Med Phys ; 38(8): 4894-902, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21928661

RESUMO

PURPOSE: To mathematically model the relationship between CT measurements of emphysema obtained from images reconstructed using different section thicknesses and kernels and to evaluate the accuracy of the models for converting measurements to those of a reference reconstruction. METHODS: CT raw data from the lung cancer screening examinations of 138 heavy smokers were reconstructed at 15 different combinations of section thickness and kernel. An emphysema index was quantified as the percentage of the lung with attenuation below -950 HU (EI950). Linear, quadratic, and power functions were used to model the relationship between EI950 values obtained with a reference 1 mm, medium smooth kernel reconstruction and values from each of the other 14 reconstructions. Preferred models were selected using the corrected Akaike information criterion (AICc), coefficients of determination (R2), and residuals (conversion errors), and cross-validated by a jackknife approach using the leave-one-out method. RESULTS: The preferred models were power functions, with model R2 values ranging from 0.949 to 0.998. The errors in converting EI950 measurements from other reconstructions to the 1 mm, medium smooth kernel reconstruction in leave-one-out testing were less than 3.0 index percentage points for all reconstructions, and less than 1.0 index percentage point for five reconstructions. Conversion errors were related in part to image noise, emphysema distribution, and attenuation histogram parameters. Conversion inaccuracy related to increased kernel sharpness tended to be reduced by increased section thickness. CONCLUSIONS: Image reconstruction-related differences in quantitative emphysema measurements were successfully modeled using power functions.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/normas , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Modelos Estatísticos , Reprodutibilidade dos Testes
2.
J Comput Assist Tomogr ; 34(5): 773-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20861785

RESUMO

OBJECTIVE: To evaluate the use of inflation-fixed lung tissue for emphysema quantification with computed tomography (CT) and He magnetic resonance (MR) diffusion imaging. METHODS: Fourteen subjects representing a range of chronic obstructive pulmonary disease severity who underwent complete or lobar lung resection were studied. Computed tomographic measurements of lung attenuation and MR measurements of the hyperpolarized 3He apparent diffusion coefficient (ADC) in resected specimens fixed in inflation with heated formalin vapor were compared with measurements obtained before fixation. RESULTS: The mean (SD) CT emphysema indices were 56% (17%) before and 58% (19%) after fixation (P = 0.77; R = 0.76). Index differences correlated with differences in lung volume (R = 0.47). The mean (SD) 3He ADCs were 0.40 (0.15) cm/s before and 0.39 (0.14) cm/s after fixation (P = 0.03, R = 0.98). The CT emphysema index and the 3He ADC were correlated before (R = 0.89) and after fixation (R = 0.79). CONCLUSIONS: Concordance of CT and 3He MR imaging measurements in unfixed and inflation-fixed lungs supports the use of inflation-fixed lungs for quantitative imaging studies in emphysema.


Assuntos
Enfisema/diagnóstico , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Enfisema/diagnóstico por imagem , Enfisema/cirurgia , Feminino , Hélio , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Pneumonectomia , Doses de Radiação
3.
Radiology ; 248(2): 655-61, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18641256

RESUMO

PURPOSE: To evaluate the safety of hyperpolarized helium 3 ((3)He) magnetic resonance (MR) imaging. MATERIALS AND METHODS: Local institutional review board approval and informed consent were obtained. Physiologic monitoring data were obtained before, during, and after hyperpolarized (3)He MR imaging in 100 consecutive subjects (57 men, 43 women; mean age, 52 years +/- 14 [standard deviation]). The subjects inhaled 1-3 L of a gas mixture containing 300-500 mL (3)He and 0-2700 mL N(2) and held their breath for up to 15 seconds during MR imaging. Heart rate and rhythm and oxygen saturation of hemoglobin as measured by pulse oximetry (Spo(2)) were monitored continuously throughout each study. The effects of (3)He MR imaging on vital signs and Spo(2) and the relationship between pulmonary function, number of doses, and clinical classification (healthy volunteers, patients with asthma, heavy smokers, patients undergoing lung volume reduction surgery for severe emphysema, and patients with lung cancer) and the lowest observed Spo(2) were assessed. Any subjective symptoms were noted. RESULTS: Except for a small postimaging decrease in mean heart rate (from 78 beats per minute +/- 13 to 73 beats per minute +/- 11, P < .001), there was no effect on vital signs. A mean transient decrease in Spo(2) of 4% +/- 3 was observed during the first minute after gas inhalation (P < .001) in 77 subjects who inhaled a dose of 1 L for 10 seconds or less, reaching a nadir of less than 90% at least once in 20 subjects and of less than 85% in four subjects. There was no correlation between the lowest Spo(2) and pulmonary function parameters other than baseline Spo(2) (r = 0.36, P = .001). The lowest mean Spo(2) varied by 1% between the first and second and second and third doses (P < .001) and was unrelated to clinical classification (P = .40). Minor subjective symptoms were noted by 10 subjects. No serious adverse events occurred. CONCLUSION: Hyperpolarized (3)He MR imaging can be safely performed in healthy subjects, heavy smokers, and those with severe obstructive airflow limitation, although unpredictable transient desaturation suggests that potential subjects should be carefully screened for comorbidities.


Assuntos
Hélio , Pneumopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Monitorização Fisiológica/métodos , Idoso , Análise de Variância , Feminino , Frequência Cardíaca/fisiologia , Hélio/efeitos adversos , Humanos , Pneumopatias/cirurgia , Masculino , Pessoa de Meia-Idade , Oximetria , Segurança
4.
Acad Radiol ; 17(2): 146-56, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19931472

RESUMO

RATIONALE AND OBJECTIVES: Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement. MATERIALS AND METHODS: Low-radiation-dose multidetector CT was performed in 21 subjects representing a wide range of emphysema severity. Images were reconstructed using 20 different combinations of section thickness and reconstruction kernel. Emphysema index values were determined as the percentage of lung pixels having attenuation lower than multiple thresholds ranging from -960 HU to -890 HU. The index values obtained from the different thickness-kernel combinations were compared by repeated measures analysis of variance and Bland-Altman plots of mean versus difference in all subjects, and correlated with quantitative histology (mean linear intercept, Lm) in a subset of resected lung specimens. RESULTS: The effects of section thickness and reconstruction kernel on the emphysema index were significant (P < .001) and diminished as the index attenuation threshold was raised. The changes in index values from changing the thickness-kernel combination were largest for subjects with intermediate index values (10%-30%), and became progressively smaller for those with lower and higher index values. This pattern was consistent regardless of the thickness-kernel combinations compared and the HU threshold used. Correlations between the emphysema index values obtained with each thickness-kernel combination and Lm ranged from r = 0.55-0.68 (P = .007-.03). CONCLUSION: The effects of CT section thickness and kernel on emphysema index values varied systematically with the magnitude of the emphysema index. All reconstruction techniques provided significant correlations with quantitative histology.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Enfisema Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Magn Reson Imaging ; 30(4): 801-8, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19787725

RESUMO

PURPOSE: To characterize the effect of diffusion time on short-range hyperpolarized (3)He magnetic resonance imaging (MRI) diffusion measurements across a wide range of emphysema severity. MATERIALS AND METHODS: (3)He diffusion MRI was performed on 19 lungs or lobes resected from 18 subjects with varying degrees of emphysema using three diffusion times (1.6 msec, 5 msec, and 10 msec) at constant b value. Emphysema severity was quantified as the mean apparent diffusion coefficient (ADC) and as the percentage of pixels with ADC higher than multiple thresholds from 0.30-0.55 cm(2)/sec (ADC index). Quantitative histology (mean linear intercept) was obtained in 10 of the lung specimens from 10 of the subjects. RESULTS: The mean ADCs with diffusion times of 1.6, 5.0, and 10.0 msec were 0.46, 0.40, and 0.37 cm(2)/sec, respectively (P < 0.0001, analysis of variance [ANOVA]). There was no relationship between the ADC magnitude and the effect of diffusion time on ADC values. The mean linear intercept correlated with ADC (r = 0.91-0.94, P < 0.001) and ADC index (r = 0.78-0.92, P < 0.01) at all diffusion times. CONCLUSION: Decreases in ADC with longer diffusion time were unrelated to emphysema severity. The strong correlations between the ADC at all diffusion times tested and quantitative histology demonstrate that ADC is a robust measure of emphysema.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Enfisema Pulmonar/patologia , Idoso , Análise de Variância , Feminino , Hélio , Humanos , Técnicas In Vitro , Isótopos , Masculino