Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 96(18): 6922-6929, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38653330

RESUMO

We report the development and validation of an untargeted single-cell lipidomics method based on microflow chromatography coupled to a data-dependent mass spectrometry method for fragmentation-based identification of lipids. Given the absence of single-cell lipid standards, we show how the methodology should be optimized and validated using a dilute cell extract. The methodology is applied to dilute pancreatic cancer and macrophage cell extracts and standards to demonstrate the sensitivity requirements for confident assignment of lipids and classification of the cell type at the single-cell level. The method is then coupled to a system that can provide automated sampling of live, single cells into capillaries under microscope observation. This workflow retains the spatial information and morphology of cells during sampling and highlights the heterogeneity in lipid profiles observed at the single-cell level. The workflow is applied to show changes in single-cell lipid profiles as a response to oxidative stress, coinciding with expanded lipid droplets. This demonstrates that the workflow is sufficiently sensitive to observing changes in lipid profiles in response to a biological stimulus. Understanding how lipids vary in single cells will inform future research into a multitude of biological processes as lipids play important roles in structural, biophysical, energy storage, and signaling functions.


Assuntos
Lipidômica , Lipídeos , Análise de Célula Única , Lipidômica/métodos , Humanos , Lipídeos/análise , Lipídeos/química , Animais , Cromatografia Líquida , Camundongos , Linhagem Celular Tumoral , Espectrometria de Massas , Macrófagos/metabolismo , Macrófagos/citologia
2.
Mol Syst Biol ; 19(3): e11099, 2023 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-36705093

RESUMO

Metabolic flux is the final output of cellular regulation and has been extensively studied for carbon but much less is known about nitrogen, which is another important building block for living organisms. For the tuberculosis pathogen, this is particularly important in informing the development of effective drugs targeting the pathogen's metabolism. Here we performed 13 C15 N dual isotopic labeling of Mycobacterium bovis BCG steady state cultures, quantified intracellular carbon and nitrogen fluxes and inferred reaction bidirectionalities. This was achieved by model scope extension and refinement, implemented in a multi-atom transition model, within the statistical framework of Bayesian model averaging (BMA). Using BMA-based 13 C15 N-metabolic flux analysis, we jointly resolve carbon and nitrogen fluxes quantitatively. We provide the first nitrogen flux distributions for amino acid and nucleotide biosynthesis in mycobacteria and establish glutamate as the central node for nitrogen metabolism. We improved resolution of the notoriously elusive anaplerotic node in central carbon metabolism and revealed possible operation modes. Our study provides a powerful and statistically rigorous platform to simultaneously infer carbon and nitrogen metabolism in any biological system.


Assuntos
Carbono , Nitrogênio , Carbono/metabolismo , Isótopos de Carbono/metabolismo , Nitrogênio/metabolismo , Análise do Fluxo Metabólico , Teorema de Bayes , Modelos Biológicos
3.
Anal Chem ; 95(39): 14727-14735, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37725657

RESUMO

In this work, we demonstrate the development and first application of nanocapillary sampling followed by analytical flow liquid chromatography-mass spectrometry for single-cell lipidomics. Around 260 lipids were tentatively identified in a single cell, demonstrating remarkable sensitivity. Human pancreatic ductal adenocarcinoma cells (PANC-1) treated with the chemotherapeutic drug gemcitabine can be distinguished from controls solely on the basis of their single-cell lipid profiles. Notably, the relative abundance of LPC(0:0/16:0) was significantly affected in gemcitabine-treated cells, in agreement with previous work in bulk. This work serves as a proof of concept that live cells can be sampled selectively and then characterized using automated and widely available analytical workflows, providing biologically relevant outputs.


Assuntos
Lipidômica , Neoplasias Pancreáticas , Humanos , Cromatografia Líquida , Lipidômica/métodos , Lipídeos/análise , Espectrometria de Massas em Tandem , Neoplasias Pancreáticas/tratamento farmacológico , Gencitabina , Neoplasias Pancreáticas
4.
Analyst ; 148(5): 1041-1049, 2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36723178

RESUMO

This work describes the development of a new approach to measure drug levels and lipid fingerprints in single living mammalian cells. Nanocapillary sampling is an approach that enables the selection and isolation of single living cells under microscope observation. Here, live single cell nanocapillary sampling is coupled to liquid chromatography for the first time. This allows molecular species to be separated prior to ionisation and improves measurement precision of drug analytes. The efficiency of transferring analytes from the sampling capillary into a vial was optimised in this work. The analysis was carried out using standard flow liquid chromatography coupled to widely available mass spectrometry instrumentation, highlighting opportunities for widespread adoption. The method was applied to 30 living cells, revealing cell-to-cell heterogeneity in the uptake of different drug molecules. Using this system, we detected 14-158 lipid features per single cell, revealing the association between bedaquiline uptake and lipid fingerprints.


Assuntos
Lipídeos , Mamíferos , Animais , Espectrometria de Massas/métodos , Cromatografia Líquida/métodos
5.
Int J Mol Sci ; 24(18)2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37762673

RESUMO

The global COVID-19 pandemic resulted in widespread harms but also rapid advances in vaccine development, diagnostic testing, and treatment. As the disease moves to endemic status, the need to identify characteristic biomarkers of the disease for diagnostics or therapeutics has lessened, but lessons can still be learned to inform biomarker research in dealing with future pathogens. In this work, we test five sets of research-derived biomarkers against an independent targeted and quantitative Liquid Chromatography-Mass Spectrometry metabolomics dataset to evaluate how robustly these proposed panels would distinguish between COVID-19-positive and negative patients in a hospital setting. We further evaluate a crowdsourced panel comprising the COVID-19 metabolomics biomarkers most commonly mentioned in the literature between 2020 and 2023. The best-performing panel in the independent dataset-measured by F1 score (0.76) and AUROC (0.77)-included nine biomarkers: lactic acid, glutamate, aspartate, phenylalanine, ß-alanine, ornithine, arachidonic acid, choline, and hypoxanthine. Panels comprising fewer metabolites performed less well, showing weaker statistical significance in the independent cohort than originally reported in their respective discovery studies. Whilst the studies reviewed here were small and may be subject to confounders, it is desirable that biomarker panels be resilient across cohorts if they are to find use in the clinic, highlighting the importance of assessing the robustness and reproducibility of metabolomics analyses in independent populations.


Assuntos
COVID-19 , Pandemias , Humanos , Reprodutibilidade dos Testes , COVID-19/diagnóstico , Metabolômica/métodos , Biomarcadores/metabolismo
6.
Molecules ; 28(15)2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37570657

RESUMO

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has been shown to enhance fingermark recovery compared to standard processes used by police forces, but there is no data to show how generally applicable the improvement is. Additionally, ToF-SIMS can be run in either positive or negative ion mode (or both), and there is no data on which mode of operation is most effective at revealing fingerprints. This study aims to fill these gaps by using ToF-SIMS to image fingerprints deposited on two common exhibit-type surfaces (polyethylene and stainless steel) using 10 donors and ageing fingerprints in either ambient, rainwater, or underground for 1 and 5 months. In all, 120 fingerprints were imaged using ToF-SIMS, and each was run in positive and negative modes. A fingerprint expert compared the fingerprint ridge detail produced by the standard process to the ToF-SIMS images. In over 50% of the samples, ToF-SIMS was shown to improve fingerprint ridge detail visualised by the respective standard process for all surfaces tested. In over 90% of the samples, the ridge detail produced by ToF-SIMS was equivalent to standard development across all different ageing and exposure conditions. The data shows that there is a benefit to running the ToF-SIMS in both positive and negative modes, even if no ridge detail was seen in one mode.

7.
Anal Chem ; 94(34): 11798-11806, 2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-35981335

RESUMO

Elemental imaging is widely used for imaging cells and tissues but rarely in combination with organic mass spectrometry, which can be used to profile lipids and measure drug concentrations. Here, we demonstrate how elemental imaging and a new method for spatially resolved lipidomics (DAPNe-LC-MS, based on capillary microsampling and liquid chromatography mass spectrometry) can be used in combination to probe the relationship between metals, drugs, and lipids in discrete areas of tissues. This new method for spatial lipidomics, reported here for the first time, has been applied to rabbit lung tissues containing a lesion (caseous granuloma) caused by tuberculosis infection. We demonstrate how elemental imaging with spatially resolved lipidomics can be used to probe the association between ion accumulation and lipid profiles and verify local drug distribution.


Assuntos
Lipidômica , Lipídeos , Animais , Biomarcadores , Cromatografia Líquida/métodos , Lipídeos/análise , Espectrometria de Massas/métodos , Coelhos
8.
Int J Mol Sci ; 23(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36292938

RESUMO

Treatments for COVID-19 infections have improved dramatically since the beginning of the pandemic, and glucocorticoids have been a key tool in improving mortality rates. The UK's National Institute for Health and Care Excellence guidance is for treatment to be targeted only at those requiring oxygen supplementation, however, and the interactions between glucocorticoids and COVID-19 are not completely understood. In this work, a multi-omic analysis of 98 inpatient-recruited participants was performed by quantitative metabolomics (using targeted liquid chromatography-mass spectrometry) and data-independent acquisition proteomics. Both 'omics datasets were analysed for statistically significant features and pathways differentiating participants whose treatment regimens did or did not include glucocorticoids. Metabolomic differences in glucocorticoid-treated patients included the modulation of cortisol and bile acid concentrations in serum, but no alleviation of serum dyslipidemia or increased amino acid concentrations (including tyrosine and arginine) in the glucocorticoid-treated cohort relative to the untreated cohort. Proteomic pathway analysis indicated neutrophil and platelet degranulation as influenced by glucocorticoid treatment. These results are in keeping with the key role of platelet-associated pathways and neutrophils in COVID-19 pathogenesis and provide opportunity for further understanding of glucocorticoid action. The findings also, however, highlight that glucocorticoids are not fully effective across the wide range of 'omics dysregulation caused by COVID-19 infections.


Assuntos
Tratamento Farmacológico da COVID-19 , Glucocorticoides , Humanos , Glucocorticoides/farmacologia , Glucocorticoides/uso terapêutico , Proteômica/métodos , Hidrocortisona , Metabolômica/métodos , Aminoácidos/metabolismo , Tirosina , Arginina , Ácidos e Sais Biliares
9.
Anal Chem ; 93(40): 13450-13458, 2021 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-34597513

RESUMO

Elemental and molecular imaging play a crucial role in understanding disease pathogenesis. To accurately correlate elemental and molecular markers, it is desirable to perform sequential elemental and molecular imaging on a single-tissue section. However, very little is known about the impact of performing these measurements in sequence. In this work, we highlight some of the challenges and successes associated with performing elemental mapping in sequence with mass spectrometry imaging. Specifically, the feasibility of molecular mapping using the mass spectrometry imaging (MSI) techniques matrix-assisted laser desorption ionization (MALDI) and desorption electrospray ionization (DESI) in sequence with the elemental mapping technique particle-induced X-ray emission (PIXE) is explored. Challenges for integration include substrate compatibility, as well as delocalization and spectral changes. We demonstrate that while sequential imaging comes with some compromises, sequential DESI-PIXE imaging is sufficient to correlate sulfur, iron, and lipid markers in a single tissue section at the 50 µm scale.


Assuntos
Oligoelementos , Lipídeos , Imagem Molecular , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Enxofre
10.
Anal Chem ; 92(14): 9847-9855, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32545955

RESUMO

The use of a low aerosol dispersion ablation chamber within a laser ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) setup allows for high-resolution, high-speed imaging of the distribution of elements within a sample. Here we show how this enhanced capability creates new analytical problems and solutions. We report the distribution of platinum at the cellular level in non-small cell lung cancer (NSCLC) explant models after treatment with clinically relevant doses of cisplatin. This revealed for the first time a correlation between the platinum signal and the presence of carbon deposits within lung tissue. We show how complementary ion beam analysis techniques, particle-induced X-ray emission (PIXE) and elastic backscattering spectrometry (EBS), can be used to explore potential matrix effects in LA-ICP-MS data. For these samples, it was confirmed that the enhancement was unlikely to have resulted from a matrix effect alone. Thus, the presence of carbon deposits within tissue has potential implications for the effective distribution of the cisplatin drug.


Assuntos
Cisplatino/uso terapêutico , Neoplasias Pulmonares/química , Neoplasias Pulmonares/tratamento farmacológico , Espectrometria de Massas/métodos , Antineoplásicos/uso terapêutico , Carbono/química , Carcinoma Pulmonar de Células não Pequenas , Humanos , Terapia a Laser , Esferoides Celulares , Técnicas de Cultura de Tecidos
11.
Analyst ; 145(8): 3038-3048, 2020 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-32134419

RESUMO

The use of synthetic stimulants, including designer cathinones, remains a significant concern worldwide. Thus, the detection and identification of synthetic cathinones in biological matrices is of paramount importance for clinical and forensic laboratories. In this study, distribution of mephedrone and its metabolites was investigated in fingerprints. Following a controlled human mephedrone administration (100 mg nasally insufflated), two mass spectrometry-based methods for fingerprint analysis have been evaluated. The samples deposited on triangular pieces of chromatography paper were directly analysed under ambient conditions by paper spray-mass spectrometry (PS-MS) while those deposited on glass cover slips were extracted and analysed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The LC-MS/MS method was 5-6 times more sensitive than PS-MS but required sample preparation and longer analysis time. Mephedrone was detected in 62% and in 38% of all post-administration samples analysed by LC-MS/MS and PS-MS, respectively. Nor-mephedrone was the only metabolite detected in 3.8% of all samples analysed by LC-MS/MS. A large inter- and intra-subject variation was observed for mephedrone which may be due to several factors, such as the applied finger pressure, angle and duration of contact with the deposition surface and inability to control the 'amount' of collected fingerprint deposits. Until these limitations are addressed, we suggest that the sole use of fingerprints can be a useful diagnostic tool in qualitative rather than quantitative analysis, and requires a confirmatory analysis in a different biological matrix.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Cromatografia Líquida de Alta Pressão/métodos , Dermatoglifia , Metanfetamina/análogos & derivados , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos , Administração por Inalação , Estimulantes do Sistema Nervoso Central/administração & dosagem , Estimulantes do Sistema Nervoso Central/metabolismo , Humanos , Masculino , Metanfetamina/administração & dosagem , Metanfetamina/análise , Metanfetamina/metabolismo , Papel , Espectrometria de Massas em Tandem/instrumentação
12.
Anal Chem ; 91(24): 15411-15417, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31747247

RESUMO

Direct analyte-probed nanoextraction (DAPNe) is a technique that allows extraction of drug and endogenous compounds from a discrete location on a tissue sample using a nano capillary filled with solvent. Samples can be extracted from spot diameters as low as 6 µm. Studies previously undertaken by our group have shown that the technique can provide good precision (5%) for analyzing drug molecules in 150 µm diameter areas of homogenized tissue, provided an internal standard is sprayed on to the tissue prior to analysis. However, without an isotopically labeled standard, the repeatability is poor, even after normalization to the spot area or matrix compounds. By application to tissue homogenates spiked with drug compounds, we can demonstrate that it is possible to significantly improve the repeatability of the technique by incorporating a liquid chromatography separation step. Liquid chromatography is a technique for separating compounds prior to mass spectrometry (LC-MS) which enables separation of isomeric compounds that cannot be discriminated using mass spectrometry alone, as well as reducing matrix interferences. Conventionally, LC-MS is carried out on bulk or homogenized samples, which means analysis is essentially an average of the sample and does not take into account discrete areas. This work opens a new opportunity for spatially resolved liquid chromatography mass spectrometry with precision better than 20%.

13.
Artigo em Inglês | MEDLINE | ID: mdl-31414505

RESUMO

RATIONALE: Paper spray offers a rapid screening test without the need for sample preparation. The incomplete extraction of paper spray allows for further testing using more robust, selective and sensitive techniques such as liquid chromatography/mass spectrometry (LC/MS). Here we develop a two-step process of paper spray followed by LC/MS to (1) rapidly screen a large number of samples and (2) confirm any disputed results. This demonstrates the applicability for testing medication adherence from a fingerprint. METHODS: Following paper spray analysis, drugs of abuse samples were analysed using LC/MS. All analyses were completed using a Q Exactive™ Plus Orbitrap™ mass spectrometer. This two-step procedure was applied to fingerprints collected from patients on a maintained dose of the antipsychotic drug quetiapine. RESULTS: The extraction efficiency of paper spray for two drugs of abuse and metabolites was found to be between 15 and 35% (analyte dependent). For short acquisition times, the extraction efficiency was found to vary between replicates by less than 30%, enabling subsequent analysis by LC/MS. This two-step process was then applied to fingerprints collected from two patients taking the antipsychotic drug quetiapine, which demonstrates how a negative screening result from paper spray can be resolved using LC/MS. CONCLUSIONS: We have shown for the first time the sequential analysis of the same sample using paper spray and LC/MS, as well as the detection of an antipsychotic drug from a fingerprint. We propose that this workflow may also be applied to any type of sample compatible with paper spray, and will be especially convenient where only one sample is available for analysis.

14.
Sci Justice ; 59(2): 181-189, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30798867

RESUMO

Gunshot Residue (GSR) produced by the discharge of a firearm often provides very useful information in criminal investigations in cases involving the use of firearms. Scanning Electron Microscopy equipped with an Energy Dispersive X-ray Spectrometer (SEM-EDS) is typically used worldwide to visualize micrometric particles constituting GSR and to analyse their elemental composition. The 2017 ASTM Standard guide for gunshot residue analysis by scanning electron microscopy/energy dispersive X-ray spectroscopy specifies that "Particles classified as characteristic of GSR will have one of the following elemental compositions: Lead, antimony, barium; Lead, barium, calcium, silicon, tin". For the first time, the presence of an additional element, such as Sn, plays a key role in ASTM particle classification. It is known that some ammunitions, used for pistols, revolvers and rifles, contain tin foil discs for sealing the primer mixture into the cup, resulting in GSR particles containing Sn. The authors faced some cases in which Sn was unexpectedly found in GSR particles from a 0.22 Long Rifle derringer and from some 12 gauge shotguns. No tin foil discs are used in rimfire ammunitions and there is no published evidence of tin foil discs in shotshell ammunitions. Following a "case by case" approach, experimental research has been carried out to explain how Sn can be present in GSR particles when the last discharged cartridge also does not contain any Sn either in components and in the explosive charges. Moreover, the use of Particle Induced X-ray Emission (PIXE) showed the capability to overcome overlap ambiguity of Sb and Sn peaks in the X-ray spectra, being a possible key issue in real shooting cases if Sn quantities are below the lower limit of SEM detection, especially when Sb is also present.

15.
Anal Chem ; 90(20): 12094-12100, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30260213

RESUMO

Direct analyte probed nanoextraction (DAPNe) is a method of extracting material from a microscale region of a sample and provides the opportunity for detailed mass spectrometry analysis of extracted analytes from a small area. The technique has been shown to provide enhanced sensitivity compared with bulk analysis by selectively removing analytes from their matrix and has been applied for selective analysis of single cells and even single organelles. However, the quantitative capabilities of the technique are yet to be fully evaluated. In this study, various normalization techniques were investigated in order to improve the quantitative capabilities of the technique. Two methods of internal standard incorporation were applied to test substrates, which were designed to replicate biological sample matrices. Additionally, normalization to the extraction spot area and matrix compounds were investigated for suitability in situations when an internal standard is not available. The variability observed can be significantly reduced by using a sprayed internal standard and, in some cases, by normalizing to the extracted area.


Assuntos
Fígado/citologia , Nanotecnologia , Análise de Célula Única , Humanos , Espectrometria de Massas , Organelas/química
16.
Clin Chem ; 63(11): 1745-1752, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28939761

RESUMO

BACKGROUND: Paper spray mass spectrometry (PS-MS) is a technique that has recently emerged and has shown excellent analytical sensitivity to a number of drugs in blood. As an alternative to blood, fingerprints have been shown to provide a noninvasive and traceable sampling matrix. Our goal was to validate the use of fingerprint samples to detect cocaine use. METHODS: Samples were collected on triangular pieces (168 mm2) of washed Whatman Grade I chromatography paper. Following application of internal standard, spray solvent and a voltage were applied to the paper before mass spectrometry detection. A fingerprint visualization step was incorporated into the analysis procedure by addition of silver nitrate solution and exposing the sample to ultraviolet light. RESULTS: Limits of detection for cocaine, benzoylecgonine, and methylecgonine were 1, 2, and 31 ng/mL respectively, with relative standard deviations < 33%. No matrix effects were observed. Analysis of 239 fingerprint samples yielded a 99% true-positive rate and a 2.5% false-positive rate, based on the detection of cocaine, benzoylecgonine, or methylecgonine with use of a single fingerprint. CONCLUSIONS: The method offers a qualitative and noninvasive screening test for cocaine use. The analysis method developed is rapid (4 min/sample) and requires no sample preparation.


Assuntos
Cocaína/análogos & derivados , Cocaína/análise , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Dermatoglifia , Humanos , Limite de Detecção , Papel , Saliva/química , Suor/química
17.
Analyst ; 140(18): 6254-9, 2015 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-25977942

RESUMO

Latent fingerprints provide a potential route to the secure, high throughput and non-invasive detection of drugs of abuse. In this study we show for the first time that the excreted metabolites of drugs of abuse can be detected in fingerprints using ambient mass spectrometry. Fingerprints and oral fluid were taken from patients attending a drug and alcohol treatment service. Gas chromatography mass spectrometry (GC-MS) was used to test the oral fluid of patients for the presence of cocaine and benzoylecgonine. The corresponding fingerprints were analysed using Desorption Electrospray Ionization (DESI) which operates under ambient conditions and Ion Mobility Tandem Mass Spectrometry Matrix Assisted Laser Desorption Ionization (MALDI-IMS-MS/MS) and Secondary Ion Mass Spectrometry (SIMS). The detection of cocaine, benzoylecgonine (BZE) and methylecgonine (EME) in latent fingerprints using both DESI and MALDI showed good correlation with oral fluid testing. The sensitivity of SIMS was found to be insufficient for this application. These results provide exciting opportunities for the use of fingerprints as a new sampling medium for secure, non-invasive drug detection. The mass spectrometry techniques used here offer a high level of selectivity and consume only a small area of a single fingerprint, allowing repeat and high throughput analyses of a single sample.


Assuntos
Cocaína/análogos & derivados , Cocaína/análise , Dermatoglifia , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Pressão Atmosférica , Humanos , Propriedades de Superfície , Fatores de Tempo
18.
Analyst ; 138(16): 4649-55, 2013 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-23775063

RESUMO

Imaging and analyzing gunshot residue (GSR) particles using the scanning electron microscope equipped with an energy dispersive X-ray spectrometer (SEM-EDS) is a standard technique that can provide important forensic evidence, but the discrimination power of this technique is limited due to low sensitivity to trace elements and difficulties in obtaining quantitative results from small particles. A new, faster method using a scanning proton microbeam and Particle Induced X-ray Emission (µ-PIXE), together with Elastic Backscattering Spectrometry (EBS) is presented for the non-destructive, quantitative analysis of the elemental composition of single GSR particles. In this study, the GSR particles were all Pb, Ba, Sb. The precision of the method is assessed. The grouping behaviour of different makes of ammunition is determined using multivariate analysis. The protocol correctly groups the cartridges studied here, with a confidence >99%, irrespective of the firearm or population of particles selected.


Assuntos
Armas de Fogo , Medicina Legal/métodos , Espectrometria por Raios X/métodos , Ferimentos por Arma de Fogo , Medicina Legal/normas , Humanos , Microscopia Eletrônica de Varredura/métodos , Microscopia Eletrônica de Varredura/normas , Espectrometria por Raios X/normas
19.
Sci Justice ; 63(1): 9-18, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36631186

RESUMO

The processes routinely used by police forces to visualise fingermarks in casework may not provide sufficient ridge pattern quality to aid an investigation. Time of Flight-Secondary Ion Mass Spectrometry (ToF-SIMS) has been proposed as a technique to enhance fingermark recovery. The technique is currently designated a Category C process in the Fingermark Visualisation Manual (FVM) as it shows potential for effective fingermark visualisation but has not yet been fully evaluated. Here the sensitivity of ToF-SIMS on three common exhibit-type surfaces - paper, polyethylene and stainless-steel was compared to standard processes. An adapted Home Office grading scale was used to evaluate the efficacy of fingerprint development by ToF-SIMS and to provide a framework for comparison with standard processes. ToF-SIMS was shown to visualise more fingerprints than the respective standard process, for all surfaces tested. In addition, ToF-SIMS was applied after the standard processes and successfully enhanced the fingerprint detail, even when the standard process failed to visualise ridge detail. This demonstrates the benefit for incorporating it into current operational fingermark development workflows. Multivariate analysis (MVA), using simsMVA, was additionally explored as a method to simplify the data analysis and image generation process.


Assuntos
Dermatoglifia , Espectrometria de Massa de Íon Secundário , Humanos , Espectrometria de Massa de Íon Secundário/métodos , Polícia , Análise Multivariada
20.
Curr Opin Chem Biol ; 75: 102327, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37224735

RESUMO

Single cell metabolomics is a rapidly advancing field of bio-analytical chemistry which aims to observe cellular biology with the greatest detail possible. Mass spectrometry imaging and selective cell sampling (e.g. using nanocapillaries) are two common approaches within the field. Recent achievements such as observation of cell-cell interactions, lipids determining cell states and rapid phenotypic identification demonstrate the efficacy of these approaches and the momentum of the field. However, single cell metabolomics can only continue with the same impetus if the universal challenges to the field are met, such as the lack of strategies for standardisation and quantification, and lack of specificity/sensitivity. Mass spectrometry imaging and selective cell sampling come with unique advantages and challenges which, in many cases are complementary to each other. We propose here that the challenges specific to each approach could be ameliorated with collaboration between the two communities driving these approaches.


Assuntos
Lipídeos , Metabolômica , Lipídeos/química , Metabolômica/métodos , Espectrometria de Massas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA