Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Community Eye Health ; 32(106): 28-30, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31649426
2.
Eye (Lond) ; 38(9): 1702-1706, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38454172

RESUMO

BACKGROUND/OBJECTIVES: The aim of this study was to investigate whether the use of the silicone tipped irrigation/aspiration (I/A) handpiece CapsuleGuard® (Bausch + Lomb, Laval, Canada) reduced rates of posterior capsule rupture (PCR) during cataract surgery. METHODS: Royal College of Ophthalmologists' National Ophthalmology Database (NOD) Cataract Audit data from 01/04/2010 and 31/03/2021 and Bausch + Lomb sales figures were combined to identify centres participating in national cataract audit who have routinely adopted the silicone tipped I/A handpiece, CapsuleGuard®. Data were included only from centres with eligible cataract operations recorded on the NOD both before and after adopting CapsuleGuard®. Review of the literature was undertaken to estimate the proportion of PCR that occurs during I/A, to evaluate the impact of adoption of CapsuleGuard® on PCR occurring in this phase of surgery. RESULTS: Within the study period, 267 371 eligible cataract operations were performed in 14 centres with >50 eligible operations both before and after adopting CapsuleGuard®. Within centres adopting CapsuleGuard®, the rate of PCR occurrence reduction was 16.4%. Before and after the adoption of CapsuleGuard® the median change of PCR was 21.7% reduction (IQR: 4.8% to 37.7% reduction). CONCLUSIONS: A reduction in the rate of PCR was seen after regular adoption of CapsuleGuard® during cataract operations. Review of published studies attributing PCR to various components of the cataract operation suggest around 25% of PCR may occur during I/A; adoption of CapsuleGuard may, therefore, be associated with avoidance of a substantial proportion of the PCR during that phase of surgery.


Assuntos
Extração de Catarata , Bases de Dados Factuais , Oftalmologia , Ruptura da Cápsula Posterior do Olho , Humanos , Extração de Catarata/estatística & dados numéricos , Ruptura da Cápsula Posterior do Olho/epidemiologia , Ruptura da Cápsula Posterior do Olho/etiologia , Oftalmologia/estatística & dados numéricos , Masculino , Reino Unido/epidemiologia , Feminino , Irrigação Terapêutica/estatística & dados numéricos , Idoso
3.
Eye (Lond) ; 37(8): 1633-1639, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36002508

RESUMO

BACKGROUND/OBJECTIVES: Posterior Capsule Opacification (PCO) is the most common long-term post-operative adverse occurrence after cataract surgery often requiring treatment with YAG laser posterior capsulotomy. This study aimed to identify potential risk factors, known at the time of cataract surgery, that influence the development of PCO. SUBJECT/METHODS: A retrospective study of publicly funded cataract surgery from The Royal College of Ophthalmologists' National Ophthalmology Database. Eligible for analysis were 500,872 cataract operations performed in 41 participating centres. RESULTS: The 500,872 operations were performed on 243,167 (48.5%) left eyes and 257,705 (51.5%) right eyes from 373,579 patients by 2196 surgeons. Post-cataract PCO was recorded for 61,778 (12.3%) eyes and the six month, one, three, five and nine year observed rates of PCO were 2.3%, 4.4%, 19.7%, 34.0% and 46.9% respectively. Different PCO profiles were observed between IOL materials and the identified risk factors that increased the risk of developing PCO included hydrophilic IOL material, axial length >26 mm, the presence of high myopia and implantation of lower IOL powers and previous vitrectomy surgery, along with younger age and female gender. CONCLUSIONS: Many factors influence the development of PCO relating to the patient, the eye, the lens and the surgery. Some factors are modifiable such as IOL material, therefore the opportunity exists to attempt to reduce PCO rates, benefitting patients and the UK NHS.


Assuntos
Opacificação da Cápsula , Catarata , Cápsula do Cristalino , Lentes Intraoculares , Oftalmologistas , Oftalmologia , Humanos , Feminino , Opacificação da Cápsula/epidemiologia , Opacificação da Cápsula/etiologia , Opacificação da Cápsula/cirurgia , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Estudos Retrospectivos , Cápsula do Cristalino/cirurgia , Catarata/etiologia , Fatores de Risco , Complicações Pós-Operatórias/etiologia
4.
BMJ Open ; 12(8): e053560, 2022 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-35985773

RESUMO

OBJECTIVES: To describe the relationships between axial length and intraoperative complications in patients undergoing cataract surgery. DESIGN: Cohort analysis of the Royal College of Ophthalmologists' National Ophthalmology Database (RCOphth NOD). SETTING: 110 National Health Service Trusts in England, Health Boards in Wales, Independent Sector Treatment Centres and Guernsey. PARTICIPANTS: 820 354 patients, aged 18 years or older, undergoing cataract surgery. Eligible operations were those from centres with at least 50 operations with a recorded axial length measurement and age at surgery between 1 April 2010 and 31 August 2019. INTERVENTIONS: Phacoemulsification where the primary intention was cataract surgery alone. OUTCOME MEASURES: Posterior capsule rupture (PCR) and other recorded intraoperative complications. RESULTS: 1 211 520 eligible operations were performed by 3210 surgeons. The baseline axial length was <21 mm (short eyes) for 17 170 (1.4%) eyes, 21-28 mm (medium eyes) for 1 182 513 (97.6%) eyes and >28 mm (long eyes) for 11 837 (1.0%) eyes. The median age at surgery was younger for patients with long eyes than those with short or medium eyes. The rate of any intraoperative complication was higher for short eyes than medium or long with complication rates of 4.5%, 2.9% and 3.3%, respectively (p<0.001). PCR occurred in 1.40% surgeries overall, and in 1.53%, 1.40% and 1.61% of short, medium and long eyes, respectively (p=0.043, not significant at the 1% level). CONCLUSIONS: Overall PCR rates for cataract surgery in RCOphth NOD contributing centres are lower than previously reported and there is little change in PCR rates by axial length. Short eyes were more likely to have an intraoperative complication than medium or long eyes.


Assuntos
Extração de Catarata , Catarata , Oftalmologistas , Oftalmologia , Facoemulsificação , Catarata/epidemiologia , Extração de Catarata/efeitos adversos , Estudos de Coortes , Humanos , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Estudos Retrospectivos , Medicina Estatal , Acuidade Visual
5.
J Neurosci ; 30(22): 7613-23, 2010 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-20519536

RESUMO

Preventing and reversing opioid dependence continues to be a clinical challenge and underlying mechanisms of opioid actions remain elusive. We report that matrix metalloproteinase-9 (MMP-9) in the spinal cord contributes to development of physical dependence on morphine. Chronic morphine exposure and naloxone-precipitated withdrawal increase activity of spinal MMP-9. Spinal inhibition or targeted mutation of MMP-9 suppresses behavioral signs of morphine withdrawal and the associated neurochemical alterations. The increased MMP-9 activity is mainly distributed in the superficial dorsal horn and colocalized primarily with neurons and small numbers of astrocytes and microglia. Morphine exposure and withdrawal increase phosphorylation of NR1 and NR2B receptors, ERK1/2, calmodulin-dependent kinase II, and cAMP response element binding proteins; and such phosphorylation is suppressed by either spinal inhibition or targeted mutation of MMP-9. Further, spinal administration of exogenous MMP-9 induces morphine withdrawal-like behavioral signs and mechanical allodynia, activates NR1 and NR2 receptors, and downregulates integrin-beta1, while a function-neutralizing antibody against integrin-beta1 suppresses MMP-9-induced phosphorylation of NR1 and NR2B. Morphine withdrawal-induced MMP-9 activity is also reduced by an nNOS inhibitor. Thus, we hypothesize that spinal MMP-9 may contribute to the development of morphine dependence primarily through neuronal activation and interaction with NR1 and NR2B receptors via integrin-beta1 and NO pathways. The other gelatinase, MMP-2, is not involved in morphine dependence. Inhibiting spinal MMP-9 or MMP-2 reduces chronic and/or acute morphine tolerance. This study suggests a novel therapeutic approach for preventing, minimizing, or reversing opioid dependence and tolerance.


Assuntos
Metaloproteinase 9 da Matriz/metabolismo , Dependência de Morfina/patologia , Dependência de Morfina/fisiopatologia , Medula Espinal/enzimologia , Animais , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Interações Medicamentosas , Tolerância a Medicamentos/fisiologia , Inibidores Enzimáticos/farmacologia , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Regulação da Expressão Gênica/fisiologia , Hiperalgesia/fisiopatologia , Masculino , Metaloproteinase 9 da Matriz/deficiência , Metaloproteinase 9 da Matriz/farmacocinética , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Morfina/efeitos adversos , Dependência de Morfina/tratamento farmacológico , Naloxona/uso terapêutico , Antagonistas de Entorpecentes/uso terapêutico , Entorpecentes/efeitos adversos , Proteínas do Tecido Nervoso/genética , Proteínas do Tecido Nervoso/metabolismo , Limiar da Dor/efeitos dos fármacos , Limiar da Dor/fisiologia , Medula Espinal/efeitos dos fármacos , Medula Espinal/patologia , Fatores de Tempo
6.
Br J Ophthalmol ; 104(3): 324-329, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31142463

RESUMO

OBJECTIVE: To investigate the impact of EyeSi surgical simulators on posterior capsule rupture (PCR) rates of cataract surgery performed by first and second year trainee surgeons. DESIGN: A Royal College of Ophthalmologists' National Ophthalmology Database audit study of first and second year surgeons' PCR rates over seven consecutive National Health Service (NHS) years. Participating centres were contacted to ascertain the date when their surgeons had access to an EyeSi machine and whether this was on-site or off-site. Operations were classified as before, after or no access to EyeSi. SETTING: The study took place in 29 NHS Ophthalmology Units in a secondary care setting. RESULTS: Two-hundred and sixty five first and second year trainee surgeons performed 17 831 cataract operations. 6919 (38.8%) operations were performed before access to an EyeSi, 8648 (48.5%) after access to an EyeSi and 2264 (12.7%) operations by surgeons with no access to an EyeSi. Overall, there was a 38% reduction in the first and second year surgeon's unadjusted PCR rates from 4.2% in 2009 to 2.6% in 2015 for surgeons with access to an EyeSi, and a 3% reduction from 2.9% to 2.8% for surgeons without access to an EyeSi. The overall first and second year unadjusted PCR rates for before, after and no access to EyeSi were 3.5%, 2.6% and 3.8%, respectively. The decrease in the with-access to an EyeSi group PCR rate was similar for surgeons with access to an EyeSi 'on site' or 'off site'. CONCLUSIONS: First and second year trainee surgeons' unadjusted PCR rates have decreased since 2009 which has significant benefits for patients undergoing cataract surgery. This 38% reduction in complication rates aligns with the introduction of EyeSi simulator training.


Assuntos
Extração de Catarata/estatística & dados numéricos , Educação de Pós-Graduação em Medicina/métodos , Internato e Residência/métodos , Oftalmologia/educação , Treinamento por Simulação/métodos , Sociedades Médicas , Realidade Virtual , Extração de Catarata/educação , Competência Clínica , Avaliação Educacional , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA