nashville VA Medical Center après leur chirurgie respective, pendant 400 jours avant et après la création du SSPA. Cette étude de cohorte se fondait sur un projet d'amélioration de la qualité mis en place lors de l'inauguration du service. L'effet ajusté sur chaque résultat quantitatif a été évalué à l'aide de méthodes de régression logistique proportionnelles. De plus, chaque analyse de régression a été effectuée de façon segmentée afin d'identifier l'évolution des résultats au fil du temps. RéSULTATS: Nous avons inclus 282 patients dans notre cohorte 96 avant et 186 après la mise en Åuvre. La durée médiane du séjour à l'hôpital, l'administration d'opioïdes par voie intraveineuse (IV) et per os (PO) pendant le séjour hospitalier, la quantité d'opioïdes en ambulatoire et sa durée en jours ont tous été réduites dans la cohorte prise en charge par le SSPA. Après avoir procédé à des ajustements pour tenir compte des facteurs de confusion potentiels et évalué l'évolution des résultats au fil du temps, le SSPA est demeuré indépendamment associé à une réduction de la durée de séjour à l'hôpital d'un jour (intervalle de confiance 95 %, 0,09 à 1,97; P = 0,05), à une réduction de l'administration d'opioïdes IV et PO durant le séjour, et il n'y a eu aucune augmentation des réadmissions à l'hôpital. CONCLUSION: Cette étude de cohorte a montré des améliorations significatives en matière de résultats post-chirurgicaux importants après une arthroplastie totale du genou et de la hanche associés à la mise en Åuvre d'un SSPA.
Assuntos
Anestesia , Artroplastia de Quadril , Artroplastia do Joelho , Veteranos , Assistência ao Convalescente , Estudos de Coortes , Hospitais , Humanos , Tempo de Internação , Alta do Paciente , Melhoria de QualidadeRESUMO
Importance: For critically ill adults undergoing emergency tracheal intubation, failure to intubate the trachea on the first attempt occurs in up to 20% of cases and is associated with severe hypoxemia and cardiac arrest. Whether using a tracheal tube introducer ("bougie") increases the likelihood of successful intubation compared with using an endotracheal tube with stylet remains uncertain. Objective: To determine the effect of use of a bougie vs an endotracheal tube with stylet on successful intubation on the first attempt. Design, Setting, and Participants: The Bougie or Stylet in Patients Undergoing Intubation Emergently (BOUGIE) trial was a multicenter, randomized clinical trial among 1102 critically ill adults undergoing tracheal intubation in 7 emergency departments and 8 intensive care units in the US between April 29, 2019, and February 14, 2021; the date of final follow-up was March 14, 2021. Interventions: Patients were randomly assigned to use of a bougie (n = 556) or use of an endotracheal tube with stylet (n = 546). Main Outcomes and Measures: The primary outcome was successful intubation on the first attempt. The secondary outcome was the incidence of severe hypoxemia, defined as a peripheral oxygen saturation less than 80%. Results: Among 1106 patients randomized, 1102 (99.6%) completed the trial and were included in the primary analysis (median age, 58 years; 41.0% women). Successful intubation on the first attempt occurred in 447 patients (80.4%) in the bougie group and 453 patients (83.0%) in the stylet group (absolute risk difference, -2.6 percentage points [95% CI, -7.3 to 2.2]; P = .27). A total of 58 patients (11.0%) in the bougie group experienced severe hypoxemia, compared with 46 patients (8.8%) in the stylet group (absolute risk difference, 2.2 percentage points [95% CI, -1.6 to 6.0]). Esophageal intubation occurred in 4 patients (0.7%) in the bougie group and 5 patients (0.9%) in the stylet group, pneumothorax was present after intubation in 14 patients (2.5%) in the bougie group and 15 patients (2.7%) in the stylet group, and injury to oral, glottic, or thoracic structures occurred in 0 patients in the bougie group and 3 patients (0.5%) in the stylet group. Conclusions and Relevance: Among critically ill adults undergoing tracheal intubation, use of a bougie did not significantly increase the incidence of successful intubation on the first attempt compared with use of an endotracheal tube with stylet. Trial Registration: ClinicalTrials.gov Identifier: NCT03928925
Assuntos
Intubação Intratraqueal/instrumentação , Adulto , Idoso , Estado Terminal , Feminino , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Masculino , Pessoa de Meia-Idade , Saturação de OxigênioRESUMO
BACKGROUND: Outpatient monitoring and management of patients with heart failure (HF) reduces hospitalizations and health care costs. However, the availability of noninvasive approaches to assess congestion is limited. Noninvasive venous waveform analysis (NIVA) uses a unique physiologic signal, the morphology of the venous waveform, to assess intracardiac filling pressures. This study is a proof of concept analysis of the correlation between NIVA value and pulmonary capillary wedge pressure (PCWP) and the ability of the NIVA value to predict PCWP > 18 mmHg in subjects undergoing elective right heart catheterization (RHC). PCWP was also compared across common clinical correlates of congestion. METHODS AND RESULTS: A prototype NIVA device, which consists of a piezoelectric sensor placed over the skin on the volar aspect of the wrist, connected to a data-capture control box, was used to collect venous waveforms in 96 patients during RHC. PCWP was collected at end-expiration by an experienced cardiologist. The venous waveform signal was transformed to the frequency domain (Fourier transform), where a ratiometric algorithm of the frequencies of the pulse rate and its harmonics was used to derive a NIVA value. NIVA values were successfully captured in 83 of 96 enrolled patients. PCWP ranged from 4-40 mmHg with a median of 13 mmHg. NIVA values demonstrated a linear correlation with PCWP (râ¯=â¯0.69, P < 0.05). CONCLUSIONS: This observational proof-of-concept study using a prototype NIVA device demonstrates a moderate correlation between NIVA value and PCWP in patients undergoing RHC. NIVA, thus, represents a promising developing technology for noninvasive assessment of congestion in spontaneously breathing patients.
Assuntos
Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Pressão Propulsora Pulmonar/fisiologia , Análise de Onda de Pulso/métodos , Volume Sistólico/fisiologia , Adulto , Idoso , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Componente Principal/métodosRESUMO
BACKGROUND: Accurate assessment of volume status to direct dialysis remains a clinical challenge. Despite current attempts at volume-directed dialysis, inadequate dialysis and intradialytic hypotension (IDH) are common occurrences. Peripheral venous waveform analysis has recently been developed as a method to accurately determine intravascular volume status through algorithmic quantification of changes in the waveform that occur at different volume states. A noninvasive method to capture peripheral venous signals is described (Non-Invasive Venous waveform Analysis, NIVA). The objective of this proof-of-concept study was to characterize changes in NIVA signal with dialysis. We hypothesized that there would be a change in signal after dialysis and that the rate of intradialytic change in signal would be predictive of IDH. METHODS: Fifty subjects undergoing inpatient hemodialysis were enrolled. A 10-mm piezoelectric sensor was secured to the middle volar aspect of the wrist on the extremity opposite to the access site. Signals were obtained fifteen minutes before, throughout, and up to fifteen minutes after hemodialysis. Waveforms were analyzed after a fast Fourier transformation and identification of the frequencies corresponding to the cardiac rate, with a NIVA value generated based on the weighted powers of these frequencies. RESULTS: Adequate quality (signal to noise ratio > 20) signals pre- and post- dialysis were obtained in 38 patients (76%). NIVA values were significantly lower at the end of dialysis compared to pre-dialysis levels (1.203 vs 0.868, p < 0.05, n = 38). Only 16 patients had adequate signals for analysis throughout dialysis, but in this small cohort the rate of change in NIVA value was predictive of IDH with a sensitivity of 80% and specificity of 100%. CONCLUSIONS: This observational, proof-of-concept study using a NIVA prototype device suggests that NIVA represents a novel and non-invasive technique that with further development and improvements in signal quality may provide static and continuous measures of volume status to assist with volume directed dialysis and prevent intradialytic hypotension.
Assuntos
Volume Sanguíneo , Hipotensão/etiologia , Monitorização Fisiológica/métodos , Diálise Renal/efeitos adversos , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Volume Sanguíneo/fisiologia , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Estudo de Prova de Conceito , Sensibilidade e Especificidade , Razão Sinal-RuídoRESUMO
BACKGROUND: To determine the feasibility of peripheral intravenous volume analysis (PIVA) of venous waveforms for assessing volume overload in patients admitted to the hospital with acute decompensated heart failure (ADHF). METHODS: Venous waveforms were captured from a peripheral intravenous catheter in subjects admitted for ADHF and healthy age-matched controls. Admission PIVA signal, brain natriuretic peptide, and chest radiographic measurements were related to the net volume removed during diuresis. RESULTS: ADHF patients had a significantly greater PIVA signal on admission compared with the control group (P = .0013, n = 18). At discharge, ADHF patients had a PIVA signal similar to the control group. PIVA signal, not brain natriuretic peptide or chest radiographic measures, accurately predicted the amount of volume removed during diuresis (R2 = 0.781, n = 14). PIVA signal at time of discharge greater than 0.20, demonstrated 83.3% 120-day readmission rate. CONCLUSIONS: This study demonstrates the feasibility of PIVA for assessment of volume overload in patients admitted to the hospital with ADHF.
Assuntos
Volume Sanguíneo/fisiologia , Insuficiência Cardíaca/fisiopatologia , Pacientes Internados , Volume Sistólico/fisiologia , Veias/fisiopatologia , Doença Aguda , Cateterismo Periférico , Diurese/fisiologia , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Projetos PilotoRESUMO
PURPOSE: To evaluate the accuracy and reproducibility of quantitative chemical shift-encoded (CSE) MRI to quantify proton-density fat-fraction (PDFF) in a fat-water phantom across sites, vendors, field strengths, and protocols. METHODS: Six sites (Philips, Siemens, and GE Healthcare) participated in this study. A phantom containing multiple vials with various oil/water suspensions (PDFF:0%-100%) was built, shipped to each site, and scanned at 1.5T and 3T using two CSE protocols per field strength. Confounder-corrected PDFF maps were reconstructed using a common algorithm. To assess accuracy, PDFF bias and linear regression with the known PDFF were calculated. To assess reproducibility, measurements were compared across sites, vendors, field strengths, and protocols using analysis of covariance (ANCOVA), Bland-Altman analysis, and the intraclass correlation coefficient (ICC). RESULTS: PDFF measurements revealed an overall absolute bias (across sites, field strengths, and protocols) of 0.22% (95% confidence interval, 0.07%-0.38%) and R2 > 0.995 relative to the known PDFF at each site, field strength, and protocol, with a slope between 0.96 and 1.02 and an intercept between -0.56% and 1.13%. ANCOVA did not reveal effects of field strength (P = 0.36) or protocol (P = 0.19). There was a significant effect of vendor (F = 25.13, P = 1.07 × 10-10 ) with a bias of -0.37% (Philips) and -1.22% (Siemens) relative to GE Healthcare. The overall ICC was 0.999. CONCLUSION: CSE-based fat quantification is accurate and reproducible across sites, vendors, field strengths, and protocols. Magn Reson Med 77:1516-1524, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Assuntos
Tecido Adiposo/diagnóstico por imagem , Água Corporal/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Desenho de Equipamento , Análise de Falha de Equipamento , Prótons , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Physician-led perioperative surgical home models are developing as a method for improving the American health care system. These models are novel, team-based approaches that help to provide continuity of care throughout the perioperative period. Another avenue for improving care for surgical patients is the use of enhanced recovery after surgery pathways. These are well-described methods that have shown to improve perioperative outcomes. An established perioperative surgical home model can help implementation, efficiency, and adherence to enhanced recovery after surgery pathways. For these reasons, the Tennessee Valley Healthcare System, Nashville Veterans Affairs Medical Center created an Anesthesiology Perioperative Care Service that provides comprehensive care to surgical patients from their preoperative period through the continuum of their hospital course and postdischarge follow-up. In this brief report, we describe the development, implementation, and preliminary outcomes of the service.
Assuntos
Serviço Hospitalar de Anestesia/organização & administração , Anestesia/métodos , Prestação Integrada de Cuidados de Saúde/organização & administração , Hospitais de Veteranos , Assistência Centrada no Paciente/organização & administração , Avaliação de Processos em Cuidados de Saúde/organização & administração , United States Department of Veterans Affairs , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Organizacionais , Desenvolvimento de Programas , Avaliação de Programas e Projetos de Saúde , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Fluxo de TrabalhoRESUMO
PURPOSE OF REVIEW: The purpose of this review is to summarize the current state of perioperative medicine, including the perioperative surgical home (PSH) and enhanced recovery after surgery pathways (ERAS) as well as the educational implications of these concepts for current and future anesthesiology trainees. RECENT FINDINGS: Although there is significant, ongoing discussion surrounding the structural concept of the PSH, there remains little clinical evidence to support its development. On the other hand, publications surrounding ERAS principles continue to show clinical benefit in reducing length of stay, cost, and perioperative complications for a variety of surgical populations. In this milieu, perioperative medicine is increasingly being recognized as its own specialty in perioperative care that encompasses, but is larger than, ERAS. SUMMARY: There is sufficient evidence to support widespread adoption of ERAS principles, although the specifics of local implementation may vary from site to site. There is significant uncertainty as to what the PSH actually is. However, perioperative medicine is a defined specialty in medicine that overlaps significantly with anesthesiology core training and practice and will be a significant focus in future education, research, and clinical care provided by anesthesiologists.
Assuntos
Anestesiologia/educação , Educação Médica , Assistência Centrada no Paciente/métodos , Assistência Perioperatória/tendências , Recuperação de Função Fisiológica , HumanosRESUMO
This protocol outlines an acute respiratory distress model utilizing centrally administered oleic acid infusion in Yorkshire pigs. Prior to experimentation, each pig underwent general anesthesia, endotracheal intubation, and mechanical ventilation, and was equipped with bilateral jugular vein central vascular access catheters. Oleic acid was administered through a dedicated pulmonary artery catheter at a rate of 0.2 mL/kg/h. The infusion lasted for 60-120 min, inducing respiratory distress. Throughout the experiment, various parameters including heart rate, respiratory rate, arterial blood pressure, central venous pressure, pulmonary artery pressure, pulmonary capillary wedge pressure, end-tidal carbon dioxide, peak airway pressures, and plateau pressures were monitored. Around the 60 min mark, decreases in partial arterial oxygen pressure (PaO2) and fraction of oxygen-saturated hemoglobin (SpO2) were observed. Periodic hemodynamic instability, accompanied by acute increases in pulmonary artery pressures, occurred during the infusion. Post-infusion, histological analysis of the lung parenchyma revealed changes indicative of parenchymal damage and acute disease processes, confirming the effectiveness of the model in simulating acute respiratory decompensation.
Assuntos
Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Animais , Suínos , Ácido Oleico , Hemodinâmica , OxigênioRESUMO
This article reviews the evolution of noninvasive hemodynamic monitoring technologies, highlighting their importance in perioperative and critical care settings. Initially dominated by invasive methods, the field has shifted toward noninvasive techniques to reduce risks and improve patient safety. These advancements encompass various technologies, including bioimpedance/bioreactance, pulse contour analysis, and photoplethysmography, offering anesthesiologists dynamic tools for patient management. The article explores historical developments, traditional and advanced noninvasive monitors, and future trends, emphasizing the potential of integrating artificial intelligence and wearable technology in patient care.
Assuntos
Monitorização Hemodinâmica , Humanos , Monitorização Hemodinâmica/métodos , Monitorização Hemodinâmica/instrumentação , Hemodinâmica/fisiologia , Fotopletismografia/métodos , Dispositivos Eletrônicos Vestíveis , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Inteligência Artificial , Cuidados Críticos/métodosRESUMO
This protocol describes an acute volume overload porcine model for adult Yorkshire pigs and piglets. Both swine ages undergo general anesthesia, endotracheal intubation, and mechanical ventilation. A central venous catheter and an arterial catheter are placed via surgical cutdown in the external jugular vein and carotid artery, respectively. A pulmonary artery catheter is placed through an introducer sheath of the central venous catheter. PlasmaLyte crystalloid solution is then administered at a rate of 100 mL/min in adult pigs and at 20 mL/kg boluses over 10 min in piglets. Hypervolemia is achieved either at 15% decrease in cardiac output or at 5 L in adult pigs and at 500 mL in piglets. Hemodynamic data, such as heart rate, respiratory rate, end-tidal carbon dioxide, fraction of oxygen-saturated hemoglobin, arterial blood pressure, central venous pressure, pulmonary artery pressure, pulmonary capillary wedge pressure, partial arterial oxygen pressure, lactate, pH, base excess, and pulmonary artery fraction of oxygen-saturated hemoglobin, are monitored during experimentation. Preliminary data observed with this model has demonstrated statistically significant changes and strong linear regressions between central hemodynamic parameters and acute volume overload in adult pigs. Only pulmonary capillary wedge pressure demonstrated both a linear regression and a statistical significance to acute volume overload in piglets. These models can aid scientists in the discovery of age-appropriate therapeutic and monitoring strategies to understand and prevent acute volume overload.
Assuntos
Hemodinâmica , Respiração Artificial , Humanos , Adulto , Criança , Animais , Suínos , Débito Cardíaco/fisiologia , Oxigênio , HemoglobinasRESUMO
Background Animal models of distributive hypotension and resuscitation allow the assessment of hemodynamic monitoring modalities and resuscitation strategies. The fluid-first paradigm for resuscitation is currently being challenged with clinical trials. In this investigation, venous return and perfusion are assessed, and full hemodynamics are characterized, in a porcine model of endotoxemic hypotension with and without fluid pre-loading. Methods Two groups of six pigs had the induction of standardized endotoxemic hypotension ("critical hypotension"). Group 1 underwent four 10 cc/kg crystalloid boluses, and Group 2 was not fluid pre-resuscitated. Both groups underwent progressive norepinephrine (NE) up-titration to 0.25 mcg/kg/minute over 30 minutes. Vital signs, central parameters, and laboratory values were obtained at baseline, "critical hypotension," after each bolus and during NE administration. Results Endotoxemia decreased the systemic vascular resistance (SVR) in Group 1 (1031±106 dyn/s/cm-5 versus 738±258 dyn/s/cm-5; P=0.03) and Group 2 (1121±196 dyn/s/cm-5 versus 759±342 dyn/s/cm-5; P=0.003). In Group 1, the four fluid boluses decreased heart rate (HR), pulmonary capillary wedge pressure (PCWP), and central venous pressure (CVP) (P<0.05). No changes were observed in blood pressure, cardiac output (CO), or lactate. NE up-titration increased HR in Group 1 and decreased CVP in both groups. Higher final CVP (11 {3} versus 4 {4} mmHg; P=0.01) and PCWP (5 {1} versus 2 {2} mmHg; P=0.005) values were observed in Group 1 relative to Group 2, reflecting increased venous return. Conclusions Porcine endotoxemic hypotension and resuscitation were robustly characterized. In this model, fluid loading improved venous return with NE, though perfusion (CO) was preserved by increased NE-induced chronotropy.
RESUMO
Introduction: A cornerstone of heart failure assessment is the right heart catheterization and the pulmonary capillary wedge pressure measurement it can provide. Clinical and hemodynamic parameters such as weight and jugular venous distention are less invasive measures often used to diagnose, manage, and treat these patients. To date, there is little data looking at the association of these key parameters to measured pulmonary capillary wedge pressure (PCWP). This is a large, retrospective, secondary analysis of a right heart catheterization database comparing clinical and hemodynamic parameters against measured PCWP in heart failure patients. Methods: A total of 538 subjects were included in this secondary analysis. Spearman's Rho analysis of each clinical and hemodynamic variable was used to compare their association to the documented PCWP. Variables analyzed included weight, body mass index (BMI), jugular venous distention (JVD), creatinine, edema grade, right atrial pressure (RAP), pulmonary artery systolic pressure (PASP), systemic vascular resistance, pulmonary vascular resistance, cardiac output (thermal and Fick), systolic blood pressure, diastolic blood pressure, heart rate, respiratory rate, oxygen saturation (SpO2), and pulmonary artery diastolic pressure (PADP). Results: Ten out of 17 selected parameters had a statistically significant association with measured PCWP values. PADP had the strongest association (0.73, p<0.0001), followed by RAP and PASP (0.69, p<0.0001 and 0.67, p<0.0001, respectively). Other significant parameters included weight (0.2, p<0.001), BMI (0.2, p<0.001), SpO2 (-0.17, p<0.0091), JVD (0.24, p<0.005) and edema grade (0.2, p<0.0001). Conclusion: This retrospective analysis clarifies the associations of commonly used clinical and hemodynamic parameters to the clinically used gold standard for volume assessment in heart failure patients, PCWP.
RESUMO
BACKGROUND: Cardiac output (CO) is a valuable proxy for perfusion, and governs volume responsiveness during resuscitation from distributive shock. The underappreciated venous system has nuanced physiology that confers valuable hemodynamic information. In this investigation, deconvolution of the central venous waveform by the fast Fourier transformation (FFT) algorithm is performed to assess its ability to constitute a CO surrogate in a porcine model of endotoxemia-induced distributive hypotension and resuscitation. STUDY DESIGN: Ten pigs were anesthetized, catheterized, and intubated. A lipopolysaccharides infusion protocol was used to precipitate low systemic vascular resistance hypotension. Four crystalloid boluses (10 cc/kg) were then given in succession, after which heart rate, mean arterial pressure, thermodilution-derived CO, central venous pressure (CVP), and the central venous waveform were collected, the last undergoing fast Fourier transformation analysis. The amplitude of the fundamental frequency of the central venous waveform's cardiac wave (f0-CVP) was obtained. Heart rate, mean arterial pressure, CVP, f0-CVP, and CO were plotted over the course of the boluses to determine whether f0-CVP tracked with CO better than the vital signs, or than CVP itself. RESULTS: Distributive hypotension to a 25% mean arterial pressure decrement was achieved, with decreased systemic vascular resistance (mean 918 ± 227 [SD] dyne/s/cm-5 vs 685 ± 180 dyne/s/cm-5; p = 0.038). Full hemodynamic parameters characterizing this model were reported. Slopes of linear regression lines of heart rate, mean arterial pressure, CVP, f0-CVP, and CO were -2.8, 1.7, 1.8, 0.40, and 0.35, respectively, demonstrating that f0-CVP values closely track with CO over the 4-bolus range. CONCLUSIONS: Fast Fourier transformation analysis of the central venous waveform may allow real-time assessment of CO during resuscitation from distributive hypotension, possibly offering a venous-based approach to clinical estimation of volume responsiveness.
Assuntos
Endotoxemia , Hipotensão , Suínos , Animais , Débito Cardíaco/fisiologia , Hemodinâmica , Hipotensão/etiologia , Hipotensão/terapia , Ressuscitação/métodosRESUMO
There are minimal data on the use of venoarterial extracorporeal membrane life support (VA-ECLS) in adult congenital heart disease (ACHD) patients presenting with cardiogenic shock (CS). This study sought to describe the population of ACHD patients with CS who received VA-ECLS in the Extracorporeal Life Support Organization (ELSO) Registry. This was a retrospective analysis of adult patients with diagnoses of ACHD and CS in ELSO from 2009-2021. Anatomic complexity was categorized using the American College of Cardiology/American Heart Association 2018 guidelines. We described patient characteristics, complications, and outcomes, as well as trends in mortality and VA-ECLS utilization. Of 528 patients who met inclusion criteria, there were 32 patients with high-complexity anatomy, 196 with moderate-complexity anatomy, and 300 with low-complexity anatomy. The median age was 59.6 years (interquartile range, 45.8-68.2). The number of VA-ECLS implants increased from five implants in 2010 to 81 implants in 2021. Overall mortality was 58.3% and decreased year-by-year (ß= -2.03 [95% confidence interval, -3.36 to -0.70], p = 0.007). Six patients (1.1%) were bridged to heart transplantation and 21 (4.0%) to durable ventricular assist device. Complications included cardiac arrhythmia/tamponade (21.6%), surgical site bleeding (17.6%), cannula site bleeding (11.4%), limb ischemia (7.4%), and stroke (8.7%). Utilization of VA-ECLS for CS in ACHD patients has increased over time with a trend toward improvement in survival to discharge.
Assuntos
Oxigenação por Membrana Extracorpórea , Cardiopatias Congênitas , Humanos , Adulto , Pessoa de Meia-Idade , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia , Sistema de RegistrosRESUMO
The peripheral venous system serves as a volume reservoir due to its high compliance and can yield information on intravascular volume status. Peripheral venous waveforms can be captured by direct transduction through a peripheral catheter, non-invasive piezoelectric transduction, or gleaned from other waveforms such as the plethysmograph. Older analysis techniques relied upon pressure waveforms such as peripheral venous pressure and central venous pressure as a means of evaluating fluid responsiveness. Newer peripheral venous waveform analysis techniques exist in both the time and frequency domains, and have been applied to various clinical scenarios including hypovolemia (i.e. hemorrhage, dehydration) and volume overload.
RESUMO
OBJECTIVES: Non-invasive venous waveform analysis (NIVA) is a recently described, novel technique to assess intravascular volume status. Waveforms are captured with a piezoelectric sensor; analysis in the frequency domain allows for calculation of a "NIVA value" that represents volume status. The aim of this report was to determine the effects of vasoactive agents on the venous waveform and calculated NIVA values. DESIGN: Porcine experimental model. SETTING: Operating theatre. PARTICIPANTS: A piezoelectric sensor was secured over the surgically exposed saphenous vein in eight anesthetized pigs. MAIN OUTCOME MEASURES: NIVA value, pulmonary capillary wedge pressure (PCWP), and mean arterial pressure prior to and post intravenous administration of 150-180 µg of phenylephrine or 100 µg of sodium nitroprusside. RESULTS: Phenylephrine led to a decrease in NIVA value (mean 9.2 vs. 4.6, p < 0.05), while sodium nitroprusside led to an increase in NIVA value (mean 9.5 vs. 11.9, p < 0.05). Mean arterial pressure increased after phenylephrine (p < 0.05) and decreased after sodium nitroprusside (p < 0.05). PCWP did not change significantly after phenylephrine (p = 0.25) or sodium nitroprusside (p = 0.06). CONCLUSIONS: Vasoactive agents lead to changes in non-invasively obtained venous waveforms in euvolemic pigs, highlighting a potential limitation in the ability to NIVA to estimate static volume in this setting. Further studies are indicated to understand the effects of vasoactive agents in the setting of hypovolemia and hypervolemia.