1.
J Appl Clin Med Phys ; 24(1): e13834, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36333951

RESUMO

OBJECTIVE: To estimate the minimum iodine concentrations detectable in simulated vessels of various diameters for both subtraction computed tomography (CT) and dual-energy CT systems. METHODS: Fillable tubes (diameters: 1, 3, and 5 mm) were filled with a variety of iodine concentrations (range: 0-20 mg/ml), placed in the center of 28-mm cylindrical rods and surrounded with water. Rods with and without fillable tubes were placed in a 20-cm cylindrical solid-water phantom to simulate administration of iodine in blood vessels. The phantom was scanned with clinical subtraction CT (SCT) and dual-energy CT (DECT) head protocols to assess the detection of minimum iodine concentrations in both systems. The SCT and DECT images were evaluated quantitatively with a MATLAB script to extract regions of interest (ROIs) of each simulated vessel. ROI measurements were used to calculate the limit of detectability (LOD) and signal-to-noise ratio of Rose criteria for the assessment of the contrast thresholds. RESULTS: Both SNRRose and LOD methods agreed and determined the minimum detectable iodine concentration to be 0.4 mg/ml in the 5-mm diameter vessel for SCT. However, the minimum detectable concentration in the 5-mm vessel with DECT was 1 mg/ml. The 3-mm vessel had a minimum detectable concentration of 0.8 mg/ml for SCT and 2 mg/ml for DECT. Lastly, the minimum detectable iodine concentration for the 1-mm vessel was 10 mg/ml for SCT and 10 mg/ml for DECT. CONCLUSION: In this phantom study, SCT showed the capability to detect lower iodine concentrations compared to DECT. Contrast thresholds varied for vessels of different diameters and the smaller vessels required a higher iodine concentration for detection. Based on this knowledge, radiologists can modify their protocols to increase contrast enhancement.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Razão Sinal-Ruído , Meios de Contraste , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
2.
J Appl Clin Med Phys ; 23(10): e13751, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35976771

RESUMO

Time-of-flight (TOF) and resolution modeling (RM) algorithms are frequently used in clinical PET images, and inclusion of these corrections should measurably improve image quality. We quantified the effects of these correction algorithms on reconstructed images via the following metrics: recovery coefficients (RCs), contrast-to-noise ratio (CNR), noise-power spectrum (NPS), modulation transfer function (MTF), and the full width at half maximum (FWHM) of a point source. The goal of this experiment was to assess the effects of the correction algorithms when applied singly or together. Two different phantom tests were performed and analyzed by custom software. FWHM and MTF were measured using capillary tube point sources, while RCs, CNR, and NPS were measured using an image quality body phantom. Images were reconstructed with both TOF and RM, only TOF, only RM, or neither correction. The remaining reconstruction parameters used the standard clinical protocol. RM improved RCs, FWHM, and MTF, without increasing overall noise significantly. TOF improves CNR for small objects FWHM or MTF but did not decrease noise. RCs were not statistically improved by enabling these algorithms. Inclusion of both correction algorithms in image reconstruction provides an overall improvement to all metrics relative to the uncorrected image, but not by a significant margin in multiple aspects.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas , Algoritmos
3.
J Appl Clin Med Phys ; 22(11): 126-142, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34623023

RESUMO

Radiography remains the most widely used imaging modality throughout the world. Additionally, while it has been demonstrated that a quality control (QC) program, especially in mammography, improves image quality, weekly technologist QC testing might be lacking even where there is clinical qualified medical physicist (CQMP) support. Therefore, the International Atomic Energy Agency (IAEA) developed simple QC phantoms that can easily be used on a regular basis (daily/weekly) for radiography and mammography. These are simple in design and use materials that are easily accessible in most parts of the world. A software application is also developed that automatically analyzes images and Digital Imaging and Communications in Medicine (DICOM) header information. It exports data to a comma-separated values (CSV) file that is read by a Microsoft Excel® spreadsheet for documentation and graphical analysis. The phantom and the software were tested in four institutions (in Costa Rica and the United States of America) both on computed radiography and direct digital mammography and radiography systems. Data were collected over a 3-year period. No corrective actions were taken on the data, but service was performed on two of the units. Results demonstrated noise that could be attributed to suboptimal placement of the phantom and incorrect data being put into the DICOM header. Preliminary evaluation of the IAEA methodology has demonstrated that it can provide meaningful QC data that are sensitive to changes in the imaging systems. Care must be taken at implementation to properly train personnel and ensure that the image data, including the DICOM header, are being correctly transmitted. The methodology gives the opportunity for a single CQMP to provide QC services even to remote sites where travel is prohibitive, and it is feasible and easy to implement.


Assuntos
Mamografia , Energia Nuclear , Humanos , Agências Internacionais , Imagens de Fantasmas , Controle de Qualidade
4.
J Appl Clin Med Phys ; 20(6): 141-151, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31050136

RESUMO

The purpose of this study was to investigate the frequency and impact of vertical mis-centering on organ doses in computed tomography (CT) exams and evaluate the effect of a commercially available positioning compensation system (PCS). Mis-centering frequency and magnitude was retrospectively measured in 300 patients examined with chest-abdomen-pelvis CT. Organ doses were measured in three postmortem subjects scanned on a CT scanner at nine different vertical table positions (maximum shift ± 4 cm). Organ doses were measured with optically stimulated luminescent dosimeters inserted within organs. Regression analysis was performed to determine the correlation between organ doses and mis-centering. Methods were repeated using a PCS that automatically detects the table offset to adjust tube current output accordingly. Clinical mis-centering was >1 cm in 53% and 21% of patients in the vertical and lateral directions, respectively. The 1-cm table shifts resulted in organ dose differences up to 8%, while 4-cm shifts resulted in organ dose differences up to 35%. Organ doses increased linearly with superior table shifts for the lung, colon, uterus, ovaries, and skin (R2  = 0.73-0.99, P < 0.005). When the PCS was utilized, organ doses decreased with superior table shifts and dose differences were lower (average 5%, maximum 18%) than scans performed without PCS (average 9%, maximum 35%) at all table shifts. Mis-centering occurs frequently in the clinic and has a significant effect on patient dose. While accurate patient positioning remains important for maintaining optimal imaging conditions, a PCS has been shown to reduce the effects of patient mis-centering.


Assuntos
Abdome/efeitos da radiação , Processamento de Imagem Assistida por Computador/métodos , Posicionamento do Paciente , Pelve/efeitos da radiação , Tórax/efeitos da radiação , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Abdome/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Pelve/diagnóstico por imagem , Pelve/patologia , Doses de Radiação , Estudos Retrospectivos , Tórax/diagnóstico por imagem , Tórax/patologia , Tomógrafos Computadorizados , Adulto Jovem
5.
J Urol ; 195(4 Pt 1): 992-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26527512

RESUMO

PURPOSE: Proper fluoroscopic education and protocols may reduce the patient radiation dose but few prospective studies in urology have been performed. Using optically stimulated luminescent dosimeters we tested whether fluoroscopy time and/or entrance skin dose would decrease after educational and radiation reduction protocols. MATERIALS AND METHODS: At default manufacturer settings fluoroscopy time and entrance skin dose were prospectively measured using optically stimulated luminescent dosimeters in patients undergoing ureteroscopy, retrograde pyelogram/stent or percutaneous nephrolithotomy with access for stone disease. A validated radiation safety competency test was administered to urology faculty and residents before and after web based, hands-on fluoroscopy training. Default fluoroscopy settings were changed from continuous to intermittent pulse rate and from standard to half-dose output. Fluoroscopy time and entrance skin dose were then measured again. RESULTS: The cohorts of 44 pre-protocol and 50 post-protocol patients with stones were similarly matched. The change in mean fluoroscopy time and entrance skin dose from pre-protocol to post-protocol was -0.6 minutes and -11.6 mGy (33%) for percutaneous nephrolithotomy (p = 0.62 and <0.001), 0.5 minutes and -0.1 mGy (34%) for ureteroscopy (p = 0.42 and 0.31), and 0.1 minute and -0.1 mGy (29%) for retrograde pyelogram/stent (p = 0.85 and 0.49, respectively). Urologist post-training test scores increased 30% from pretraining scores (p = 0.1). CONCLUSIONS: Radiation safety training protocols improved clinical knowledge but did not significantly alter fluoroscopy time. Changing equipment default settings to intermittent pulse rate (12 frames per second) and half-dose lowered the entrance skin dose by 30% across all endourology patients but most significantly during percutaneous nephrolithotomy. To limit patient radiation exposure fluoroscopy default settings should be decreased before all endourology procedures and image equipment manufacturers should consider lowering standard default renal settings.


Assuntos
Cálculos Renais/terapia , Nefrostomia Percutânea/métodos , Doses de Radiação , Pele/efeitos da radiação , Ureteroscopia/métodos , Adulto , Protocolos Clínicos , Feminino , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Radiology ; 277(2): 471-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26110666

RESUMO

PURPOSE: To generate empirical sets of equations that can be used to calculate patient-specific organ doses resulting from a group of computed tomographic (CT) studies by using data from direct dose measurements performed within a human body. MATERIALS AND METHODS: Organ dose measurements were obtained in eight postmortem female subjects. A chest-abdomen-pelvis protocol was used for this study. The relationships among measured organ doses, body mass index, effective diameter (D(eff)), and volume CT dose index (CTDI(vol)) were investigated. Organ dose equations were developed by means of linear regression from organ dose data, with CTDI(vol) and D(eff) as variables, by using Pearson correlation coefficients and P values to determine correlation strength of fit. Measured organ doses were compared with corresponding size-specific dose estimates (SSDEs). RESULTS: The central-section D(eff) presented similar correlations with organ doses to those from D(eff) measured at specific organ locations. The strongest correlations were observed between the central-section D(eff) and CTDI(vol)-normalized organ doses (R(2): 0.478-0.941). The average of measured organ doses for each subject resulted in an average difference of only 5% from SSDE-calculated doses; however, individual organ doses differed from +31% to -61% from the calculated SSDE. CONCLUSION: The organ dose equations developed represent a method for organ dose estimation from direct organ dose measurements that can estimate organ doses more accurately than the calculated SSDE, which provides a less-specific patient dose estimate.


Assuntos
Doses de Radiação , Exposição à Radiação/análise , Radiometria/métodos , Tomografia Computadorizada por Raios X , Algoritmos , Tamanho Corporal , Cadáver , Feminino , Humanos , Especificidade de Órgãos
7.
Radiology ; 277(2): 463-70, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26043262

RESUMO

PURPOSE: To develop a methodology that allows direct measurement of organ doses from computed tomographic (CT) examinations of postmortem subjects. MATERIALS AND METHODS: In this institutional review board approved study, the x-ray linear attenuation coefficients of various tissues were calculated from the mean CT numbers of images that were obtained in eight embalmed adult female cadavers and compared with the corresponding linear attenuation coefficients calculated from CT images obtained in eight living patients that were body mass index (BMI)-matched. Dosimetry was performed in three of the cadavers by accessing organs of interest and affixing partially sealed vinyl tubes inside them. Optically stimulated luminescent dosimeters (OSLDs) were inserted into the tubes and positioned within the organs of interest and on the skin. OSLDs were read with an InLight MicroStar (Landauer, Glenwood, Ill) reader, and readings were corrected for energy and scatter response. Fifteen tubes containing dosimeters were used, and imaging was repeated twice in each cadaver, for a total of five standard clinical protocols. Average dosimetry values were used for analysis. RESULTS: Differences in linear attenuation coefficients between living and embalmed cadaveric tissues were within 3% for the tissues investigated. Measured organ doses for a chest-abdomen-pelvis CT protocol were less than 32 mGy for all organs measured. Organs that were completely irradiated during a given examination received similar doses, whereas organs that were partially irradiated displayed a large variation in measured organ dose. CONCLUSION: The anatomic and radiation attenuation characteristics of cadavers are comparable to those of living human tissue. This methodology allows direct measurement of organ doses from clinical CT examinations.


Assuntos
Doses de Radiação , Exposição à Radiação/análise , Radiometria/métodos , Tomografia Computadorizada por Raios X , Cadáver , Feminino , Humanos , Especificidade de Órgãos
8.
Semin Roentgenol ; 58(2): 152-157, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37087135

RESUMO

Health informatics and artificial intelligence (AI) are expected to transform the healthcare enterprise and the future practice of radiology. There is an increasing body of literature on radiomics and deep learning/AI applications in medical imaging. There are also a steadily increasing number of FDA cleared AI applications in radiology. It is therefore essential for radiologists to have a basic understanding of these approaches, whether in academia or private practice. In this article, we will provide an overview of the field and familiarize the readers with the fundamental concepts behind these approaches.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Radiologistas , Radiologia/métodos , Radiografia , Previsões
9.
Med Phys ; 48(7): 3525-3539, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33932301

RESUMO

PURPOSE: This study assesses the accuracy of effective atomic number (Zeff ) and electron density measurements acquired from dual energy CT and characterizes the response to clinically relevant variables representative of challenges in patient imaging, including: phantom size, material position within the phantom, variation over time, off-center positioning, and large cone beam angle. METHODS: The Gammex Multi-Energy CT head and body phantoms were used to measure Zeff and electron density from 35 rod inserts that mimic tissues and varying concentrations of iodine and calcium. Scans were performed on a Canon Aquilion ONE Genesis CT scanner over a period of 6 months using default dual energy protocols appropriate for each phantom size. Theoretical Zeff and electron density values were calculated using data provided by the phantom manufacturer and compared to the measurements. Sources of variance were separated and quantified to identify the influences of random photon statistics, ROI placement, and variation over time. A subset of measurements were repeated with the phantom shifted in the vertical and horizontal directions, and over all slices in the volumetric scan. RESULTS: All measurements showed strong correlation (r > 0.98) with their corresponding theoretical values; however, the system did demonstrate a bias of -0.58 atomic units in the body phantom and 0.28 atomic units in the head phantom for Zeff measurements. The mean absolute percent error (MAPE) was 6.3% for the body phantom and 3.2% for the head phantom. Electron density measurements of the body and head phantoms gave MAPE values of 4.6% and 1.0%, respectively. Zeff and electron density measurements significantly varied within the solid water background, showing a positional dependence within the phantom that dominated the total standard deviation in measurements. Zeff values dropped by 0.2 atomic units when the phantom was off-center; electron density measurements were less affected by phantom position. Along the z-axis, the accuracy drops off markedly at more than 50-60 mm from the central slice. CONCLUSION: The Canon dual energy system offers an accurate way of measuring the Zeff and electron density of clinically relevant materials. Accuracy could be improved further by calibration to remove bias, careful attention to centering within the FOV, and avoiding measurements at the edges of the cone beam.


Assuntos
Elétrons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Tomógrafos Computadorizados
10.
Phys Med Biol ; 66(12)2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-34015770

RESUMO

Modern CT iterative reconstruction algorithms are transitioning from a statistical-based to model-based approach. However, increasing complexity does not ensure improved image quality for all indications, and thorough characterization of new algorithms is important to understand their potential clinical impacts. This study performs both quantitative and qualitative analyses of image quality to compare Canon's statistical-based Adaptive Iterative Dose Reduction 3D (AIDR 3D) algorithm to its model-based algorithm, Forward-projected model-based Iterative Reconstruction SoluTion(FIRST). A phantom was used to measure the task-specific modulation transfer function (MTFTask), the noise power spectrum (NPS), and the low-contrast object-specific CNR (CNRLO) for each algorithm using three dose levels and the convolution algorithm (kernel) appropriate for abdomen, lung, and brain imaging. Additionally, MTFTaskwas measured at four contrast levels, and CNRLOwas measured for two object sizes. Lastly, three radiologists participated in a preference study to compare clinical image quality for three study types: non-contrast abdomen, pulmonary embolism (PE), and lung screening. Nine questions related to the appearance of anatomical features or image quality characteristics were scored for twenty exams of each type. The behavior of both algorithms depended strongly on the kernel selected. Phantom measurements suggest that FIRST should be beneficial over AIDR 3D for abdomen imaging, but do not suggest a clear overall benefit to FIRST for lung or brain imaging; metrics suggest performance may be equivalent to or slightly favor AIDR 3D, depending on the size of the object being imaged and whether spatial resolution or low-contrast resolution is more important for the task at hand. Overall, radiologists strongly preferred AIDR 3D for lung screening, slightly preferred AIDR 3D for non-contrast abdomen, and had no preference for PE. FIRST was superior for the reduction of metal artifacts. Radiologist preference may be influenced by changes to noise texture.


Assuntos
Redução da Medicação , Tomografia Computadorizada por Raios X , Algoritmos , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
11.
J Digit Imaging ; 23(6): 666-73, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19466499

RESUMO

Workflow efficiency is a crucial factor in selecting computed radiography (CR) versus digital radiography (DR) systems for digital projection radiography operations. DR systems can be more efficient, but present higher costs and limitations in performing some radiographic exams. A newly developed CR system presents a good alternative with its faster line-by-line instead of pixel-by-pixel image plate-scanning technology and a more efficient workstation. To evaluate workflow characteristics, a time-motion study was conducted to compare radiographic exam times of the new CR system with traditional CR and DR systems in a high-volume orthopedic operation. Approximately 200 exams for each modality were documented from the moment when a patient entered the X-ray room to the moment when all images were sent to the PACS archive using a timer and speech-recognition software. Applying Welch ANOVA and Tamhane's T2 tests, average exam times for the new CR system were significantly faster (18-42%; P ≤ 0.025) than for the traditional CR system. Average exam times for the DR system were also faster than for the new CR system by 22-36% (P<0.001) with one exception. In the case where the new CR system was located outside the X-ray room, using a one-technologist workflow model, average single-study exam times were not significantly different from those found when using DR. Therefore, the new CR system may be comparable in efficiency with the DR system for this particular setting and operation.


Assuntos
Ortopedia , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Fluxo de Trabalho , Eficiência , Humanos , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/tendências , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação
12.
Eur J Radiol ; 133: 109357, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33126172

RESUMO

OBJECTIVES: The purpose of this study was to compare the effectiveness of metal artifact reduction using Single Energy Metal Artifact Reduction (SEMAR) and Dual Energy CT (DECT). MATERIALS AND METHODS: Six cadavers containing metal implants in the head, neck, abdomen, pelvis, and extremities were scanned with Standard, SEMAR, and DECT protocols on a 320-slice CT scanner. Four specialized radiologists blinded to acquisition methods rated severity of metal artifacts, visualization of anatomic structures, diagnostic interpretation, and image preference with a 5-point grading scale. RESULTS: Scores were significantly better for SEMAR than Standard images in the hip, knee, pelvis, abdomen, and maxillofacial scans (3.25 ±â€¯0.88 versus 2.14 ±â€¯0.93, p < 0.001). However, new reconstruction artifacts developed in SEMAR images that were not present in Standard images. Scores for severity of metal artifacts and visualization of smooth structures were significantly better for DECT than Standard images in the cervical spine (3.50±0.50 versus 2.0±0.58, p < 0.001) and was preferred over Standard images by one radiologist. In all other cases, radiologists preferred the Standard image over the DECT image due to increased image noise and reduced low-contrast resolution with DECT. In all cases, SEMAR was preferred over Standard and DECT images. CONCLUSION: SEMAR was more effective at reducing metal artifacts than DECT. Radiologists should be aware of new artifacts and review both the original and SEMAR images. When the anatomy or implant is relatively small, DECT may be superior to SEMAR without additional artifacts. However, radiologist should be aware of a reduction in soft tissue contrast.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Algoritmos , Cadáver , Humanos , Próteses e Implantes
13.
Biomed Res Int ; 2018: 5120974, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30363655

RESUMO

OBJECTIVE: To compare organ specific radiation dose and image quality in kidney stone patients scanned with standard CT reconstructed with filtered back projection (FBP-CT) to those scanned with low dose CT reconstructed with iterative techniques (IR-CT). MATERIALS AND METHODS: Over a one-year study period, adult kidney stone patients were retrospectively netted to capture the use of noncontrasted, stone protocol CT in one of six institutional scanners (four FBP and two IR). To limit potential CT-unit use bias, scans were included only from days when all six scanners were functioning. Organ dose was calculated using volumetric CT dose index and patient effective body diameter through validated conversion equations derived from previous cadaveric, dosimetry studies. Board-certified radiologists, blinded to CT algorithm type, assessed stone characteristics, study noise, and image quality of both techniques. RESULTS: FBP-CT (n=250) and IR-CT (n=90) groups were similar in regard to gender, race, body mass index (mean BMI = 30.3), and stone burden detected (mean size 5.4 ± 1.2 mm). Mean organ-specific dose (OSD) was 54-62% lower across all organs for IR-CT compared to FBP-CT with particularly reduced doses (up to 4.6-fold) noted in patients with normal BMI range. No differences were noted in radiological assessment of image quality or noise between the cohorts, and intrarater agreement was highly correlated for noise (AC2=0.873) and quality (AC2=0.874) between blinded radiologists. CONCLUSIONS: Image quality and stone burden assessment were maintained between standard FBP and low dose IR groups, but IR-CT decreased mean OSD by 50%. Both urologists and radiologists should advocate for low dose CT, utilizing reconstructive protocols like IR, to reduce radiation exposure in their stone formers who undergo multiple CTs.


Assuntos
Cálculos Renais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Estudos Retrospectivos , Adulto Jovem
14.
World Neurosurg ; 110: e636-e641, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29180081

RESUMO

BACKGROUND: In some fluoroscopy machines, the dose-rate output of the fluoroscope is tied to a selectable patient size. Although patient size may play a significant role in visceral or cardiac procedures, head morphology is less variable, and high dose outputs may not be necessary even in very obese patients. We hypothesized that very small patient size setting can be used to reduce dose for cerebral angiography without compromising image quality. METHODS: Patients who underwent endovascular neurosurgical procedures during the 2015-2016 academic year were identified, and estimated procedural air kerma (AK) was tabulated retrospectively. Technologists were instructed to begin using the very small patient size setting for all procedures performed using our Philips Allura Xper FD20 biplane fluoroscopy system beginning in March 2016. No changes were made in a second procedure room using a Toshiba Infinix system. Student t tests and logistic regression models were used to compare radiation exposure before and after March 1, 2016, for both machines. RESULTS: For diagnostic cerebral angiograms performed on the Philips system (n = 302), AK was reduced by approximately 17% (1277 vs. 1061 mGy; P = 0.0006.) Changes in table height, total fluoroscopy time, patient weight, and body mass index did not contribute to this difference. No significant change was seen in total AK using the Toshiba system (n = 237). Blinded review by a neuroradiologist did not demonstrate any change in image quality. CONCLUSIONS: Using the very small patient size reduces fluoroscopy dose by 17% for cerebral angiography without impacting image quality.


Assuntos
Peso Corporal , Angiografia Cerebral , Procedimentos Endovasculares , Fluoroscopia , Procedimentos Neurocirúrgicos , Cirurgia Assistida por Computador , Angiografia Cerebral/instrumentação , Angiografia Cerebral/métodos , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Humanos , Modelos Logísticos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos
15.
Med Phys ; 34(1): 294-306, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17278515

RESUMO

The time-sequence videotape-analysis methodology, developed [Sulieman et al., Radiology 178, 653-658 (1991)] for use in tissue dose estimations in adult fluoroscopy examinations and utilized [Bolch et al., Med. Phys. 30, 667-680 (2003)] for analog fluoroscopy in newborn patients, has been extended to the study of digital fluoroscopic examinations of the urinary bladder in newborn and infant female patients. Individual frames of the fluoroscopic and radiographic video were analyzed with respect to unique combinations of field size, field center, projection, tube potential, and tube current (mA), and integral tube current (mAs), respectively. The dosimetry study was conducted on five female patients of ages ranging from four-days to 66 days. For each patient, three different phantoms were utilized: a stylized computational phantom of the reference newborn (3.5 kg), a tomographic computational phantom of the reference newborn (3.5 kg), and (3) a tomographic computational phantom uniformly rescaled to match patient total-body mass. The latter phantom set circumvented the need for mass-dependent rescaling of recorded technique factors (kVp, mA, mAs, etc.), and thus represented the highest degree of patient specificity in the individual organ dose assessment. Effective dose values for the voiding cystourethrogram examination ranged from 0.6 to 3.2 mSv, with a mean and standard deviation of 1.8+/-0.9 mSv. The ovary and colon equivalent doses contributed in total approximately 65%-80% of the effective dose in these fluoroscopy studies. Percent differences in the effective dose assessed using the two tomographic phantoms (one fixed at 3.5 kg with rescaled technique factors rescaled and one physically rescaled to individual patient masses with no adjustment of recorded technique factors) ranged for -49% to +15%. Percent differences in effective dose found using the 3.5 kg stylized phantom and the 3.5 kg tomographic phantom, both with patient-specific rescaling of technique factors, ranged from -10% to +17%. These differences are due in part to a reduced ovary dose in the tomographic phantom for right posterior oblique (RPO) views when compared to those seen in the stylized phantom.


Assuntos
Imagens de Fantasmas , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Urografia/métodos , Gravação em Vídeo/métodos , Carga Corporal (Radioterapia) , Feminino , Humanos , Lactente , Recém-Nascido , Especificidade de Órgãos , Doses de Radiação , Eficiência Biológica Relativa , Tomografia Computadorizada por Raios X/instrumentação , Micção , Urografia/instrumentação
16.
Med Phys ; 34(2): 703-10, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17388188

RESUMO

To provide more detailed data on organ and effective doses in digital upper gastrointestinal (UGI) fluoroscopy studies of newborns and infants, the present study was conducted employing the time-sequence videotape-analysis technique used in a companion study of newborn and infant voiding cystourethrograms (VCUG). This technique was originally pioneered [O. H. Suleiman, J. Anderson, B. Jones, G. U. Rao, and M. Rosenstein, Radiology 178, 653-658 (1991)] for adult UGI examinations. Individual video frames were analyzed to include combinations of field size, field center, x-ray projection, image intensifier, and magnification mode. Additionally, the peak tube potential and the mA or mAs values for each segment/subsegment or digital photospot were recorded for both the fluoroscopic and radiographic modes of operation. The data from videotape analysis were then used in conjunction with a patient-scalable newborn tomographic computational phantom to report both organ and effective dose values via Monte Carlo radiation transport. The study includes dose estimates for five simulated UGI examinations representative of patients ranging from three to six months of age. Effective dose values for UGI examinations ranged from 1.17 to 6.47 mSv, with a mean of 3.14 mSv and a large standard deviation of 2.15 mSv. The colon, lungs, stomach, liver, and esophagus absorbed doses in sum were found to constitute between 63 and 75% of the effective dose in these UGI studies. Representing 23-30% of the effective dose, the lungs were found to be the most significant organ in the effective dose calculation. Approximately 80-95% of the effective dose is contributed by the dynamic fluoroscopy segments with larger percentages found in longer studies. The mean effective dose for newborn UGI examinations was not found to be statistically different from that seen in newborn VCUG examinations.


Assuntos
Fluoroscopia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Trato Gastrointestinal Superior/diagnóstico por imagem , Carga Corporal (Radioterapia) , Humanos , Lactente , Recém-Nascido , Especificidade de Órgãos , Doses de Radiação , Eficiência Biológica Relativa , Medição de Risco/métodos , Fatores de Risco , Gravação em Vídeo/métodos
17.
Med Phys ; 34(5): 1858-73, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17555267

RESUMO

As multidetector computed tomography (CT) serves as an increasingly frequent diagnostic modality, radiation risks to patients became a greater concern, especially for children due to their inherently higher radiosensitivity to stochastic radiation damage. Current dose evaluation protocols include the computed tomography dose index (CTDI) or point detector measurements using anthropomorphic phantoms that do not sufficiently provide accurate information of the organ-averaged absorbed dose and corresponding effective dose to pediatric patients. In this study, organ and effective doses to pediatric patients under helical multislice computed tomography (MSCT) examinations were evaluated using an extensive series of anthropomorphic computational phantoms and Monte Carlo radiation transport simulations. Ten pediatric phantoms, five stylized (equation-based) ORNL phantoms (newborn, 1-year, 5-year, 10-year, and 15-year) and five tomographic (voxel-based) UF phantoms (9-month male, 4-year female, 8-year female, 11-year male, and 14-year male) were implemented into MCNPX for simulation, where a source subroutine was written to explicitly simulate the helical motion of the CT x-ray source and the fan beam angle and collimator width. Ionization chamber measurements were performed and used to normalize the Monte Carlo simulation results. On average, for the same tube current setting, a tube potential of 100 kVp resulted in effective doses that were 105% higher than seen at 80 kVp, and 210% higher at 120 kVp regardless of phantom type. Overall, the ORNL phantom series was shown to yield values of effective dose that were reasonably consistent with those of the gender-specific UF phantom series for CT examinations of the head, pelvis, and torso. However, the ORNL phantoms consistently overestimated values of the effective dose as seen in the UF phantom for MSCT scans of the chest, and underestimated values of the effective dose for abdominal CT scans. These discrepancies increased with increasing kVp. Finally, absorbed doses to select radiation sensitive organs such as the gonads, red bone marrow, colon, and thyroid were evaluated and compared between phantom types. Specific anatomical problems identified in the stylized phantoms included excessive pelvic shielding of the ovaries in the female phantoms, enhanced red bone marrow dose to the arms and rib cage for chest exams, an unrealistic and constant torso thickness resulting in excessive x-ray attenuation in the regions of the abdominal organs, and incorrect positioning of the thyroid within the stylized phantom neck resulting in insufficient shielding by clavicles and scapulae for lateral beam angles. To ensure more accurate estimates of organ absorbed dose in multislice CT, it is recommended that voxel-based phantoms, potentially tailored to individual body morphometry, be utilized in any future prospective epidemiological studies of medically exposed children.


Assuntos
Método de Monte Carlo , Imagens de Fantasmas , Tomografia Computadorizada Espiral/métodos , Adolescente , Fatores Etários , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação
18.
Med Phys ; 33(9): 3283-9, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17022223

RESUMO

Following the recent completion of a tomographic physical newborn dosimetry phantom with incorporated metal-oxide-semiconductor field effect transistor (MOSFET) dosimetry system, it was necessary to derive scaling factors in order to calculate organ doses in the physical phantom given point dose measurements via the MOSFET dosimeters (preceding article in this issue). In this study, we present the initial development of scaling factors using projection radiograph data. These point-to-organ dose scaling factors (SF(POD)) were calculated using a computational phantom created from the same data set as the physical phantom, but which also includes numerous segmented internal organs and tissues. The creation of these scaling factors is discussed, as well as the errors associated when using only point dose measurements to calculate mean organ doses and effective doses in physical phantoms. Scaling factors for various organs ranged from as low as 0.70 to as high as 1.71. Also, the ability to incorporate improvements in the computational phantom into the physical phantom using scaling factors is discussed. An comprehensive set of SF(POD) values is presented in this article for application in pediatric radiography of newborn patients.


Assuntos
Modelos Biológicos , Especificidade de Órgãos , Imagens de Fantasmas , Radiometria/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Imagem Corporal Total/instrumentação , Contagem Corporal Total/instrumentação , Carga Corporal (Radioterapia) , Simulação por Computador , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Recém-Nascido , Doses de Radiação , Radiometria/métodos , Eficiência Biológica Relativa , Medição de Risco/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Contagem Corporal Total/métodos
19.
Phys Med Biol ; 51(20): 5151-66, 2006 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-17019030

RESUMO

In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used to model the patient anatomy was the revised ORNL newborn phantom by Han et al (2006 Health Phys.90 337). The tomographic phantom used in the study was that developed by Nipper et al (2002 Phys. Med. Biol. 47 3143) as recently revised by Staton et al (2006 Med. Phys. 33 3283). The stylized model was implemented within the MCNP5 radiation transport code, while the tomographic phantom was incorporated within the EGSnrc code. In both codes, the x-ray source was modelled as a fan beam originating from the focal spot at a fan angle of 52 degrees and a focal-spot-to-axis distance of 57 cm. The helical path of the source was explicitly modelled based on variations in collimator setting (12 mm or 24 mm), detector pitch and scan length. Tube potentials of 80, 100 and 120 kVp were considered in this study. Beam profile data were acquired using radiological film measurements on a 16 cm PMMA phantom, which yielded effective beam widths of 14.7 mm and 26.8 mm for collimator settings of 12 mm and 24 mm, respectively. Values of absolute organ absorbed dose were determined via the use of normalization factors defined as the ratio of the CTDI(100) measured in-phantom and that determined by Monte Carlo simulation of the PMMA phantom and ion chamber. Across various technique factors, effective dose differences between the stylized and tomographic phantoms ranged from +2% to +9% for head exams, -4% to -2% for chest exams, +8% to +24% for abdominal exams, -16% to -12% for pelvic exams and -7% to 0% for chest-abdomen-pelvis (CAP) exams. In many cases, however, relatively close agreement in effective dose was accomplished at the expense of compensating errors in individual organ dose. Per cent differences in organ dose between the stylized and tomographic phantoms at 120 kVp and 12 mm collimator setting ranged from -25% (skin) to +164% (muscle) for head exams, -92% (thyroid) to +98% (ovaries) for chest exams, -144% (uterus) to +112% (ovaries) for abdominal exams, -98% (SI wall) to +20% (thymus) for pelvic exams and -60% (extrathoracic airways) to +13% (ovaries) for CAP exams. Better agreement was seen between the two phantom types for organs entirely within the scan field. In these cases, corresponding per cent differences in organ absorbed dose did not vary more than 17%. For all scans, the effective dose was found to range approximately 1-13 mSv across the scan parameters and scan regions. The largest effective dose occurred for CAP scans at 120 kVp.


Assuntos
Modelos Biológicos , Especificidade de Órgãos , Tomografia Computadorizada Espiral , Contagem Corporal Total/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Recém-Nascido , Imagens de Fantasmas , Doses de Radiação , Eficiência Biológica Relativa
20.
J Bone Joint Surg Am ; 87(1): 13-7, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15634810

RESUMO

BACKGROUND: The use of mobile fluoroscopic devices during orthopaedic procedures is associated with substantial concern with regard to the radiation exposure to surgeons and support staff. The perceived increased risks associated with large c-arm devices have been well documented. However, no study to date has documented the relative radiation risk associated with the use of a mini-c-arm device. The purpose of the current study was to determine the amount of radiation received by the surgeon during the use of a mini-c-arm device and to compare this amount with documented measurements associated with the large c-arm device. METHODS: With use of a radiation dosimeter, measurements were carried out with tissue-equivalent anthropomorphic phantoms to quantitatively determine exposure rates at various locations and distances from the mini-c-arm for two common upper and lower extremity procedures. RESULTS: Regardless of position, distance, or relative duration of exposure, exposure rates resulting from the use of the mini-c-arm device were one to two orders of magnitude lower than those reported in the literature in association with the use of the large c-arm device. CONCLUSIONS: The mini-c-arm device should be utilized whenever feasible in order to eliminate many of the concerns associated with use of the large c-arm device, specifically those related to cumulative radiation hazards, positioning considerations, relative distance from the beam, and the need for protective shielding.


Assuntos
Fluoroscopia/instrumentação , Exposição Ocupacional/efeitos adversos , Ortopedia , Lesões por Radiação/prevenção & controle , Radiografia/instrumentação , Diagnóstico por Imagem , Humanos , Monitoramento de Radiação/instrumentação , Proteção Radiológica