Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Nanobiotechnology ; 21(1): 133, 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-37095500

RESUMO

Nanotechnology-enabled sensors or nanosensors are emerging as promising new tools for various in-vivo life science applications such as biosensing, components of delivery systems, and probes for spatial bioimaging. However, as with a wide range of synthetic biomaterials, tissue responses have been observed depending on cell types and various nanocomponent properties. The tissue response is critical for determining the acute and long term health of the organism and the functional lifetime of the material in-vivo. While nanomaterial properties can contribute significantly to the tissue response, it may be possible to circumvent adverse reactions by formulation of the encapsulation vehicle. In this study, five formulations of poly (ethylene glycol) diacrylate (PEGDA) hydrogel-encapsulated fluorescent nanosensors were implanted into SKH-1E mice, and the inflammatory responses were tracked in order to determine the favorable design rules for hydrogel encapsulation and minimization of such responses. Hydrogels with higher crosslinking density were found to allow faster resolution of acute inflammation. Five different immunocompromised mice lines were utilized for comparison across different inflammatory cell populations and responses. Degradation products of the gels were also characterized. Finally, the importance of the tissue response in determining functional lifetime was demonstrated by measuring the time-dependent nanosensor deactivation following implantation into animal models.


Assuntos
Hidrogéis , Polietilenoglicóis , Camundongos , Animais , Inflamação/induzido quimicamente , Materiais Biocompatíveis
2.
Small ; 17(31): e2100540, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34176216

RESUMO

Vitamins such as riboflavin and ascorbic acid are frequently utilized in a range of biomedical applications as drug delivery targets, fluidic tracers, and pharmaceutical excipients. Sensing these biochemicals in the human body has the potential to significantly advance medical research and clinical applications. In this work, a nanosensor platform consisting of single-walled carbon nanotubes (SWCNTs) with nanoparticle corona phases engineered to allow for the selective molecular recognition of ascorbic acid and riboflavin, is developed. The study provides a methodological framework for the implementation of colloidal SWCNT nanosensors in an intraperitoneal SKH1-E murine model by addressing complications arising from tissue absorption and scattering, mechanical perturbations, as well as sensor diffusion and interactions with the biological environment. Nanosensors are encapsulated in a polyethylene glycol diacrylate hydrogel and a diffusion model is utilized to validate analyte transport and sensor responses to local concentrations at the boundary. Results are found to be reproducible and stable after exposure to 10% mouse serum even after three days of in vivo implantation. A geometrical encoding scheme is used to reference sensor pairs, correcting for in vivo optical and mechanical artifacts, resulting in an order of magnitude improvement of p-value from 0.084 to 0.003 during analyte sensing.


Assuntos
Nanopartículas , Nanotubos de Carbono , Animais , Corantes , Camundongos , Vitaminas
3.
ACS Nano ; 17(1): 240-250, 2023 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-36524700

RESUMO

There is a pressing need for sensors and assays to monitor chemotherapeutic activity within the human body in real time to optimize drug dosimetry parameters such as timing, quantity, and frequency in an effort to maximize efficacy while minimizing deleterious cytotoxicity. Herein, we develop near-infrared fluorescent nanosensors based on single walled carbon nanotubes for the chemotherapeutic Temozolomide (TMZ) and its metabolite 5-aminoimidazole-4-carboxamide using Corona Phase Molecular Recognition as a synthetic molecular recognition technique. The resulting nanoparticle sensors are able to monitor drug activity in real-time even under in vivo conditions. Sensors can be engineered to be biocompatible by encapsulation in poly(ethylene glycol) diacrylate hydrogels. Selective detection of TMZ was demonstrated using U-87 MG human glioblastoma cells and SKH-1E mice with detection limits below 30 µM. As sensor implants, we show that such systems can provide spatiotemporal therapeutic information in vivo, as a valuable tool for pharmacokinetic evaluation. Sensor implants are also evaluated using intact porcine brain tissue implanted 2.1 cm below the cranium and monitored using a recently developed Wavelength-Induced Frequency Filtering technique. Additionally, we show that by taking the measurement of spatial and temporal analyte concentrations within each hydrogel implant, the direction of therapeutic flux can be resolved. In all, these types of sensors enable the real time detection of chemotherapeutic concentration, flux, directional transport, and metabolic activity, providing crucial information regarding therapeutic effectiveness.


Assuntos
Glioblastoma , Nanotubos de Carbono , Humanos , Animais , Camundongos , Suínos , Temozolomida , Glioblastoma/tratamento farmacológico , Corantes
4.
ACS Pharmacol Transl Sci ; 6(10): 1382-1395, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37854621

RESUMO

The glucose-responsive insulin (GRI) MK-2640 from Merck was a pioneer in its class to enter the clinical stage, having demonstrated promising responsiveness in in vitro and preclinical studies via a novel competitive clearance mechanism (CCM). The smaller pharmacokinetic response in humans motivates the development of new predictive, computational tools that can improve the design of therapeutics such as GRIs. Herein, we develop and use a new computational model, IM3PACT, based on the intersection of human and animal model glucoregulatory systems, to investigate the clinical translatability of CCM GRIs based on existing preclinical and clinical data of MK-2640 and regular human insulin (RHI). Simulated multi-glycemic clamps not only validated the earlier hypothesis of insufficient glucose-responsive clearance capacity in humans but also uncovered an equally important mismatch between the in vivo competitiveness profile and the physiological glycemic range, which was not observed in animals. Removing the inter-species gap increases the glucose-dependent GRI clearance from 13.0% to beyond 20% for humans and up to 33.3% when both factors were corrected. The intrinsic clearance rate, potency, and distribution volume did not apparently compromise the translation. The analysis also confirms a responsive pharmacokinetics local to the liver. By scanning a large design space for CCM GRIs, we found that the mannose receptor physiology in humans remains limiting even for the most optimally designed candidate. Overall, we show that this computational approach is able to extract quantitative and mechanistic information of value from a posteriori analysis of preclinical and clinical data to assist future therapeutic discovery and development.

5.
Nat Nanotechnol ; 17(6): 643-652, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35637357

RESUMO

Fluorescent nanosensors hold the potential to revolutionize life sciences and medicine. However, their adaptation and translation into the in vivo environment is fundamentally hampered by unfavourable tissue scattering and intrinsic autofluorescence. Here we develop wavelength-induced frequency filtering (WIFF) whereby the fluorescence excitation wavelength is modulated across the absorption peak of a nanosensor, allowing the emission signal to be separated from the autofluorescence background, increasing the desired signal relative to noise, and internally referencing it to protect against artefacts. Using highly scattering phantom tissues, an SKH1-E mouse model and other complex tissue types, we show that WIFF improves the nanosensor signal-to-noise ratio across the visible and near-infrared spectra up to 52-fold. This improvement enables the ability to track fluorescent carbon nanotube sensor responses to riboflavin, ascorbic acid, hydrogen peroxide and a chemotherapeutic drug metabolite for depths up to 5.5 ± 0.1 cm when excited at 730 nm and emitting between 1,100 and 1,300 nm, even allowing the monitoring of riboflavin diffusion in thick tissue. As an application, nanosensors aided by WIFF detect the chemotherapeutic activity of temozolomide transcranially at 2.4 ± 0.1 cm through the porcine brain without the use of fibre optic or cranial window insertion. The ability of nanosensors to monitor previously inaccessible in vivo environments will be important for life-sciences research, therapeutics and medical diagnostics.


Assuntos
Nanotubos de Carbono , Animais , Fluorescência , Corantes Fluorescentes , Peróxido de Hidrogênio , Camundongos , Riboflavina , Suínos
6.
Diabetes ; 69(8): 1815-1826, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32152206

RESUMO

Despite considerable progress, development of glucose-responsive insulins (GRIs) still largely depends on empirical knowledge and tedious experimentation-especially on rodents. To assist the rational design and clinical translation of the therapeutic, we present a Pharmacokinetic Algorithm Mapping GRI Efficacies in Rodents and Humans (PAMERAH) built upon our previous human model. PAMERAH constitutes a framework for predicting the therapeutic efficacy of a GRI candidate from its user-specified mechanism of action, kinetics, and dosage, which we show is accurate when checked against data from experiments and literature. Results from simulated glucose clamps also agree quantitatively with recent GRI publications. We demonstrate that the model can be used to explore the vast number of permutations constituting the GRI parameter space and thereby identify the optimal design ranges that yield desired performance. A design guide aside, PAMERAH more importantly can facilitate GRI's clinical translation by connecting each candidate's efficacies in rats, mice, and humans. The resultant mapping helps to find GRIs that appear promising in rodents but underperform in humans (i.e., false positives). Conversely, it also allows for the discovery of optimal human GRI dynamics not captured by experiments on a rodent population (false negatives). We condense such information onto a "translatability grid" as a straightforward, visual guide for GRI development.


Assuntos
Hipoglicemiantes/farmacocinética , Insulina/farmacocinética , Algoritmos , Animais , Técnica Clamp de Glucose , Humanos , Camundongos , Ratos
7.
ACS Sens ; 3(2): 367-377, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-29359558

RESUMO

Corona phase molecular recognition (CoPhMoRe) is a technique whereby an external, adsorbed phase around a colloidal nanoparticle is selected such that its molecular conformation or interaction recognizes a specific target analyte. In this work, we employ a high-throughput screening of a library of poly(ethylene glycol) (PEG)-conjugated lipids adsorbed onto near-infrared fluorescent single-walled carbon nanotubes to discover a corona phase selective for insulin. We find that a C16-PEG(2000 Da)-ceramide causes a 62% fluorescent intensity decrease of the (10,2) chirality nanotube in the presence of 20 µg/mL insulin. The insulin protein has no prior affinity toward the C16-PEG(2000 Da)-ceramide molecules in free solution, verified by isothermal titration calorimetry, and the interaction occurs only upon their adsorption onto the single-walled carbon nanotube scaffolds. Testing a panel of proteins originating from human blood as well as short 7 amino acid fragments of the insulin peptide rules out nonselective recognition mechanisms such as molecular weight, isoelectric point, and hydrophobicity-based detection. Interestingly, longer fragments of isolated α- and ß-peptide chains of insulin are detected by the construct, albeit with lower affinity compared to that of the intact insulin protein, suggesting that the construct recognizes insulin in its native form and conformation. Finally, the insulin recognition and the quantification of its solution concentration were demonstrated both in buffer and in blood serum, showing that the CoPhMoRe construct works in this complex environment despite the presence of potential nonspecific adsorption. Our results further motivate the search for nonbiological synthetic recognition sites and open up a new path for continuous insulin monitoring in vivo with the hope of improving glycemic control in closed-loop artificial pancreas systems.


Assuntos
Técnicas Biossensoriais/métodos , Proteínas Sanguíneas/química , Insulina/sangue , Nanotubos de Carbono/química , Coroa de Proteína/química , Técnicas Biossensoriais/instrumentação , Calibragem , Ceramidas/química , Corantes Fluorescentes/química , Polietilenoglicóis/química , Ligação Proteica
8.
Adv Healthc Mater ; 6(22)2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28841775

RESUMO

A glucose responsive insulin (GRI) is a therapeutic that modulates its potency, concentration, or dosing of insulin in relation to a patient's dynamic glucose concentration, thereby approximating aspects of a normally functioning pancreas. Current GRI design lacks a theoretical basis on which to base fundamental design parameters such as glucose reactivity, dissociation constant or potency, and in vivo efficacy. In this work, an approach to mathematically model the relevant parameter space for effective GRIs is induced, and design rules for linking GRI performance to therapeutic benefit are developed. Well-developed pharmacokinetic models of human glucose and insulin metabolism coupled to a kinetic model representation of a freely circulating GRI are used to determine the desired kinetic parameters and dosing for optimal glycemic control. The model examines a subcutaneous dose of GRI with kinetic parameters in an optimal range that results in successful glycemic control within prescribed constraints over a 24 h period. Additionally, it is demonstrated that the modeling approach can find GRI parameters that enable stable glucose levels that persist through a skipped meal. The results provide a framework for exploring the parameter space of GRIs, potentially without extensive, iterative in vivo animal testing.


Assuntos
Glucose/metabolismo , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/farmacocinética , Insulina/administração & dosagem , Insulina/farmacocinética , Animais , Glicemia/efeitos dos fármacos , Humanos , Cinética , Modelos Teóricos
9.
Nat Chem ; 9(10): 937-943, 2017 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-28937662

RESUMO

The concept of a glucose-responsive insulin (GRI) has been a recent objective of diabetes technology. The idea behind the GRI is to create a therapeutic that modulates its potency, concentration or dosing relative to a patient's dynamic glucose concentration, thereby approximating aspects of a normally functioning pancreas. From the perspective of the medicinal chemist, the GRI is also important as a generalized model of a potentially new generation of therapeutics that adjust potency in response to a critical therapeutic marker. The aim of this Perspective is to highlight emerging concepts, including mathematical modelling and the molecular engineering of insulin itself and its potency, towards a viable GRI. We briefly outline some of the most important recent progress toward this goal and also provide a forward-looking viewpoint, which asks if there are new approaches that could spur innovation in this area as well as to encourage synthetic chemists and chemical engineers to address the challenges and promises offered by this therapeutic approach.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/metabolismo , Glucose/metabolismo , Insulina/metabolismo , Insulina/uso terapêutico , Humanos , Modelos Biológicos
10.
Nat Chem ; 10(1): 109, 2017 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-29256502

RESUMO

This corrects the article DOI: 10.1038/nchem.2857.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA