RESUMO
BACKGROUND: Despite many studies evaluating lung ultrasound (LUS) for COVID-19 prognostication, the generalizability and utility across clinical settings is uncertain. METHODS: Adults (≥18 years of age) with COVID-19 were enrolled at two military hospitals, an emergency department, home visits, and a homeless shelter in the United States, and in a referral hospital in Uganda. Participants had a 12-zone LUS scan performed at time of enrollment and clips were read off-site. The primary outcome was progression to higher level of care after the ultrasound scan. We calculated the cross-validated area under the curve for the validation cohort for individual LUS features. RESULTS: We enrolled 191 participants with COVID-19 were enrolled (57.9% female, median age 45.0 years, interquartile range [IQR]: 31.5, 58.0). Nine participants clinically deteriorated. The top predictors of worsening disease in the validation cohort measured by cross-validated area under the curve (cvAUC) were B-lines (0.88, 95% confidence interval [CI]: 0.87, 0.90), discrete B-lines (0.87, 95% CI: 0.85, 0.88), oxygen saturation (0.82, 95%: CI:0.81, 0.84), and A-lines (0.80, 95% CI: 0.78, 0.81). CONCLUSIONS: In an international multisite POCUS cohort, LUS parameters had high discriminative accuracy. Ultrasound can be applied towards triage across a wide breadth of care settings during a pandemic.
RESUMO
BACKGROUND: Although microscopy is a standard diagnostic tool for malaria and the gold standard, it is infrequently used because of unavailability of laboratory facilities and the absence of skilled readers in poor resource settings. Malaria rapid diagnostic tests (RDT) are currently used instead of or as an adjunct to microscopy. However, at very low parasitaemia (usually < 100 asexual parasites/µl), the test line on malaria rapid diagnostic tests can be faint and consequently hard to visualize and this may potentially affect the interpretation of the test results. Fio Corporation (Canada), developed an automated RDT reader named Deki Reader™ for automatic analysis and interpretation of rapid diagnostic tests. This study aimed to compare visual assessment and automated Deki Reader evaluations to interpret malaria rapid diagnostic tests against microscopy. Unlike in the previous studies where expert laboratory technicians interpreted the test results visually and operated the device, in this study low cadre health care workers who have not attended any formal professional training in laboratory sciences were employed. METHODS: Finger prick blood from 1293 outpatients with fever was tested for malaria using RDT and Giemsa-stained microscopy for thick and thin blood smears. Blood samples for RDTs were processed according to manufacturers' instructions automated in the Deki Reader. Results of malaria diagnoses were compared between visual and the automated devise reading of RDT and microscopy. RESULTS: The sensitivity of malaria rapid diagnostic test results interpreted by the Deki Reader was 94.1% and that of visual interpretation was 93.9%. The specificity of malaria rapid diagnostic test results was 71.8% and that of human interpretation was 72.0%. The positive predictive value of malaria RDT results by the Deki Reader and visual interpretation was 75.8 and 75.4%, respectively, while the negative predictive values were 92.8 and 92.4%, respectively. The accuracy of RDT as interpreted by DR and visually was 82.6 and 82.1%, respectively. CONCLUSION: There was no significant difference in performance of RDTs interpreted by either automated DR or visually by unskilled health workers. However, despite the similarities in performance parameters, the device has proven useful because it provides stepwise guidance on processing RDT, data transfer and reporting.
Assuntos
Testes Diagnósticos de Rotina/métodos , Malária/diagnóstico , Microscopia/métodos , Pacientes Ambulatoriais/estatística & dados numéricos , Parasitemia/diagnóstico , Adolescente , Adulto , Feminino , Instalações de Saúde , Humanos , Masculino , Instalações Militares , Sensibilidade e Especificidade , Tanzânia , Adulto JovemRESUMO
BACKGROUND: Malaria continues to be a major burden in the endemic regions of Kenya. Health outcomes associated with case management are dependent on the use of appropriate diagnostic methods. Rapid diagnostic tests (RDTs) have provided an important tool to help implement the WHO recommended parasite-based diagnosis in regions where expert microscopy is not available. One of the questions that must be answered when implementing RDTs is whether these tests are useful in a specific endemic region, as well as the most appropriate RDT to use. Data on the sensitivity and specificity of RDT test kits is important information to help guide test selection by national malaria control programmes. METHODS: This study evaluated the diagnostic performance of RDTs including First Response (FR), CareStart (CS), SD Bioline (SD), and Binax Now (BN). The performance of these malaria kits was compared to microscopy, the gold standard, for the detection of malaria parasites. The malaria RDTs were also compared to PCR which is a more sensitive reference test. Five-hundred participants were included in the study through community screening (50 %) and testing suspected malaria cases referred from health facilities. RESULTS: Of the 500 participants recruited, 33 % were malaria positive by microscopy while 51.2 % were positive by PCR. Compared to microscopy, the sensitivity of eight RDTs to detect malaria parasites was 90.3-94.8 %, the specificity was 73.3-79.3 %, the positive predictive value was 62.2-68.8 %, and the negative predictive value was 94.3-96.8 %. Compared to PCR, the sensitivity of the RDTs to detect malaria parasites was 71.1-75.4 %, the specificity was 80.3-84.4 %, the positive predictive value was 80.3-83.3 %, and the negative predictive value was 73.7-76.1 %. The RDTs had a moderate measure of agreement with both microscopy (>80.1 %) and PCR (>77.6 %) with a κ > 0.6. CONCLUSION: The performance of the evaluated RDTs using field samples was moderate; hence they can significantly improve the quality of malaria case management in endemic regions in Kenya by ensuring appropriate treatment of malaria positive individuals and avoiding indiscriminate use of anti-malarial drugs for parasite negative patients.
Assuntos
Testes Diagnósticos de Rotina/métodos , Malária/diagnóstico , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Imunoensaio , Lactente , Quênia , Masculino , Microscopia , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade , Adulto JovemRESUMO
The safety and immunogenicity of the two-dose Ebola vaccine regimen MVA-BN-Filo, Ad26.ZEBOV, 14 days apart, was evaluated in people without HIV (PWOH) and living with HIV (PLWH). In this observer-blind, placebo-controlled, phase 2 trial, healthy adults were randomized (4:1) to receive MVA-BN-Filo (dose 1) and Ad26.ZEBOV (dose 2), or two doses of saline/placebo, administered intramuscularly 14 days apart. The primary endpoints were safety (adverse events (AEs)) and immunogenicity (Ebola virus (EBOV) glycoprotein-specific binding antibody responses). Among 75 participants (n = 50 PWOH; n = 25 PLWH), 37% were female, the mean age was 44 years, and 56% were Black/African American. AEs were generally mild/moderate, with no vaccine-related serious AEs. At 21 days post-dose 2, EBOV glycoprotein-specific binding antibody responder rates were 100% among PWOH and 95% among PLWH; geometric mean antibody concentrations were 6286 EU/mL (n = 36) and 2005 EU/mL (n = 19), respectively. A total of 45 neutralizing and other functional antibody responses were frequently observed. Ebola-specific CD4+ and CD8+ T-cell responses were polyfunctional and durable to at least 12 months post-dose 2. The regimen was well tolerated and generated robust, durable immune responses in PWOH and PLWH. Findings support continued evaluation of accelerated vaccine schedules for rapid deployment in populations at immediate risk. Trial registration: NCT02598388 (submitted 14 November 2015).
RESUMO
The clinical utility of point-of-care lung ultrasound (LUS) among hospitalized patients with COVID-19 is unclear. DESIGN: Prospective cohort study. SETTING: A large tertiary care center in Maryland, between April 2020 and September 2021. PATIENTS: Hospitalized adults (≥ 18 yr old) with positive severe acute respiratory syndrome coronavirus 2 reverse transcriptase-polymerase chain reaction results. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: All patients were scanned using a standardized protocol including 12 lung zones and followed to determine clinical outcomes until hospital discharge and vital status at 28 days. Ultrasounds were independently reviewed for lung and pleural line artifacts and abnormalities, and the mean LUS Score (mLUSS) (ranging from 0 to 3) across lung zones was determined. The primary outcome was time to ICU-level care, defined as high-flow oxygen, noninvasive, or invasive mechanical ventilation, within 28 days of the initial ultrasound. Cox proportional hazards regression models adjusted for age and sex were fit for mLUSS and each ultrasound covariate. A total of 264 participants were enrolled in the study; the median age was 61 years and 114 participants (43.2%) were female. The median mLUSS was 1.0 (interquartile range, 0.5-1.3). Following enrollment, 27 participants (10.0%) went on to require ICU-level care, and 14 (5.3%) subsequently died by 28 days. Each increase in mLUSS at enrollment was associated with disease progression to ICU-level care (adjusted hazard ratio [aHR], 3.61; 95% CI, 1.27-10.2) and 28-day mortality (aHR, 3.10; 95% CI, 1.29-7.50). Pleural line abnormalities were independently associated with disease progression to death (aHR, 20.93; CI, 3.33-131.30). CONCLUSIONS: Participants with a mLUSS greater than or equal to 1 or pleural line changes on LUS had an increased likelihood of subsequent requirement of high-flow oxygen or greater. LUS is a promising tool for assessing risk of COVID-19 progression at the bedside.
RESUMO
Eleven new tetraoxanes possessing cholic acid-derived carrier and isopropylidene moiety were synthesized and were tested in vitro and in vivo. In vitro screening revealed that nine of them were more potent against CQ-resistant W2 than CQ-susceptible D6 strain and that two of them were equally or more potent than artemisinin and mefloquine against multi-drug resistant TM91C235 strain. Amine 8 cured all mice at the dose of 160mg/kg/day, while the anilide 9 exhibited MCDAssuntos
Antimaláricos/síntese química
, Tetraoxanos/síntese química
, Tetraoxanos/farmacologia
, Acetona
, Animais
, Artemisininas
, Avaliação Pré-Clínica de Medicamentos
, Resistência a Múltiplos Medicamentos
, Mefloquina
, Camundongos
, Plasmodium falciparum/efeitos dos fármacos
RESUMO
INTRODUCTION: Internal and external quality control (QC) of rapid diagnostic tests (RDTs) is important to increase reliability of RDTs currently used to diagnose malaria. However, cross-checking of used RDTs as part of quality assurance can rarely be done by off-site personnel because there is no guarantee of retaining visible test lines after manufacturers' recommended reading time. Therefore, this study examined the potential of using Fionet™ technology for remote RDT quality monitoring at seven clinics, identifying reasons for making RDT processing and interpretation errors, and taking corrective actions for improvement of diagnosis and consequently improved management of febrile patients. METHODS: The study was conducted at seven military health facilities in Mainland Tanzania and utilized RDTs capable of detecting Plasmodium falciparum specific Histidine-rich protein 2 (Pf-HRP2) and the genus specific Plasmodium lactate dehydrogenase (pLDH) for other species of plasmodium (P. vivax, P. malariae or P. ovale; pan-pLDH). Patients' data and images of processed RDTs from seven clinics were uploaded on a Fionet web portal and reviewed regularly to monitor preparation procedures and visual interpretation of test results compared to automated analysis using the Deki reader of RDT. Problems detected were rapidly communicated to remote laboratory personnel at the clinic for corrective action and follow-up of patients who were falsely diagnosed as negative and missed treatment. Factors contributing to making errors in visual interpretation of RDT results were analyzed during visits to the health facilities. RESULTS: A total of 1,367 (1.6%) out of 83,294 RDT test images uploaded to the Fionet portal had discordant test results of which 822 (60.1%) and 545 (39.9%) were falsely reported as negative and positive, respectively. False negative and false positive test results were common for a single test line in 515 (62.7%) and 741 (54.2%) tests, respectively. Out of 1,367 RDT images assessed, 98 (7.2%) had quality problems related to preparation procedures of which 95(96.9%) errors were due to putting too much blood on the sample well or insufficient buffer in the respective wells. The reasons for discrepant results included, false reporting of none existent lines in 526 (38.5%) tests, missing a faint positive line in 493 (36.1%), missing a strong positive line in 248(18.1%) and errors caused by poorly processed RDTs in 96 (7.2%) tests. Among the false negative tests (n = 822), 669 (48.9%) patients were eligible for follow-up and only 339 (48.5%) were reached and 291 (85.8%) received appropriate anti-malaria therapy. CONCLUSION: Fionet technology enabled remote monitoring of RDT quality issues, identifying reasons contributing to laboratory personnel making errors and provided a rapid method to implement corrective actions at remote sites to improve malaria diagnosis and consequently improved health care management of febrile patients infected with malaria.
Assuntos
Testes Diagnósticos de Rotina , Pessoal de Saúde , Malária/diagnóstico , Análise e Desempenho de Tarefas , Adolescente , Adulto , Antígenos de Protozoários/análise , Criança , Pré-Escolar , Erros de Diagnóstico , Testes Diagnósticos de Rotina/normas , Feminino , Instalações de Saúde , Humanos , Lactente , Recém-Nascido , L-Lactato Desidrogenase/análise , L-Lactato Desidrogenase/normas , Masculino , Plasmodium falciparum/metabolismo , Proteínas de Protozoários/análise , Proteínas de Protozoários/normas , Controle de Qualidade , Tanzânia , Adulto JovemRESUMO
The synthesis of the chimeric molecules consisting of two pharmacophores, tetraoxane and 7-chloro-4-aminoquinoline, is reported. The tetraoxanes 2, 4, and 8 show relatively potent in vitro antimalarial activities, with IC90 values for the Plasmodium falciparum strain W2 of 2.26, 12.44, and 10.74 nM, respectively. In addition, two compounds, 2 and 4, cured mice in a modified Thompson test for antimalarial blood stage activity, with a minimum curative dose of 80 mg/kg, a minimum active dose of 20 mg/kg/day, and a maximum tolerated dose of >960 mg/kg.
Assuntos
Aminoquinolinas/química , Antimaláricos/síntese química , Antimaláricos/farmacologia , Malária/tratamento farmacológico , Plasmodium falciparum/efeitos dos fármacos , Tetraoxanos/química , Animais , Antimaláricos/química , Sítios de Ligação , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Malária/sangue , Malária/parasitologia , Dose Máxima Tolerável , Camundongos , Estrutura Molecular , Testes de Sensibilidade Parasitária , Estereoisomerismo , Relação Estrutura-AtividadeRESUMO
Pyrroloquinazolinediamine (PQD) derivatives such as tetra-acetamide PQD (PQD-A4) and bis-ethylcarbamyl PQD (PQD-BE) were much safer (with therapeutic indices of 80 and 32, respectively) than their parent compound, PQD (therapeutic index, 10). Further evaluation of PQD-A4 and PQD-BE in single and multiple pharmacokinetic (PK) studies as well as corresponding toxicity studies was conducted with rats. PQD-A4 could be converted to two intermediate metabolites (monoacetamide PQD and bisacetamide PQD) first and then to the final metabolite, PQD, while PQD-BE was directly hydrolyzed to PQD without precursor and intermediate metabolites. Maximum tolerant doses showed that PQD-A4 and PQD-BE have only 1/12 and 1/6, respectively, of the toxicity of PQD after a single oral dose. Compared to the area under the concentration-time curve for PQD alone (2,965 ng.h/ml), values measured in animals treated with PQD-A4 and PQD-BE were one-third (1,047 ng.h/ml) and one-half (1,381 ng.h/ml) as high, respectively, after an equimolar dosage, suggesting that PQD was the only agent to induce the toxicity. Similar results were also shown in multiple treatments; PQD-A4 and PQD-BE generated two-fifths and three-fifths, respectively, of PQD concentrations, with 8.8-fold and 3.8-fold safety margins, respectively, over the parent drug. PK data indicated that the bioavailability of oral PQD-A4 was greatly limited at high dose levels, that PQD-A4 was slowly converted to PQD via a sequential three-step process of conversion, and that PQD-A4 was significantly less toxic than the one-step hydrolysis drug, PQD-BE. It was concluded that the slow and smaller release of PQD was the main reason for the reduction in toxicity and that the active intermediate metabolites can still maintain antimalarial potency. Therefore, the candidate with multiple-step hydrolysis of PQD could be developed as a safer potential agent for malaria treatment.