Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
N Engl J Med ; 382(2): 130-139, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31733182

RESUMO

BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).


Assuntos
Valva Aórtica/fisiopatologia , Aspirina/farmacologia , Clopidogrel/farmacologia , Inibidores do Fator Xa/farmacologia , Próteses Valvulares Cardíacas , Inibidores da Agregação Plaquetária/farmacologia , Rivaroxabana/farmacologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/efeitos dos fármacos , Valva Aórtica/patologia , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Clopidogrel/uso terapêutico , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Feminino , Tomografia Computadorizada Quadridimensional , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/efeitos adversos , Rivaroxabana/uso terapêutico , Tromboembolia/etiologia , Tromboembolia/mortalidade
2.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36942949

RESUMO

AIMS: In bradycardia patients treated with dual-chamber pacing, we aimed to evaluate whether pacing with atrioventricular (AV) delay management [AV hysteresis (AVH)], compared with standard pacing with fixed AV delays, reduces unnecessary ventricular pacing percentage (VPP) and is associated with better clinical outcomes. Main study endpoints were the incidence of heart failure hospitalizations (HFH), persistent atrial fibrillation (AF), and cardiac death. METHODS AND RESULTS: Data from two identical prospective observational studies, BRADYCARE I in the USA and BRADYCARE II in Europe, Africa, and Asia, were pooled. Overall, 2592 patients (75 ± 10 years, 45.1% female, 50% with AVH) had complete clinical and device data at 1-year follow-up and were analysed. Primary pacing indication was sinus node disease (SND) in 1177 (45.4%), AV block (AVB) in 974 (37.6%), and other indications in 441 (17.0%) patients. Pacing with AVH, compared with standard pacing, was associated with a lower 1-year incidence of HFH [1.3% vs. 3.1%, relative risk reduction (RRR) 57.5%, P = 0.002] and of persistent AF (5.3% vs. 7.7%, RRR = 31.1%, P = 0.028). Cardiac mortality was not different between groups (1.0% vs. 1.4%, RRR = 27.8%, P = 0.366). Pacing with AVH, compared with standard pacing, was associated with a lower (P < 0.001) median VPP in all patients (7% vs. 75%), in SND (3% vs. 44%), in AVB (25% vs. 98%), and in patients with other pacing indications (3% vs. 47%). CONCLUSION: Cardiac pacing with AV delay management via AVH is associated with reduced 1-year incidence of HFH and persistent AF, most likely due to a reduction in VPP compared to standard pacing.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Incidência , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Síndrome do Nó Sinusal/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/prevenção & controle , Hospitalização
3.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37038759

RESUMO

AIMS: To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. METHODS AND RESULTS: In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. CONCLUSION: A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Anticoagulantes
4.
Europace ; 23(5): 740-747, 2021 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-33313789

RESUMO

AIMS: Totally leadless cardiac resynchronization therapy (CRT) can be delivered with a combination of Micra and WiSE-CRT systems. We describe the technical feasibility and first insights into the safety and efficacy of this combination in European experience. METHODS AND RESULTS: Patients enrolled had indication for both Micra and WiSE-CRT systems because of heart failure related to high burden of pacing by a Micra necessitating system upgrade or inability to implant a conventional CRT system because of infectious or anatomical conditions. The endpoints of the study were technical success of WiSE-CRT implantation with right ventricle-synchonized CRT delivery, acute QRS duration reduction, and freedom from procedure-related major adverse events. All eight WiSE-CRT devices were able to detect the Micra pacing output and to be trained to deliver synchronous LV endocardial pacing. Acute QRS reduction following WiSE-CRT implantation was observed in all eight patients (mean QRS 204.38 ± 30.26 vs. 137.5 ± 24.75 mS, P = 0.012). Seven patients reached 6 months of follow-up. At 6 months after WiSE-CRT implantation, there was a significant increase in LV ejection fraction (28.43 ± 8.01% vs. 39.71 ± 11.89%; P = 0.018) but no evidence of LV reverse remodelling or improvement in New York Heart Association class. CONCLUSION: The Micra and the WiSE-CRT systems can successfully operate together to deliver total leadless CRT to a patient. Moreover, the WiSE-CRT system provides the only means to upgrade the large population of Micra patients to CRT capability without replacing the Micra. The range of application of this combination could broaden in the future with the upcoming developments of leadless cardiac pacing.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento
5.
Europace ; 23(10): 1577-1585, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34322707

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) upgrades may be less likely to improve following intervention. Leadless left ventricular (LV) endocardial pacing has been used for patients with previously failed CRT or high-risk upgrades. We compared procedural and long-term outcomes in patients undergoing coronary sinus (CS) CRT upgrades with high-risk and previously failed CRT upgrades undergoing LV endocardial upgrades. METHOD AND RESULTS: Prospective consecutive CS upgrades between 2015 and 2019 were compared with those undergoing WiSE-CRT implantation. Cardiac resynchronization therapy response at 6 months was defined as improvement in clinical composite score (CCS) and a reduction in LV end-systolic volume (LVESV) ≥15%. A total of 225 patients were analysed; 121 CS and 104 endocardial upgrades. Patients receiving WiSE-CRT tended to have more comorbidities and were more likely to have previous cardiac surgery (30.9% vs. 16.5%; P = 0.012), hypertension (59.2% vs. 34.7%; P < 0.001), chronic obstructive airways disease (19.4% vs. 9.9%; P = 0.046), and chronic kidney disease (46.4% vs. 21.5%; P < 0.01) but similar LV ejection fraction (30.0 ± 8.3% vs. 29.5 ± 8.6%; P = 0.678). WiSE-CRT upgrades were successful in 97.1% with procedure-related mortality in 1.9%. Coronary sinus upgrades were successful in 97.5% of cases with a 2.5% rate of CS dissection and 5.6% lead malfunction/displacement. At 6 months, 91 WiSE-CRT upgrades and 107 CS upgrades had similar improvements in CCS (76.3% vs. 68.5%; P = 0.210) and reduction in LVESV ≥15% (54.2% vs. 56.3%; P = 0.835). CONCLUSION: Despite prior failed upgrades and high-risk patients with more comorbidities, WiSE-CRT upgrades had high rates of procedural success and similar improvements in CCS and LV remodelling with CS upgrades.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Insuficiência Cardíaca , Seio Coronário/diagnóstico por imagem , Endocárdio , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
6.
Curr Cardiol Rep ; 23(10): 139, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410518

RESUMO

PURPOSE OF REVIEW: New transcatheter techniques to perform tricuspid annuloplasty are evolving and are introduced into the clinical routine. Yet, clinical experience is limited. RECENT FINDINGS: Currently, 3 different techniques for tricuspid annuloplasty have been used in larger clinical cohorts. They can be divided into direct annuloplasty techniques and suture plication techniques. The largest clinical evidence is related to direct annuloplasty techniques. It has been shown that annular dimensions can be effectively reduced. This translates into an improvement of the degree of tricuspid regurgitation and improvement of clinical symptoms. Due to the newness of this type of therapy, long-term data is limited, but for one of the described techniques, published data show that the positive effects persist over a 2-year period. Transcatheter approaches are safe and are able to treat tricuspid regurgitation effectively. There are still differences in the efficacy of the different techniques. Clinical experience varies among the different approaches.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
7.
Eur Heart J ; 40(5): 441-451, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30357365

RESUMO

Aims: We sought to evaluate the outcomes of transcatheter mitral valve replacement (TMVR) for patients with degenerated bioprostheses [valve-in-valve (ViV)], failed annuloplasty rings [valve-in-ring (ViR)], and severe mitral annular calcification [valve-in-mitral annular calcification (ViMAC)]. Methods and results: From the TMVR multicentre registry, procedural and clinical outcomes of ViV, ViR, and ViMAC were compared according to Mitral Valve Academic Research Consortium (MVARC) criteria. A total of 521 patients with mean Society of Thoracic Surgeons score of 9.0 ± 7.0% underwent TMVR (322 patients with ViV, 141 with ViR, and 58 with ViMAC). Trans-septal access and the Sapien valves were used in 39.5% and 90.0%, respectively. Overall technical success was excellent at 87.1%. However, left ventricular outflow tract obstruction occurred more frequently after ViMAC compared with ViR and ViV (39.7% vs. 5.0% vs. 2.2%; P < 0.001), whereas second valve implantation was more frequent in ViR compared with ViMAC and ViV (12.1% vs. 5.2% vs. 2.5%; P < 0.001). Accordingly, technical success rate was higher after ViV compared with ViR and ViMAC (94.4% vs. 80.9% vs. 62.1%; P < 0.001). Compared with ViMAC and ViV groups, ViR group had more frequent post-procedural mitral regurgitation ≥moderate (18.4% vs. 13.8% vs. 5.6%; P < 0.001) and subsequent paravalvular leak closure (7.8% vs. 0.0% vs. 2.2%; P = 0.006). All-cause mortality was higher after ViMAC compared with ViR and ViV at 30 days (34.5% vs. 9.9% vs. 6.2%; log-rank P < 0.001) and 1 year (62.8% vs. 30.6% vs. 14.0%; log-rank P < 0.001). On multivariable analysis, patients with failed annuloplasty rings and severe MAC were at increased risk of mortality after TMVR [ViR vs. ViV, hazard ratio (HR) 1.99, 95% confidence interval (CI) 1.27-3.12; P = 0.003; ViMAC vs. ViV, HR 5.29, 95% CI 3.29-8.51; P < 0.001]. Conclusion: The TMVR provided excellent outcomes for patients with degenerated bioprostheses despite high surgical risk. However, ViR and ViMAC were associated with higher rates of adverse events and mid-term mortality compared with ViV.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Valva Mitral/cirurgia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Calcinose/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Anuloplastia da Valva Mitral/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
8.
Eur Heart J ; 40(38): 3156-3165, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31230081

RESUMO

AIMS: Peri-procedural transcatheter valve embolization and migration (TVEM) is a rare but potentially devastating complication of transcatheter aortic valve implantation (TAVI). We sought to assess the incidence, causes, and outcome of TVEM in a large multicentre cohort. METHODS AND RESULTS: We recorded cases of peri-procedural TVEM in patients undergoing TAVI between January 2010 and December 2017 from 26 international sites. Peri-procedural TVEM occurred in 273/29 636 (0.92%) TAVI cases (age 80.8 ± 7.3 years; 53.8% female), of which 217 were to the ascending aorta and 56 to the left ventricle. The use of self-expanding or first-generation prostheses and presence of a bicuspid aortic valve were independent predictors of TVEM. Bail-out measures included repositioning attempts using snares or miscellaneous tools (41.0%), multiple valve implantations (83.2%), and conversion to surgery (19.0%). Using 1:4-propensity matching, we identified a cohort of 235 patients with TVEM (TVEMPS) and 932 patients without TVEM (non-TVEMPS). In the matched cohort, all-cause mortality was higher in TVEMPS than in non-TVEMPS at 30 days (18.6% vs. 4.9%; P < 0.001) and after 1 year (30.5% vs. 16.6%; P < 0.001). Major stroke was more frequent in TVEMPS at 30 days (10.6% vs. 2.8%; P < 0.001), but not at 1 year (4.6% vs. 1.9%; P = 0.17). The need for emergent cardiopulmonary support, major stroke at 30 days, and acute kidney injury Stages 2 and 3 increased the risk of 1-year mortality, whereas a better renal function at baseline was protective. CONCLUSION: Transcatheter valve embolization and migration occurred in approximately 1% and was associated with increased morbidity and mortality.


Assuntos
Embolia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Embolia/epidemiologia , Embolia/etiologia , Embolia/mortalidade , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Falha de Prótese/efeitos adversos , Falha de Prótese/etiologia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
9.
Stroke ; 50(11): 3051-3056, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31558143

RESUMO

Background and Purpose- Heart failure (HF) in patients with acute ischemic stroke constitutes the source of various detrimental pathophysiologic mechanisms including prothrombotic and proinflammatory states, worsening of cerebral tissue oxygenation, and hemodynamic impairment. In addition, HF might affect the safety and efficacy of the acute recanalization stroke therapies. Methods- Patients treated with intravenous recombinant tissue-type plasminogen activator or mechanical recanalization at a universitary stroke center were included into a prospective registry. Patients received cardiological evaluation, including echocardiography, during acute care. Functional outcome was assessed after 90 days by structured telephone interviews. Safety and efficacy of intravenous thrombolysis and mechanical thrombectomy were investigated among patients with HF and compared with patients with normal cardiac function after propensity score matching. Results- One thousand two hundred nine patients were included. HF was present in 378 patients (31%) and an independent predictor of unfavorable functional outcome. Recanalization rates were equal among patients with HF after intravenous thrombolysis and after mechanical recanalization or combined treatment. The rate of secondary intracranial hemorrhage was not different (7% versus 8%; P=0.909 after thrombolysis and 15% versus 20%, P=0.364 after mechanical recanalization or combined therapy). Early mortality within 48 hours after admission was equal (<1.5% in both groups). Conclusions- In this real-world cohort of patients with stroke, HF was an independent predictor of unfavorable functional long-term outcome, while the safety and efficacy of intravenous thrombolysis and mechanical recanalization appeared unaffected.


Assuntos
Isquemia Encefálica , Revascularização Cerebral , Insuficiência Cardíaca , Hemorragias Intracranianas , Trombólise Mecânica , Sistema de Registros , Acidente Vascular Cerebral , Ativador de Plasminogênio Tecidual , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/complicações , Isquemia Encefálica/mortalidade , Isquemia Encefálica/terapia , Intervalo Livre de Doença , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Hemorragias Intracranianas/etiologia , Hemorragias Intracranianas/mortalidade , Hemorragias Intracranianas/terapia , Masculino , Estudos Prospectivos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/terapia , Taxa de Sobrevida , Fatores de Tempo , Ativador de Plasminogênio Tecidual/administração & dosagem , Ativador de Plasminogênio Tecidual/efeitos adversos
10.
Eur Radiol ; 26(12): 4497-4504, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26995206

RESUMO

OBJECTIVES: Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. METHODS: Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. RESULTS: Mean patient age was 82 ± 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 ± 60 HU/1.5 at the aortic annulus compared to 289 ± 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 ± 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. CONCLUSION: Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. KEY POINTS: • Reduction of contrast agent volume is crucial in patients with chronic renal failure. • Novel third-generation computed tomography helps to reduce contrast agent volume. • Pre-procedural CT allows comprehensive imaging for procedural success before heart valve implantation. • A low-contrast CT protocol is feasible for pre-procedural TAVI planning.


Assuntos
Estenose da Valva Aórtica/cirurgia , Meios de Contraste/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Estudos de Viabilidade , Feminino , Humanos , Falência Renal Crônica , Masculino , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos
11.
J Stroke Cerebrovasc Dis ; 24(5): 946-51, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25804569

RESUMO

BACKGROUND: Growing evidence suggests that the heart rate (HR) at rest is an independent predictor of cardiovascular mortality. In ischemic stroke, continuous monitoring of HR is the standard of care, but systematic data on its dynamics and prognostic value during the acute phase are limited. METHODS: In this prospective observational study, HR was measured by continuous electrocardiographic monitoring on admission and during the first 72 hours of care among patients who were awake with ischemic stroke and survived until discharge. Functional outcome was assessed after 90 days. RESULTS: Data from 702 consecutive patients were analyzed (median age, 73 years, 54% men). The time course of HR was initially characterized by a rapid decline during the first 12 hours after admission. Among patients who survived until day 90, this was followed by a continuous downward trend in HR, whereas death after discharge was associated with a secondary increase and a reversal point 12 hours after admission. After adjustment for established risk factors, this secondary increase during the acute period was an independent predictor of death (hazard ratio, 3.73; 95% confidence interval, 1.47-9.43; P = .005). CONCLUSIONS: A secondary rise of HR during care for acute ischemic stroke is an early sign of fatality and may represent a surrogate for an unfavorable sympathetic disinhibition. Further research is warranted to clarify the role of targeted HR reduction after ischemic stroke (http://clinicaltrials.gov/, unique identifier NCT01858779).


Assuntos
Isquemia Encefálica/complicações , Frequência Cardíaca/fisiologia , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/etiologia , Idoso , Idoso de 80 Anos ou mais , Temperatura Corporal , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatísticas não Paramétricas , Fatores de Tempo
12.
Int J Med Microbiol ; 304(8): 1050-61, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25130702

RESUMO

Pseudomonas aeruginosa is the leading pathogen of chronic cystic fibrosis (CF) lung infection. Life-long persistence in the inflamed and ever fluctuating CF lungs results in the selection of a variety of changes in P. aeruginosa physiology. Accumulating evidence suggests that especially metabolic changes support the survival and growth of P. aeruginosa within the hypoxic and nutritious CF mucus. To investigate if metabolic adaptations we described for hypermutable P. aeruginosa from late CF lung disease (Hoboth et al., 2009. J. Infect. Dis., pp. 118-130) may represent specific changes in response to the selective conditions within the oxygen-restricted CF mucus, we determined the expression of a set of genes during aerobic and hypoxic growth in LB and the artificial sputum medium ASM. We further focused on the regulation of the two isocitrate dehydrogenases Icd and Idh. Interestingly, both isoenzymes may replace each other under aerobic and hypoxic conditions. The NADPH- and RpoS-dependent Icd seems to be the leading isoenzyme under prolonged oxygen limitation and stationary growth phase. LacZ reporter analysis revealed that oxygen-restriction increased the expression levels of azu, cbb3-1, cbb3-2, ccpR, icd, idh and oprF gene, whereas himD and nuoA are increasingly expressed only during hypoxic growth in ASM. Overexpression of the anaerobic regulator Anr improved the expression of azu, ccpR, cbb3-2 and icd. In summary, expression of azu, cbb3-1, cbb3-2, ccpR, icd, idh, oprF, himD, and nuoA appeared to be beneficial for the growth of P. aeruginosa under hypoxic conditions indicating these genes may represent marker genes for the metabolic adaptation to the CF lung environment.


Assuntos
Adaptação Biológica , Fibrose Cística/complicações , Marcadores Genéticos , Hipóxia/complicações , Redes e Vias Metabólicas/genética , Infecções por Pseudomonas/microbiologia , Pseudomonas aeruginosa/genética , Fibrose Cística/patologia , Expressão Gênica , Humanos , Isocitrato Desidrogenase/genética , Pseudomonas aeruginosa/crescimento & desenvolvimento , Pseudomonas aeruginosa/isolamento & purificação , Pseudomonas aeruginosa/metabolismo , Infecções Respiratórias/microbiologia
13.
Eur Radiol ; 24(8): 1878-88, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24845112

RESUMO

OBJECTIVES: To evaluate a systematic approach for measurement of aortic annulus dimensions by cardiac computed tomography. METHODS: CT data sets of 64 patients were evaluated. An oblique cross-section aligned with the aortic root was created by systematically identifying the caudal insertion points of the three aortic cusps and sequentially aligning them in a double oblique plane. Aortic annulus dimensions, distances of coronary ostia and a suitable fluoroscopic projection angle were independently determined by two observers. RESULTS: Interobserver intraclass correlation coefficients (ICC) for aortic annulus diameters were excellent (ICC 0.89-0.93). Agreement for prosthesis size selection was excellent (ĸ = 0.86 for mean, ĸ = 0.84 for area-derived and ĸ = 0.91 for circumference-derived diameter). Mean distances of the left/right coronary ostium were 13.4 ± 2.4/14.4 ± 2.8 mm for observer 1 and 13.2 ± 2.7/13.5 ± 3.2 mm for observer 2 (p = 0.30 and p = 0.0001, respectively; ICC 0.76/0.77 for left/right coronary artery). A difference of less than 10° for fluoroscopic projection angle was achieved in 84.3% of patients. CONCLUSIONS: A systematic approach to generate a double oblique imaging plane exactly aligned with the aortic annulus demonstrates high interobserver and intraobserver agreements for derived measurements which are not influenced by aortic root calcification. KEY POINTS: • Systematic approach to generate a double oblique imaging plane for TAVI evaluation. • This method is straightforward and software independent. • An approach with high reproducibility, not influenced by aortic root calcification.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Imageamento Tridimensional , Tomografia Computadorizada Multidetectores/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Curva ROC , Reprodutibilidade dos Testes
14.
Struct Heart ; 8(1): 100226, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283573

RESUMO

Background: The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. Methods: This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. Results: We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). Conclusions: The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. ClinicalTrialsgov Identifier: NCT03752866.

15.
JACC Cardiovasc Interv ; 16(16): 1965-1973, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648344

RESUMO

BACKGROUND: Patients with severe aortic regurgitation (AR) are often not considered for surgery because of increased surgical risk. Because of unique anatomical characteristics among patients with AR, interventional treatment options are limited, and implantation results are inconsistent compared with those among patients with aortic stenosis. OBJECTIVES: The authors describe the initial commercial experience of the first Conformité Européenne-marked transfemoral transcatheter aortic valve replacement system (JenaValve Trilogy [JV]) for the treatment of patients with AR. METHODS: This multicenter registry included 58 consecutive patients from 6 centers across Germany. Transcatheter aortic valve replacement was performed with the JV system for isolated severe and symptomatic AR. Patient characteristics, primary implantation outcomes, and valve performance up to 30 days were analyzed using Valve Academic Research Consortium 3 definitions. RESULTS: The mean patient age was 76.5 ± 9 years, with a mean Society of Thoracic Surgeons score of 4.2% ± 4.3%. Device success was achieved in 98% of patients. The mean gradient was 4.3 ± 1.6 mm Hg, and no moderate or severe paravalvular regurgitation occurred. No conversion to open heart surgery or valve embolization was reported. There were no major vascular complications or bleeding events. The rate of new permanent pacemaker implantation was 19.6%. At 30 days, 92% of the patients were in NYHA functional class I or II, and the 30-day mortality rate was 1.7%. CONCLUSIONS: Treatment of patients with severe symptomatic AR using the transfemoral JV system is safe and effective. Given its favorable hemodynamic performance and low complication rates, this system may offer a new treatment option for patients with AR not suitable for surgery.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
16.
J Clin Med ; 11(16)2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-36013084

RESUMO

A total of 1001 subjects (82.0 years, 62.5% female, 63.7% NYHA III/IV at baseline) with severe aortic stenosis at high surgical risk were enrolled in the prospective CONFIDENCE registry and treated with a Portico™ transcatheter heart valve (THV) using either a first-generation delivery system (DS) or the FlexNav™ DS. The objective of this registry is to characterize the procedural safety and device performance of the Portico™ THV at 30 days. The study collected 'standard-of-care' clinical and device performance data, with adverse events adjudicated by an independent clinical event committee according to the Valve Academic Research Consortium-2 criteria. The implantation of a single Portico™ THV was successful in 97.5% of subjects. The 30-day all-cause mortality, cardiovascular mortality, and disabling stroke rates were 2.6%, 2.1%, and 1.8%, respectively. A new pacemaker was implanted in 19.0% of subjects at 30 days. At 30 days, the effective orifice area and mean gradient values were 1.82 cm2 and 7.1 mmHg, respectively. The 30-day rate of moderate paravalvular leak (PVL) was 2.1%, with no occurrence of severe PVL. The Portico™ THV demonstrated improved hemodynamic performance and low rates of safety events at 30 days in a large cohort of subjects implanted with the Portico™ THV with either the first-generation DS or FlexNav™ DS.

17.
J Am Chem Soc ; 133(34): 13646-51, 2011 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-21774550

RESUMO

The introduction of multidimensional NMR spectroscopy was a breakthrough in biological NMR methodology because it allowed the unequivocal correlation of different spin states of the system. The introduction of large pressure perturbations in the corresponding radio frequency (RF) pulse sequences adds an extra structural dimension into these experiments. We have developed a microprocessor-controlled pressure jump unit that is able to introduce fast, strong pressure changes at any point in the pulse sequences. Repetitive pressure changes of 80 MPa in the sample tube are thus feasible in less than 30 ms. Two general forms of these experiments are proposed here, the pressure perturbation transient state spectroscopy (PPTSS) and the pressure perturbation state correlation spectroscopy (PPSCS). PPTSS can be used to measure the rate constants and the activation energies and activation volumes for the transition between different conformational states including the folded and unfolded state of proteins, for polymerization-depolymerization processes, and for ligand binding at atomic resolution. PPSCS spectroscopy correlates the NMR parameters of different pressure-induced states of the system, thus allowing the measurement of properties of a given pressure induced state such as a folding intermediate in a different state, for example, the folded state. Selected examples for PPTSS and PPSCS spectroscopy are presented in this Article.


Assuntos
Proteínas de Bactérias/química , Ressonância Magnética Nuclear Biomolecular/instrumentação , Staphylococcus/química , Desenho de Equipamento , Pressão , Conformação Proteica , Dobramento de Proteína
18.
J Nanosci Nanotechnol ; 11(9): 8024-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22097523

RESUMO

Thin film solar cell techniques can effectively reduce the costs for photovoltaic solar power. However, most of these techniques still have the disadvantage of a comparatively low efficiency. One way to realize a thin film solar cell concept with high efficiency potential is the crystalline silicon thin-film (cSiTF) concept. Following the high-temperature approach, this concept is based on a silicon epitaxy process. This paper reports the current status of the development of a high throughput epitaxy tool at Fraunhofer ISE and presents first results. Also presented is the development of a simulation tool which is a virtual image of the real setup in order to forecast save deposition conditions. The presented epitaxy tool is the ConCVD (Continuous Chemical Vapour Deposition), in which an improved reactor setup has been installed, based on the experience gained so far. To provide insight into upcoming further advances, the industrial scale epitaxy tool ProConCVD is presented as well.

19.
Br J Radiol ; 94(1124): 20201306, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34233477

RESUMO

OBJECTIVES: Computed tomography (CT) allows reproducible assessment of left ventricular (LV) function, left ventricular outflow tract area (LVOTarea) and aortic valve area (AVA). We evaluated the influence of image reconstruction parameters on these measurements. METHODS: We analyzed 45 contrast-enhanced, retrospectively ECG-gated CT datasets acquired on a third-generation dual source system. A standard filtered-back-projection data set (20 cardiac phases (5% steps, 0-95%), 0.6-mm-slice thickness, 512 × 512 matrix) and eight reconstructions with modified slice thickness (1-8 mm), number of cardiac phases (5, 10), matrix size (256×256) and an iterative reconstruction (IR) algorithm were obtained. LV parameters (ejection fraction (EF), stroke volume (SV), end-diastolic (EDV), end-systolic volumes (ESV)), LVOTarea and AVA were assessed. RESULTS: Differences in LV parameters, LVOTarea and AVA, were only minimal between standard reconstructions and those with modified matrix size, IR algorithm and ≤2 mm slice thickness, while reconstructions with 8-mm slice thickness significantly overestimated SV (p < 0.001) and EDV (p = 0.016). AVA planimetry in reconstructions with ≥5 mm slice thickness was not feasible in 56% of patients. A decrease in the number of reconstructed phases (10 or 5) underestimated EF, SV, EDV, LVOTarea and AVA and overestimated ESV. CONCLUSIONS: Modifications of reconstruction parameters (except a slice thickness ≤2 mm) have only a marginal effect on LV, LVOTarea and AVA assessment. However, a reduced number of reconstructions per cardiac cycle may significantly influence measurements. ADVANCES IN KNOWLEDGE: Substantial modifications in number of reconstructions per cardiac cycle significantly affect the assessment of LV function, LVOTarea and AVA also in modern CT scanners.


Assuntos
Valva Aórtica/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
Front Cardiovasc Med ; 8: 619605, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33614749

RESUMO

Transcatheter techniques for the treatment of tricuspid regurgitation (TR) are being more frequently used and several new devices are in development. Since 90% of patients with TR have secondary TR, catheter based systems which reduce the dilated tricuspid annulus area are of particular interest. In order to perform an annuloplasty procedure effectively and safely, knowledge about the anatomy of the tricuspid valve apparatus and especially of the annulus in relation to the important neighboring structures such as the aortic root, the RCA, the electrical pathways and the CS is fundamental. In addition, comprehensive understanding of the device itself, the delivery system, its maneuverability and the individual procedural steps is required. Furthermore, the use of multi-modality imaging is important. For each step of the procedure the appropriate imaging modality as well as the optimal; imaging planes are crucial to provide the necessary information to best guide the individual procedural step.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA