1.
Anal Chem ; 93(49): 16664-16672, 2021 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-34865468

RESUMO

Peptide bioreporters were developed to perform multiplexed measurements of the activation of epidermal growth factor receptor kinase (EGFR), Akt kinase (Akt/protein kinase B), and proteases/peptidases in single cells. The performance characteristics of the three reporters were assessed by measuring the reporter's proteolytic stability, kinetic constants for EGFR and Akt, and dephosphorylation rate. The reporter displaying optimal performance was composed of 6-carboxyfluorescein (6-FAM) on the peptide N-terminus, an Akt substrate sequence employing a threonine phosphorylation site for Akt, followed by a tri-D arginine linker, and finally an EGFR substrate sequence bearing a phosphatase-resistant 7-(S)-hydroxy-1,2,3,4-tetrahydroisoquinoline-3-carboxylic acid (L-htc) residue as the EGFR phosphorylation site. Importantly, use of a single electrophoretic condition separated the mono- and diphosphorylated products as well as proteolytic forms permitting the quantitation of multiple enzyme activities simultaneously using a single reporter. Because the Akt and EGFR substrates were linked, a known ratio (EGFR/Akt) of the reporter was loaded into cells. A photoactivatable version of the reporter was synthesized by adding two 4,5-dimethoxy-2-nitrobenzyl (DMNB) moieties to mask the EGFR and Akt phosphorylation sites. The DMNB moieties were readily photocleaved following exposure to 360 nm light, unmasking the phosphorylation sites on the reporter. The new photoactivatable reporter permitted multiplexed measurements of kinase signaling and proteolytic degradation in single cells in a temporally controlled manner. This work will facilitate the development of a new generation of multiplexed activity-based reporters capable of light-initiated measurement of enzymatic activity in single cells.


Assuntos
Receptores ErbB , Peptídeo Hidrolases/análise , Peptídeos , Proteínas Proto-Oncogênicas c-akt/análise , Receptores ErbB/análise , Cinética , Proteólise , Análise de Célula Única
2.
Trends Analyt Chem ; 1222020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32153309

RESUMO

Analytical assays performed within clinical laboratories influence roughly 70% of all medical decisions by facilitating disease detection, diagnosis, and management. Both in clinical and academic research laboratories, single-cell assays permit measurement of cell diversity and identification of rare cells, both of which are important in the understanding of disease pathogenesis. For clinically utility, the single-cell assays must be compatible with the clinical workflow steps of sample collection, sample transportation, pre-analysis processing, and single-cell assay; therefore, it is paramount to preserve cells in a state that resembles that in vivo rather than measuring signaling behaviors initiated in response to stressors such as sample collection and processing. To address these challenges, novel cell fixation (and more broadly, cell preservation) techniques incorporate programmable fixation times, reversible bond formation and cleavage, chemoselective reactions, and improved analyte recovery. These technologies will further the development of individualized, precision therapies for patients to yield improved clinical outcomes.

3.
Methods Enzymol ; 628: 191-221, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31668230

RESUMO

Single-cell analysis of cellular contents by highly sensitive analytical instruments is known as chemical cytometry. A chemical cytometer typically samples one cell at a time, quantifies the cellular contents of interest, and then processes and reports that data. Automation adds the potential to perform this entire sequence of events with minimal intervention, increasing throughput and repeatability. In this chapter, we discuss the design considerations for an automated capillary electrophoresis-based instrument for assay of enzymatic activity within single cells. We describe the key requirements of the microscope base and capillary electrophoresis platforms. We also provide detailed protocols and schematic designs of our cell isolation, lysis, sampling, and detection strategies. Additionally, we describe our signal processing and instrument automation workflows. The described automated system has demonstrated single-cell throughput at rates above 100cells/h and analyte limits of detection as low as 10-20mol.


Assuntos
Eletroforese Capilar/instrumentação , Análise de Célula Única/instrumentação , Animais , Citofotometria/instrumentação , Citofotometria/métodos , Eletroforese Capilar/métodos , Desenho de Equipamento , Humanos , Microscopia/instrumentação , Microscopia/métodos , Análise de Célula Única/métodos , Software
4.
ACS Chem Biol ; 13(7): 1741-1751, 2018 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-29376326

RESUMO

The bulk cell population response to a stimulus, be it a growth factor or a cytotoxic agent, neglects the cell-to-cell variability that can serve as a friend or as a foe in human biology. Biochemical variations among closely related cells furnish the basis for the adaptability of the immune system but also act as the root cause of resistance to chemotherapy by tumors. Consequently, the ability to probe for the presence of key biochemical variables at the single-cell level is now recognized to be of significant biological and biomedical impact. Chemical cytometry has emerged as an ultrasensitive single-cell platform with the flexibility to measure an array of cellular components, ranging from metabolite concentrations to enzyme activities. We briefly review the various chemical cytometry strategies, including recent advances in reporter design, probe and metabolite separation, and detection instrumentation. We also describe strategies for improving intracellular delivery, biochemical specificity, metabolic stability, and detection sensitivity of probes. Recent applications of these strategies to small molecules, lipids, proteins, and other analytes are discussed. Finally, we assess the current scope and limitations of chemical cytometry and discuss areas for future development to meet the needs of single-cell research.


Assuntos
Corantes Fluorescentes/química , Análise de Célula Única/métodos , Animais , Linhagem Celular Tumoral , Desenho de Fármacos , Eletroforese Capilar/métodos , Humanos