Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 46(8): 815-823, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37461858

RESUMO

BACKGROUND: Device complications, such as infection or lead dysfunction necessitating transvenous lead extraction (TLE) are continuously rising amongst patients with transvenous implantable-cardioverter-defibrillator (ICD). OBJECTIVES: Aim of this study was to characterize the procedural outcome and risk-factors of patients with indwelling 1- and 2-chamber ICD undergoing TLE. METHODS: We conducted a subgroup analysis of all ICD patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) database. Predictors for procedural failure and all-cause mortality were assessed. RESULTS: We identified 842 patients with an ICD undergoing TLE with the mean age of 62.8 ± 13.8 years. A total number of 1610 leads were treated with lead dysfunction (48.5%) as leading indication for extraction, followed by device-related infection (45.4%). Lead-per-patient ratio was 1.91 ± 0.88 and 60.0% of patients had dual-coil defibrillator leads. Additional extraction tools, such as mechanical rotating dilator sheaths and snares were utilized in 6.5% of cases. Overall procedural complications occurred in 4.3% with 2.0% major complications and a procedure-related mortality of 0.8%. Clinical success rate was 97.9%. All-cause in-hospital mortality was 3.4%, with sepsis being the leading cause for mortality. Multivariate analysis revealed lead-age ≥10 years (OR:5.82, 95%CI:2.1-16.6; p = .001) as independent predictor for procedural failure. Systemic infection (OR:9.57, 95%CI:2.2-42.4; p < .001) and procedural complications (OR:8.0, 95%CI:2.8-23.3; p < .001) were identified as risk factors for all-cause mortality. CONCLUSIONS: TLE is safe and efficacious in patients with 1- and 2-chamber ICD. Although lead dysfunction is the leading indication for extraction, systemic device-related infection is the main driver of all-cause mortality for ICD patients undergoing TLE.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Pessoa de Meia-Idade , Idoso , Criança , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco , Remoção de Dispositivo/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos
2.
Europace ; 24(10): 1627-1635, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35718878

RESUMO

AIMS: The GermAn Laser Lead Extraction RegistrY: GALLERY is a retrospective, national multicentre registry, investigating the safety and efficacy of laser lead extraction procedures in Germany. METHODS AND RESULTS: Twenty-four German centres that are performing laser lead extraction have participated in the registry. All patients, treated with a laser lead extraction procedure between January 2013 and March 2017, were consecutively enrolled. Safety and efficacy of laser lead extraction were investigated. A total number of 2524 consecutive patients with 6117 leads were included into the registry. 5499 leads with a median lead dwell time of 96 (62-141) months were treated. The mean number of treated leads per patient was 2.18 ± 1.02. The clinical procedural success rate was 97.86% and the complete lead removal was observed in 94.85%. Additional extraction tools were used in 6.65% of cases. The rate of procedural failure was 2.14% with lead age ≥10 years being its only predictor. The overall complication rate was 4.32%, including 2.06% major and 2.26% minor complications. Procedure-related mortality was 0.55%. Female sex and the presence of abandoned leads were predictors for procedure-related complications. The all-cause in-hospital mortality was 3.56% with systemic infection being the strongest predictor, followed by age ≥75 years and chronic kidney disease. CONCLUSION: In the GALLERY, a high success- and low procedure-related complication rates have been demonstrated. In multivariate analysis, female sex and the presence of abandoned leads were predictors for procedure-related complications, while the presence of systemic infection, age ≥75 years, and chronic kidney disease were independent predictors for all-cause mortality.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência Renal Crônica , Idoso , Criança , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Lasers de Excimer , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
3.
Thorac Cardiovasc Surg ; 64(8): 679-687, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27300106

RESUMO

Background The ongoing technical advances in development of new implantable cardioverter defibrillator (ICD) systems led some investigators to question the routine use of intraoperative defibrillation testing (DT). Therefore, we evaluated retrospectively in a multicenter study effectiveness, safety, and usefulness of intraoperative DT on unbiased large patient population. Methods Data from 4,572 consecutive patients undergoing any ICD intervention were retrospectively analyzed. Besides efficacy of DT, risk factors for DT failure were identified in a multiple logistic regression analysis. Results Overall 5,483 shock data from 4,532 patients were available. Not tested for medical reasons were 13.5%. DT-associated complications were not noted. Primary DT effectiveness was 95.8%, whereas 4.2% were ineffective. Optimization (51.6% increase of DT energy, 10.1% subcutaneous lead array (SQ array), 2% generator exchange, 4.8% lead reposition, 9.3% lead exchange, and 22.2% change of shock parameters) led to successful DT in 152 patients (96.2%). Subanalyses and logistic regression identified implantation of generator in any other position than left subpectoral, age, body mass index and left ventricular ejection fraction as independent predictors for primary DT failure. Conclusion The number of patients, including those undergoing generator exchange, system upgrade, or system revision, with inappropriate intraoperative testshock is relatively high. The results of recent prospective clinical trials can be extrapolated only on first ICD implantations with high-energy generators. For patients undergoing subcutaneous ICD implantation, right-sided implantation, patients with channelopathies and hypertrophic cardiomyopathy, as well as for procedures on already implanted ICD systems, the intraoperative DT might still be recommended.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Idoso , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Alemanha , Humanos , Cuidados Intraoperatórios , Modelos Logísticos , Teste de Materiais , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
4.
Heart Rhythm ; 20(2): 181-189, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36240993

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) has evolved as one of the most crucial treatment options for patients with cardiac device-related systemic infection (CDRSI). OBJECTIVE: The aim of this study was to characterize the procedural outcome and risk factors of patients with CDRSI undergoing TLE. METHODS: A subgroup analysis of patients with CDRSI of the GALLERY (GermAn Laser Lead Extraction RegistrY) database was performed. Predictors for complications, procedural failure, and all-cause mortality were evaluated. RESULTS: A total of 722 patients (28.6%) in the GALLERY had "systemic infection" as extraction indication. Patients with CDRSI were older (70.1 ± 12.2 years vs 67.3 ± 14.3 years; P < .001) and had more comorbidities than patients with local infections or noninfectious extraction indications. There were no differences in complete procedural success (90.6% vs 91.7%; P = .328) or major complications (2.5% vs 1.9%; P = .416) but increased procedure-related (1.4% vs 0.3%; P = .003) and all-cause in-hospital mortality (11.1% vs 0.6%; P < .001) for patients with CDRSI. Multivariate analyses revealed lead age ≥10 years as a predictor for procedural complications (odds ratio [OR] 3.23; 95% confidence interval [CI] 1.58-6.60; P = .001). Lead age ≥10 years (OR 2.57; 95% CI 1.03-6.46; P = .04) was also a predictor for procedural failure. We identified left ventricular ejection fraction <30% (OR 1.70; 95% CI 1.00-2.99; P = .049), age ≥75 years (OR 2.1; 95% CI 1.27-3.48; P = .004), chronic kidney disease (OR 1.92; 95% CI 1.17-3.14; P = .01), and overall procedural complications (OR 5.15; 95% CI 2.44-10.84; P < .001) as predictors for all-cause mortality. CONCLUSION: Patients with CDRSI undergoing TLE demonstrate an increased rate of all-cause in-hospital, as well as procedure-related mortality, despite having comparable procedural success rates. Given these data, it seems paramount to develop preventive strategies to detect and treat CDRSI in its earliest stages.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Humanos , Criança , Idoso , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Cardiopatias/etiologia , Comorbidade , Remoção de Dispositivo/efeitos adversos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
5.
J Clin Med ; 12(12)2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-37373789

RESUMO

BACKGROUND: The incidence of cardiac implantable electronic device (CIED)-related complications, as well as the prevalence of obesity, is rising worldwide. Transvenous laser lead extraction (LLE) has grown into a crucial therapeutic option for patients with CIED-related complications but the impact of obesity on LLE is not well understood. METHODS AND RESULTS: All patients (n = 2524) from the GermAn Laser Lead Extraction RegistrY (GALLERY) were stratified into five groups according to their body mass index (BMI, <18.5; 18.5-24.9; 25-29.9; 30-34.9; ≥35 kg/m2). Patients with a BMI ≥ 35.0 kg/m2 had the highest prevalence of arterial hypertension (84.2%, p < 0.001), chronic kidney disease (36.8%, p = 0.020) and diabetes mellitus (51.1%, p < 0.001). The rates for procedural minor (p = 0.684) and major complications (p = 0.498), as well as procedural success (p = 0.437), procedure-related (p = 0.533) and all-cause mortality (p = 0.333) were not different between groups. In obese patients (BMI ≥ 30 kg/m2), lead age ≥10 years was identified as a predictor of procedural failure (OR: 2.99; 95% CI: 1.06-8.45; p = 0.038). Lead age ≥10 years (OR: 3.25; 95% CI: 1,31-8.10; p = 0.011) and abandoned leads (OR: 3.08; 95% CI: 1.03-9.22; p = 0.044) were predictors of procedural complications, while patient age ≥75 years seemed protective (OR: 0.27; 95% CI: 0.08-0.93; p = 0.039). Systemic infection was the only predictor for all-cause mortality (OR: 17.68; 95% CI: 4.03-77.49; p < 0.001). CONCLUSIONS: LLE in obese patients is as safe and effective as in other weight classes, if performed in experienced high-volume centers. Systemic infection remains the main cause of in-hospital mortality in obese patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA