Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Skin Res Technol ; 30(2): e13610, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38352988

RESUMO

BACKGROUND: Permeation-enhancing compounding bases are aimed to facilitate the penetration of the active pharmaceutical ingredients (APIs) across the skin barrier. OBJECTIVES: The purpose of this study was to evaluate the percutaneous absorption of radiolabeled human insulin (14 C-isototpe) when incorporated in a proprietary phospholipid base designed to deliver APIs with high molecular weights (HMW). The aim was not to claim the transdermal delivery of insulin with potential therapeutic applications in diabetes but, instead, to evaluate the ability of the compounding phospholipid base to deliver HMW drugs. METHODS: The percutaneous absorption of 14 C-insulin was determined using human torso skin and the Franz skin finite dose model. Two topical test formulations were prepared for in vitro evaluation: insulin 1% in phospholipid base (standard) and insulin 1% in phospholipid base HMW. The rate of percutaneous absorption (mean flux) and the distribution of 14 C-insulin through the skin were evaluated for both topical test formulations. A two-way ANOVA was used to determine statistical differences. RESULTS: The 14 C-insulin was distributed into the stratum corneum, epidermis and dermis. Mean flux values showed a rapid penetration upon application and the maximum flux was achieved at 30 min, followed by a slow decline. Subsequently, a slower decline was observed for the topical test formulation including the phospholipid base HMW. CONCLUSION: The phospholipid base HMW facilitates the percutaneous absorption of HMW drugs across human cadaver skin and, therefore, it may potentially be a useful option for compounding pharmacists and practitioners when considering the skin for the percutaneous delivery of large drugs.


Assuntos
Insulinas , Absorção Cutânea , Humanos , Fosfolipídeos/metabolismo , Preparações Farmacêuticas/metabolismo , Peso Molecular , Pele/metabolismo , Administração Cutânea , Insulinas/metabolismo
2.
Skin Res Technol ; 30(3): e13589, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38396354

RESUMO

BACKGROUND: Ketoprofen is a nonsteroidal anti-inflammatory drug used for the treatment of acute and chronic pain associated with inflammatory conditions. This study aims to evaluate the in vitro percutaneous absorption of ketoprofen 10% formulated in proprietary anhydrous and aqueous gels using the Franz skin finite dose model. MATERIALS AND METHODS: The anhydrous gel was initially characterized for cytotoxicity using EpiDerm skin tissue model by cell proliferation assay and Western blot analysis. The Ultra Performance Liquid Chromatography method for measuring ketoprofen was validated and the stability of ketoprofen 10% in the anhydrous gel formulation was evaluated at 5°C and 25°C for 181 days. The percutaneous absorption of ketoprofen was determined using donated human skin. The tissue sections were mounted within Franz diffusion cells. A variable finite dose of each ketoprofen formulation in either anhydrous or aqueous gel was applied to the skin sections and receptor solutions were collected at various time points. RESULTS: Cell proliferation assay showed minimal cell death when EpiDerm skin tissue was exposed to the anhydrous gel for 24 h; the levels of protein markers of cell proliferation were not affected after 17-h exposure. Ketoprofen was stable in the anhydrous gel when stored at 5°C and 25°C. When compounded in the anhydrous and aqueous gels, ketoprofen had mean flux rate of 2.22 and 2.50 µg/cm2 /h, respectively, after 48 h. The drug was distributed to the epidermis and dermis sections of the skin. Both the anhydrous and aqueous gels facilitated the percutaneous absorption of ketoprofen without statistically significant differences. CONCLUSION: The anhydrous gel can be used as a base to facilitate the transdermal delivery of ketoprofen. Although the anhydrous and aqueous gels can deliver a similar amount of ketoprofen, the anhydrous gel (water activity below 0.6) allows for extended default beyond-use-date of compounding preparations.


Assuntos
Cetoprofeno , Humanos , Cetoprofeno/química , Cetoprofeno/metabolismo , Absorção Cutânea , Pele/metabolismo , Anti-Inflamatórios não Esteroides , Administração Cutânea , Géis , Água/metabolismo
3.
Arch Dermatol Res ; 316(6): 291, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38814486

RESUMO

Progesterone is used for hormone replacement therapy through various routes of administration. This study was conducted to (a) evaluate the stability of progesterone in a proprietary anhydrous permeation-enhancing base (APEB) and the efficiency of its skin permeation, and (b) determine the appropriateness of mass spectrometry as a method of analysis for permeated progesterone. Using a proven stability-indicating ultra-performance liquid chromatographic method, the compounded hormone (100 mg progesterone/g APEB gel) was determined to be physically and chemically stable at room temperature for six months. Skin permeation analysis using the Franz skin finite dose model and mass spectrometry imaging showed an optical density of 1699 for the permeated progesterone compounded in APEB and 550 for the permeated progesterone in a water containing VBC, which is a statistically significant different (P = 0.029). The study suggests that APEB can be used as a compounding base for effective skin permeation of progesterone, and mass spectrometry is a reliable method for visualization and quantitative analysis of permeated progesterone.


Assuntos
Espectrometria de Massas , Progesterona , Absorção Cutânea , Pele , Progesterona/administração & dosagem , Progesterona/farmacocinética , Progesterona/metabolismo , Absorção Cutânea/efeitos dos fármacos , Espectrometria de Massas/métodos , Pele/metabolismo , Humanos , Administração Cutânea , Permeabilidade , Estabilidade de Medicamentos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Composição de Medicamentos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA